5-11
Address
Remark
Initial value
NTSC PAL
B4
B5
B6
B7
B8
B9
BA
BB to C1
C2
C3 to C5
C6
C7
C8
C9 to CB
CC
CD to D0
D1
D2 to D5
D6
D7
D8 to D9
DA
DB
DC
DD
DE to DF
E0
E1
E2
E3
E4 to FF
D0
26
CE
1E
D0
26
CE
1E
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Touch panel adj.
Fixed data-1
Table. 5-1-3.
5. 8  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
Table. 5-1-4.
Address
Remark
00 to 52
53
54 to 59
5A
5B
5C to 98
99
9A to A7
A8
A9 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5-12
1-2-2.
INITIALIZATION OF B PAGE DATA
(DCR-PC5/PC5E)
Note:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Switch setting:
POWER ................................................................. MEMORY
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
8F
02
Set the data, and press PAUSE
button.
3
2
8F
03
Set the data, and press PAUSE
button.
4
2
8F
02
Set the data, and press PAUSE
button.
5
2
8F
00
Set the data, and press PAUSE
button.
6
5
0E
00
Set the data, and press PAUSE
button.
7
5
01
F3
Set the data, and press PAUSE
button.
8
5
00
01
Set the data, and press PAUSE
button.
9
5
0E
Check that the data changes to
“01”.
10
Perform “Modification of B
Page Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
2
8F
02
Set the data, and press PAUSE
button.
2
2
8F
03
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
00
Set the data, and press PAUSE
button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
3. B  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”.)
Table. 5-1-5.
Address
Remark
00 to 13
14
15
16
17
18
19
1A to 4F
50
51 to 53
54
55 to 6F
70
71 to FF
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5-13
1-2-3.
INITIALIZATION OF E, F, 7 PAGE DATA
1. Initializing the E, F, 7 Page Data
Note1:
If “Initializing the E, F, 7 Page Data” is performed, all data of the
E page, F page and 7 page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 7 page data
2) Camera system adjustments
3) IR transmitter adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to 59
Switch setting:
POWER .................................................................. CAMERA
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
Set the following data, and press
PAUSE button.
2D: DCR-PC5 (NTSC)
2F: DCR-PC4E/PC5E (PAL)
3
6
03
01
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”.
5
Perform “Modification of E, F, 7
Page Data”.
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 7 Page data
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn off the power and turn on again.
3. F  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
00 to 0F
10 to 11
12
13
14 to 16
17
18
19
1A to 1C
1D
1E
1F
20 to 30
30
31
32
33
34
35
36
37
38 to 3B
3C
3D
3E to 3F
40
41
42 to 49
4A
4B
4C
4D
4E
4F
50
51
52 to 59
5A
5B
5C
5D
5E
5F
60 to 65
66
67
68
69
6A to 6F
70
80
80
81
A0
17
9A
80
7A
90
3E
43
59
22
27
00
F1
80
40
51
19
22
20
93
13
00
00
46
00
19
00
2A
00
00
C4
Fixed data-1
36MHz origin osc adj.
Zoom key center adj.
Fixed data-1
HALL adj.
Fixed data-1
Max gain adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Fixed data-1
Flange back adj.
Fixed data-1
Flange back adj.
Fixed data-1
Fixed data-2
Fixed data-1
Optical axis adj.
Fixed data-1
Mechanical shutter adj.
80
80
81
A0
17
9A
80
7A
90
3E
43
59
22
24
00
EF
80
40
51
19
22
20
93
13
00
00
46
00
19
00
2A
00
00
C4
Address
Remark
Initial value
NTSC PAL
5-14
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85 to 8D
8E
8F
90 to 9E
9F
A0 to AF
B0
B1
B2 to B3
B4
B5 to D0
D1
D2 to D4
D5
D6 to DC
DD
DE to FF
Address
0E
75
0C
26
0B
35
0A
6E
09
A5
61
A1
79
64
81
82
84
B5
7B
20
0E
75
0C
26
0B
35
0A
6E
09
A5
61
A1
79
64
81
82
84
B5
7B
20
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Remark
Initial value
NTSC PAL
Table. 5-1-6.
4. E  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Table. 5-1-7.
00 to 64
65
66 to 69
6A
6B to 71
72
73
74 to 7E
7F
80 to 83
84
85
86
87
88 to 8B
8C
8D to 8E
8F
90
91
92 to 94
95
96 to 97
98
99 to AF
B0
B1
B2
B3
B4
B5
B6
B7
B8 to CE
CF
D0
D1 to DD
DE
DF to FF
Address
26
5F
24
71
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Optical axis adj.
Fixed data-1
Optical axis adj.
Fixed data-1
Remark
Initial value
NTSC PAL
Page of 127
Display

Click on the first or last page to see other DCR-PC4E / DCR-PC5 / DCR-PC5E (serv.man2) service manuals if exist.