5-7
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER (Control switch block) ............................ CAMERA
2.
NIGHT SHOT (Lens block) ............................................ OFF
3.
FUNCTION settings of the touch panel
DIGITAL EFFECT ..................................................... OFF
EXPOSURE ................................................................ OFF
MANUAL SET of the MENU settings
PROGRAM AE ................................................ AUTO
PICTURE EFFECT .............................................. OFF
WHITE BALANCE .......................................... AUTO
CAMERA SET of the MENU settings
DIGITAL ZOOM .................................................. OFF
16:9 WIDE ............................................................ OFF
STEADY SHOT ................................................... OFF
SETUP MENU of the MENU settings
DEMO MODE ...................................................... OFF
4.
FOCUS (FK-30350 block) .......................................... Manual
5.
BACK LIGHT (FK-30350 block) .................................... OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.5-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
Fig. 5-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
White
Black
841mm
1189mm
5-8
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 3F
40
41
42
43 to 48
49
4A
4B to 4C
4D
4E to 4F
50
51
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
D5
99
88
E3
A1
04
20
03
Switching position adj.
Fixed data-1
Cap FG duty adj.
Fixed data-2
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo fine adj.
Fixed data-1
APC adj.
Fixed data-1(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
1-2.
INITIALIZATION OF B, C, D, E, F, 7, 8 PAGE
DATA
1-2-1.
INITIALIZATION OF C, D, 8 PAGE DATA
1. Initializing the C, D, 8 Page Data
Note1:
If “Initializing the C, D, 8 Page Data” is performed, all data of the
C page, D page and 8 page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, D, 8 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) Color viewfinder system adjustments
6) LCD system Adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
8
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
3
81
Check that the data is “00”.
3
3
80
0A
Set the data, and press the
PAUSE button.
4
3
80
Check that the data changes to
“1A”
5
Perform “Modification of C, D,
8 Page Data”.
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the
PAUSE button.
Note:
If the following symptoms occur after completing of the
“Modification of C, D, 8 page data”, check that the data of the
“Fixed data-2” addresses of D page are same as those of the same
model of the same destination.
1) The battery end mark on the LCD or viewfinder screen is
flashing.
2) The power is shut off so that unit cannot operate.
3. C  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
5-9
52 to 63
64
65 to 85
86
87
88
89
8A to 9A
9B
9C
9D
9E
9F
A0
A1 to A2
A3
A4
A5
A6
A7
A8
A9 to AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to C1
C2
C3
C4
C5
C6
C7
C8 to CB
CC
CD to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE to E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
01
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Serial No. input
Fixed data-1
Emergency memory address
Address
Remark
Initial value
Address
Remark
Initial value
Table. 5-1-2.
5-10
4. D  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
58
59
5A
5B
5C
5D
5E to 60
61
62 to 63
64
65
66
67
68
69
6A
6B to 8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
3B
58
8F
80
80
38
5C
7E
A2
B0
08
90
6F
2D
2D
58 [4B]
3B [20]
8F
80
80
38
7E
5C
A2
B0
08
90
6F
2D
2D
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
VCO adj. (EVF)
[ ] : DCR-PC4E
Fixed data-2
Bright adj.(EVF)
Fixed data-2
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
VCO adj. (LCD)
V-COM adj. (LCD)
Bright adj. (LCD)
Black limit adj. (LCD)
Fixed data-2
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
00 to 0F
10
11 to 12
13
14
15 to 19
1A
1B to 1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 41
42
43
44
45
46 to 47
48
49
4A to 4C
4D
4E
4F
50
51
52
53
54
55
56
57
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
00
Address
Remark
Initial value
NTSC PAL
Address
Remark
Initial value
NTSC PAL
Page of 127
Display

Click on the first or last page to see other DCR-PC4E / DCR-PC5 / DCR-PC5E (serv.man2) service manuals if exist.