DOWNLOAD Sony DCR-PC110 / DCR-PC110E (serv.man4) Service Manual ↓ Size: 20.68 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-PC110 DCR-PC110E (serv.man4)
Pages
127
Size
20.68 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-pc110-dcr-pc110e-sm4.pdf
Date

Sony DCR-PC110 / DCR-PC110E (serv.man4) Service Manual ▷ View online

5-12
1-2-3.
INITIALIZATION OF E, F, 7 PAGE DATA
1. Initializing the E, F, 7 Page Data
Note1:
If “Initializing the E, F, 7 Page Data” is performed, all data of the
E page, F page and 7 page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 7 page data
2) Camera system adjustments
3) IR transmitter adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FB
Switch setting:
POWER .................................................................. CAMERA
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
Set the following data, and press
PAUSE button.
2D: DCR-PC110 (NTSC)
2F: DCR-PC110E (PAL)
3
6
03
01
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”.
5
Perform “Modification of E, F, 7
Page Data”.
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 7 Page data
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn off the power and turn on again.
3. F  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Address
Remark
Initial value
NTSC PAL
00 to 0F
10 to 11
12
13
14 to 16
17
18
19
1A
1B
1C
1D
1E
1F
20 to 2F
30
31
32
33
34
35
36
37
38 to 3B
3C
3D
3E to 3F
40
41
42 to 49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
80
80
81
5D
17
70
62
8D
80
80
7A
90
3E
43
59
22
27
00
F1
80
40
84
4A
AD
47
F0
21
80
80
40
C0
40
C0
40
C0
40
C0
8F
EF
19
00
80
80
81
5D
17
70
62
8D
80
80
7A
90
3E
43
59
22
24
00
EF
80
40
84
4A
AD
47
F0
21
80
80
40
C0
40
C0
40
C0
40
C0
8F
EF
19
00
Fixed data-1
54MHz/66MHz origin osc adj.
Zoom key center adj.
Fixed data-1
HALL adj.
Max gain adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Fixed data-1
Flange back adj.
MR adj.
Flange back adj.
5-13
4. E  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Address
Remark
Table. 5-1-7.
00 to 4F
50
51 to 8E
8F
90 to 9F
A0
A1
A2
A3
A4 to AD
AE
AF
B0 to C8
C9
CA
CB to CE
CF
D0
D1
D2
D3
D4
D5
D6 to D9
DA
DB
DC
DD
DE to EB
EC
ED
EE to F7
F8
F9
FA to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
NTSC PAL
5E
5F
60
61
62
63
64
65
66
67
68 to 6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87 to 92
93
94
95
96 to 9A
9B
9C to B9
BA
BB
BC
BD to CA
CB
CC to D4
D5
D6 to FF
1B
86
00
00
00
00
00
00
4F
52
00
00
00
10
0C
9C
09
04
08
C1
06
89
05
13
47
7F
4B
5F
47
43
3F
86
2F
1C
1B
86
00
00
00
00
00
00
5E
61
00
00
00
10
0C
9C
09
04
08
C1
06
89
05
13
47
7F
4B
5F
47
43
3F
86
2F
1C
Flange back adj.
Angular velocity sensor sensitivity adj.
Fixed data-1
IR audio deviation adj.
IR video deviation adj.
IR video carrier frequency adj.
Fixed data-1
Mechanical shutter adj.
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-6.
5-14
5. 7  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Address
Remark
Initial value
NTSC PAL
Address
Remark
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14
15 to 1C
1D
1E
1F
20
21 to 32
33
34
35
36
37
38 to 39
3A
3B to 3C
3D
3E
3F
40 to 48
49
4A to 67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A to B8
B9
BA to C5
C6
C7 to C9
CA
CB to CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8 to D9
DA
DB
DC
DD
DE
DF
E0
E1
E2 to EA
EB
EC to EF
F0
F1
F2
F3
F4 to F7
F8
F9
FA
FB
7A
84
81
86
35
20
80
27
78
7A
84
81
86
35
20
80
27
78
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Mechanical shutter adj
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Strobe light level adj. for movie mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Strobe light level adj.
Strobe white balance adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Table. 5-1-8.
5-15
Fig. 5-1-6.
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
Note:
NTSC model: DCR-PC110
PAL model: DCR-PC110E
1. 54MHz/66MHz Origin Oscillation Adjustment
(CD-285 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin wd of IC754 on VC-253 board or
Pin 8 of IC652 on VC-253 board
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
13500000 ± 68Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the
frequency (f) to the specified
value.
3
F
12
Press PAUSE button.
4
0
01
00
Set the data.
2. Zoom Key Center Adjustment
Set the A/D value center of the microprocessor to the center voltage
of the zoom key.
If deviated, the zoom lens operates of itself ,even if the zoom key is
the center position.
Subject
Not required
Measurement Point
Display data of page: 6, address: 50
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13
Note:
Don’t touch the zoom lever during adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
50
Read the data, and this data is
named D
50
.
3
F
13
D
50
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
IC754
48
37
36
25
24
13
12
1
IC652
11
20
1
10
VC-253 board (SIDE B)
Page of 127
Display