DOWNLOAD Sony DCR-PC110 / DCR-PC110E (serv.man4) Service Manual ↓ Size: 20.68 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-PC110 DCR-PC110E (serv.man4)
Pages
127
Size
20.68 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-pc110-dcr-pc110e-sm4.pdf
Date

Sony DCR-PC110 / DCR-PC110E (serv.man4) Service Manual ▷ View online

5-8
1-2.
INITIALIZATION OF B, C, D, E, F, 7, 8 PAGE
DATA
1-2-1.
INITIALIZATION OF C, D, 8 PAGE DATA
1. Initializing the C, D, 8 Page Data
Note1:
If “Initializing the C, D, 8 Page Data” is performed, all data of the
C page, D page and 8 page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, D, 8 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) Color viewfinder system adjustments
6) LCD system Adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
8
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data
2
3
81
Check that the data is “00”.
3
3
80
0A
Set the data, and press the
PAUSE button.
4
3
80
Check that the data changes to
“1A”
5
Perform “Modification of C, D,
8 Page Data”.
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the
PAUSEbutton.
Note:
If the following symptoms occur after completing of the
“Modification of C, D, 8 page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
3. C  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
Address
Remark
Initial value
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 3F
40
41 to 42
43
44 to 4B
4C
4D
4E to 4F
50
51
52 to 83
84
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
Switching position adj.
Fixed data-1
Cap FG duty adj.
Fixed data-2
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo fine adj.
Fixed data-1
APC adj.
Fixed data-1(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5-9
Address
Remark
Initial value
Address
Remark
Initial value
85
86
87
88
89
8A to 9A
9B
9C
9D
9E
9F
A0
A1 to A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to BF
C0
C1 to C7
C8
C9 to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0 to E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
01
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Emergency memory address
Table. 5-1-2.
5-10
4. D  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
5. 8  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
Address
Remark
Table. 5-1-4.
Address
Remark
Initial value
NTSC PAL
00 to 52
53
54 to 74
75
76 to 8F
90
91 to 98
99
9A to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00 to 0F
10
11 to 12
13
14
15 to 26
27
28 to 2F
30
31 to 43
44
45
46 to 51
52
53
54
55 to 57
58
59
5A to 67
68
69 to 91
92
93
94
95
96
97
98
99
9A to A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC to B9
BA
BB to C5
C6
C7 to D0
D1
D2 to D5
D6
D7
00
3B
58
8F
80
80
1B
5C
7E
A2
B0
08
80
80
20
23
00
58
3B
98
80
80
1B
5C
7E
A2
B0
08
80
80
20
23
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
VCO adj. (EVF)
Fixed data-1
Bright adj.(EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
VCO adj. (LCD)
V-COM adj. (LCD)
Bright adj. (LCD)
Black limit adj. (LCD)
Fixed data-1
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Address
Remark
Initial value
NTSC PAL
D8 to D9
DA
DB to FF
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-3.
5-11
Address
Remark
Table. 5-1-5.
1-2-2.
INITIALIZATION OF B PAGE DATA
Note:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Switch setting:
POWER ................................................................  MEMORY
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
8F
02
Set the data, and press PAUSE
button.
3
2
8F
03
Set the data, and press PAUSE
button.
4
2
8F
02
Set the data, and press PAUSE
button.
5
2
8F
00
Set the data, and press PAUSE
button.
6
5
01
F3
Set the data, and press PAUSE
button.
7
5
00
01
Set the data, and press PAUSE
button.
8
5
02
Check that the data is “00”.
9
Perform “Modification of B
Page Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
2
8F
02
Set the data, and press PAUSE
button.
2
2
8F
03
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
00
Set the data, and press PAUSE
button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
3. B  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”.)
00 to 18
19
1A to 54
55
56 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Page of 127
Display

Click on the first or last page to see other DCR-PC110 / DCR-PC110E (serv.man4) service manuals if exist.