Sony DCR-PC103E / DCR-PC104E / DCR-PC105 / DCR-PC105E (serv.man2) Service Manual ▷ View online
2-3
DCR-PC103E/PC104E/PC105/PC105E
2-2. CABINET (FRONT) ASSEMBLY
2-3. CABINET (G) ASSEMBLY
4
Open the cassette lid.
2
Open the jack cover
7
Cabinet (front) assembly
6
Two Claws
5
Screw
(M1.7
×
2.5),
lock ace, p2
3
Screw
(M1.7
×
2.5),
lock ace, p2
1
Screw (M1.7
×
4),
lock ace, p2 (black)
Flexible board
(from the lens device)
(from the lens device)
Flexible board
(from the NS-018 board)
(from the NS-018 board)
Caution
Caution
When attaching the cabinet
(front) assembly, be careful
not to damage the claw.
(front) assembly, be careful
not to damage the claw.
When installing the cabinet
(front) assembly, install it while
pushing the flexible boards
(from the lens device and the
NS-018 board) in the direction
of the arrow.
(front) assembly, install it while
pushing the flexible boards
(from the lens device and the
NS-018 board) in the direction
of the arrow.
Be careful not to drop the eject knob.
A
5
Float the cabinet (G) assembly
and remove the eject knob
from the hole of the Cabinet
(G) assembly.
from the hole of the Cabinet
(G) assembly.
7
Claw
Eject knob
8
Eject knob
3
Open the jack
cover (HP)
6
Remove the cabinet (G) assembly
in the direction of the arrow
A
.
1
Three screws
(M1.7
×
2.5),
lock ace, p2
2
Two screws
(M1.7
×
2.5),
lock ace, p2
4
Open the cassette lid.
Caution
2-4
DCR-PC103E/PC104E/PC105/PC105E
2-5. ST CABINET (UPPER) ASSEMBLY
2-4. CABINET (L)
5
Cabinet (L)
6
Jack cover (L) assembly
2
Flip over the jack cover
(L) assembly.
4
Three screws
(M1.7
×
2.5),
lock ace, p2
3
Screw
(M1.7
×
2.5),
lock ace, p2
1
Screw
(M1.7
×
4),
lock ace, p2
1
Push the portion
A
in the
direction of the arrow to open
the Flash.
the Flash.
Short jig (R: 1k
Ω
/1W)
A
K
3
EG grip
(M1.7
×
2.5)
2
EG grip
(M1.7
×
2.5)
6
ST cabinet (upper)
assembly
3
ST cabinet (N)
assembly
5
Two claws
4
Two claws
Caution
Note: The power supply capacitor of the flash unit is charged to the high tension
voltage as high as 300 V at a maximum. You will get electrical shock when
you touch the terminal of the charged capacitor . The charged potential
remains even after the main power of the machine is turned off. Discharge
the remaining power in the capacitor referring to Service Note
(See page 1-2). High-voltage cautions. Short jig (R: 1k
voltage as high as 300 V at a maximum. You will get electrical shock when
you touch the terminal of the charged capacitor . The charged potential
remains even after the main power of the machine is turned off. Discharge
the remaining power in the capacitor referring to Service Note
(See page 1-2). High-voltage cautions. Short jig (R: 1k
Ω
/1W)
1
EG grip
(M1.7
×
2.5)
2
EG grip
(M1.7
×
2.5)
(PC103E/PC104E)
(PC105/PC105E)
A
Xenon tube
Accessory shoe GND
2-5
DCR-PC103E/PC104E/PC105/PC105E
4
Remove the connector.
1
Screw
(M1.7
×
2.5),
lock ace, p2
7
Screw
(M1.7
×
4),
lock ace, p2
8
Screw
(M1.7
×
2.5),
lock ace, p2
6
Three screws
(M1.7
×
2.5),
lock ace, p2
5
Open the LCD unit.
2
Two claws
3
CPC lid
9
Cabinet (R) section
Caution
When installing the cabinet (R) section, install
it while the LCD unit is in the opened condition.
it while the LCD unit is in the opened condition.
2-6. CABINET (R) SECTION
2-6
DCR-PC103E/PC104E/PC105/PC105E
2-7. BATTERY HOLDER
4
Screw
6
Battery bracket
5
Radiation sheet (R)
7
Flip over the BJ-004 board.
8
Battery holder
Radiation sheet (R)
Battery bracket
1
Two screws
(M1.7
×
2.5),
lock ace, p2
2
Four screws (M1.7
×
4),
lock ace, p2
3
Screw
(M1.7
×
2.5),
lock ace, p2
Caution
Click on the first or last page to see other DCR-PC103E / DCR-PC104E / DCR-PC105 / DCR-PC105E (serv.man2) service manuals if exist.