DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ↓ Size: 989.95 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man4)
Pages
70
Size
989.95 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc90-dcr-hc90e-sm4.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ▷ View online

6-62
DCR-HC90/HC90E
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
B
Example: If “8E” is displayed on the adjustment remote commander, the
bit values for bit7 to bit4 are shown in the A column, and the
bit values for bit3 to bit0 are shown in the B column.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
4. Bit value discrimination
Bit values must be discriminated using the display data of the
adjustment remote commander for following items. Use the table
below to discriminate if the bit value is “1” or “0”.
A
5. Switch check (1)
Page 2
Address 81
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 2, address: 81.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
6. Switch check (2)
Page 7
Address 4F
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 4F.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
0
1
3
4
5
Function
POWER SW (XPOWER SW) (SS11600 block)
MODE SW (XMODE SW) (SS11600 block)
EJECT SW (XEJECT SW) (SS11600 block S8502)
CC DOWN SW (Mechanism chassis)
DISPLAY/BATTERY INFO LCD BACKLIGHT SW (XBATT INFO SW)
(EZ11600 block S002)
When bit value=1
ON
ON
ON
ON (DOWN)
ON
When bit value=0
OFF
OFF
OFF
OFF (UP)
OFF
Bit
4
Function
REC PROOF SW (Mechanism chassis)
When bit value=1
SAVE
When bit value=0
REC
7. Switch check (3)
Page 7
Address F3
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F3.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
0
Function
A/V jack (Multi jack) (JK-280 board CN8101)
When bit value=1
Used
When bit value=0
Not used
6-63
DCR-HC90/HC90E
8. Switch check (4)
Page 7
Address 65 to 6A
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 65 to 6A.
2)
By discriminating the display data, the pressed key can be discriminated.
Data
Address
65
(KEY AD0)
(IC5101 <zc. )
66
(KEY AD1)
(IC5101 <zv/ )
67
(KEY AD2)
(IC5101 <zvz )
68
(KEY AD3)
(IC5101 <zvx )
69
(KEY AD4)
(IC5101 <zvc )
6A
(KEY AD5)
(IC5101 <zvv )
00
(00 to 0C)
START/STOP
(SS11600 block)
(S8501)
PHOTO REC
(ZM11600 block)
(S8601)
PANEL OPEN
(FP-063 flexible)
(S001)
PANEL REVERSE
(FP-066 flexible)
(S001)
REC START/STOP
(SB9000 block)
(S8703)
EASY
(EZ11600 block)
(S003)
1B
(0D to 27)
PHOTO FREEZE
(ZM11600 block)
(S8602)
ZOOM WIDE
(SB9000 block)
(S8701)
BACK LIGHT
(EZ11600 block)
(S001)
36
(28 to 44)
WIDE (4:3/16:9)
(SS11600 block)
(S8504)
ZOOM TELE
(SB9000 block)
(S8702)
77
(65 to 8A)
NIGHT SHOT ON
(LD-176 board)
(S3801)
FF
(E7 to FF)
No key input
NIGHT SHOT OFF
(LD-176 board)
(S3801)
PANEL CLOSE
(FP-063 flexible)
(S001)
PANEL NORMAL
(FP-066 flexible)
(S001)
No key input
No key input
53
(45 to 64)
FLASH
(SS11600 block)
(S8503)
9. Lens barrier check
Page 3
Address 68
Page 6
Address 62
Note: The data of page: 0, address: 10 must be “00”.
Page
3
6
Using method:
1)
Set up the CAMERA-TAPE mode (or CAMERA-MEMORY mode).
2)
By discriminating the bit values of page: 3, address: 68, the state of the lens barrier can be discriminated.
3)
Check that the data of page: 6, address: 62 is “01”. If the data is other than “01”, the operation has errors.
4)
Set up the PLAY/EDIT mode.
5)
By discriminating the bit values of page: 3, address: 68, the state of the lens barrier can be discriminated.
6)
Check that the data of page: 6, address: 62 is “02”. If the data is other than “02”, the operation has errors.
Address
68
62
Function
Lens barrier open/close switch
Error code
CAMERA-TAPE mode
or CAMERA-MEMORY mode
(Lens barrier: Open)
Bit1 = 1, Bit2 = 0
Data = 01
PLAY/EDIT mode
(Lens barrier: Closed)
Bit1 = 0, Bit2 = 1
Data = 02
6-64
DCR-HC90/HC90E
Count (H)
Count (M)
Count (L)
Count (H)
Count (M)
Count (L)
Hour (H)
Hour (M)
Hour (L)
Minute
Hour (H)
Hour (M)
Hour (L)
Minute
Hour (H)
Hour (M)
Hour (L)
Minute
Unloading counter
(With tape)
(BCD code)
Unloading counter
(Without tape)
(BCD code)
Power supply
operation
counted time
(BCD code)
Drum rotation
counted time
(BCD code)
Tape running
counted time
(BCD code)
10. LED check
Page 7
Address 00, 01, 04
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 01, and set data: 90.
2)
Select page: 7, address: 04, and set data: 01.
3)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
4)
Check that the following LEDs are lit.
    TALLY, CHARGE/FLASH, CAMERA-TAPE, CAMERA-MEMORY, PLAY/EDIT, MEMORY STICK, EASY OPERATION
5)
Select page: 7, address: 01, and set data: 90.
6)
Select page: 7, address: 04, and set data: 00.
7)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
8)
Select page: 7, address: 00, and set data: 00.
9)
Select page: 7, address: 01, and set data: 00.
11. Record of Use check (1)
Page 7
Address 90 to 95, A4 to AF
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A8 to AB.
Note2: This data will be kept even if the lithium battery (Control switch block (ZM11600) BT8601) is removed.
Note3: The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: 90 to 95, A4 to AF.
Initializing method:
[Unloading counter]
1)
Select page: 7, address: 90, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: 91 to 95, write data: 00 into them in same way as in address: 90.
[Power supply operation counted time]
1)
Select page: 7, address: A4, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: A5 to A7, write data: 00 into them in same way as in address: A4.
[Drum rotation counted time]
1)
Select page: 7, address: A8, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: A9 to AB, write data: 00 into them in same way as in address: A8.
[Tape running counted time]
1)
Select page: 7, address: AC, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: AD to AF, write data: 00 into them in same way as in address: AC.
Address
90
91
92
93
94
95
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Remarks
100000th place digit and 10000th place digit of count
1000th place digit and 100th place digit of count
10th place digit and 1st place digit of count
100000th place digit and 10000th place digit of count
1000th place digit and 100th place digit of count
10th place digit and 1st place digit of count
100000th place digit and 10000th place digit of count
1000th place digit and 100th place digit of count
10th place digit and 1st place digit of count
100000th place digit and 10000th place digit of count
1000th place digit and 100th place digit of count
10th place digit and 1st place digit of count
100000th place digit and 10000th place digit of count
1000th place digit and 100th place digit of count
10th place digit and 1st place digit of count
6-65
DCR-HC90/HC90E
12. Record of Use check (2)
Page 7
Address C8 to CD
Using method:
1)
The record of use data is displayed at addresses: C8 to CD.
13. Record of Self-diagnosis check
Page 7
Address B0 to C6
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
Note1: This data will be kept even if the lithium battery (Control switch block (ZM11600) BT8601) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1: “01” 
t “C”, “03” t “E”
Using method:
1)
The past self-diagnosis codes are displayed at addresses: BC to C6. Refer to the following table.
Initializing method:
1)
Select page: 7, address: 01, and set data: C0.
2)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3)
Check that the data of page: 7, address: B0 to C7 are “00”.
4)
Select page: 7, address: 00, and set data: 00.
5)
Select page: 7, address: 01, and set data: 00.
Note3: When the flash error code (E: 91: **) is displayed. After repair, clear the error flag in the following method.
1) Select page: 7, address: 01, and set data: 75.
2) Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3) Check that the data of page: 7, address: 02 is “01”.
Note1: This data will be kept even if the lithium battery (Control switch block (ZM11600) BT8601) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Page of 70
Display