DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ↓ Size: 989.95 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man4)
Pages
70
Size
989.95 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc90-dcr-hc90e-sm4.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ▷ View online

6-54
DCR-HC90/HC90E
3. S VIDEO OUT Y Level Adjustment (VC-380 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO plug of
A/V jack (75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 
±
 14mV
Note1: This adjustment should be carried out upon completion of the
following adjustments.
“IC4701 LINE OUT Y Level Adjustment”, “IC4701 LINE OUT
Chroma Level Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
4C
94
Set the data, and press PAUSE
button.
3
3
01
71
Set the data, and press PAUSE
button.
4
C
25
Change the data and set the Y
signal level (A) to the specified
value.
5
C
25
Press PAUSE button.
6
3
01
00
Set the data, and press PAUSE
button.
7
8
4C
96
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
4. S VIDEO OUT Chroma Level Adjustment
(VC-380 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V jack (75
 terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level:
A = 714 
±
 14mV (NTSC)
A = 700 
±
 14mV (PAL)
Cb level:
B = 714 
±
 14mV (NTSC)
B = 700 
±
 14mV (PAL)
Burst level: C = 286 
±
 6mV (NTSC)
C = 300 
±
 6mV (PAL)
Note1: This adjustment should be carried out upon completion of the
following adjustments.
“IC4701 LINE OUT Y Level Adjustment”, “IC4701 LINE OUT
Chroma Level Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
4C
94
Set the data, and press PAUSE button.
3
3
01
71
Set the data, and press PAUSE button.
4
C
26
Change the data and set the Cr
signal level (A) to the specified
value.
5
C
26
Press PAUSE button.
6
C
27
Change the data and set the Cb
signal level (B) to the specified
value.
7
C
27
Press PAUSE button.
8
Check that the burst signal level
(C) is satisfied the specified value.
9
3
01
00
Set the data, and press PAUSE button.
10
8
4C
96
Set the data, and press PAUSE button.
11
0
01
00
Set the data.
Fig. 6-3-6.
Fig. 6-3-7.
H
A
H
C
A
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
B
0.28 
µ
sec (NTSC) 
0.23 
µ
sec (PAL)
6-55
DCR-HC90/HC90E
5. IC4701 Automatic Adjustment
(VC-380 board)
Adjust the IC4001 Y output level (IC4701 input Y level) when letting
the IC4701 line system pass. And adjust the clamp level and output
level of the IC4701 panel (LCD) system and output level of the
IC4001.
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Display data of page: 3, address: 04,
05
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
83 to 8A, 99, A1 to A3
Specified Value
Data of page: 3, address: 04 is “78”.
Data of page: 3, address: 05 is “78”.
Note1: This adjustment should be carried out upon completion of the
following adjustments.
“IC4701 LINE OUT Y Level Adjustment”, “IC4701 LINE OUT
Chroma Level Adjustment”, “S VIDEO OUT Y Level Adjustment”
“S VIDEO OUT Chroma Level Adjustment”
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Connect the A/V cable to the A/V
jack.
2
Open the LCD panel.
3
0
01
01
Set the data.
4
3
01
78
Set the data, and press PAUSE
button.
5
3
04
Check that the data is “78”.
(Note3)
6
3
05
Check that the data is “78”.
(Note3)
7
3
01
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Note3: If the data is other than “78”, adjustment has errors. Contents of
the error is written into page: 3, addresses: 03. See the following
table.
6. VIDEO OUT Y, Chroma Level Check (VC-380 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Video plug of A/V jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 286 
±
 18mV (NTSC)
A = 300 
±
 18mV (PAL)
Burst level: B = 286 
±
 18mV (NTSC)
B = 300 
±
 18mV (PAL)
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
4C
94
Set the data, and press PAUSE
button.
3
3
01
71
Set the data, and press PAUSE
button.
4
Check that the sync signal level
(A) satisfies the specified value.
5
Check that the burst signal level
(B) satisfies the specified value.
6
3
01
00
Set the data, and press PAUSE
button.
7
8
4C
96
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Data of page: 3,
address: 03
72
74
75
76
Contents of the abnormality
S VIDEO OUT Y Level adjustment
(IC4701 line on) error
IC4701 panel (LCD) clamp level
adjustment error
IC4001 panel (LCD) output level
adjustment error
IC4701 panel (LCD) output level
adjustment error
Fig. 6-3-8.
H
B
A
6-56
DCR-HC90/HC90E
3-5.
AUDIO SYSTEM ADJUSTMENTS
[Connection of Audio System Measuring Devices]
Connect the audio system measuring devices as shown in Fig. 6-3-9.
Fig. 6-3-9
Recording (PLAY/EDIT mode)
Audio oscillator
Attenuator
600 
Left
Right
Main unit
AUDIO/
VIDEO
IN
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
Main unit
AUDIO/
VIDEO
OUT
Left (White)
Right 
47k 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k 
 (1-249-437-11)
Playback (PLAY/EDIT mode)
(Red)
6-57
DCR-HC90/HC90E
1. Playback Level Check
Mode
VTR playback
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
Audio left or right terminal of AUDIO
VIDEO jack
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, +3.0 
±
 2.0dBs
48 kHz mode: 1 kHz, +3.0 
±
 2.0dBs
44.1 kHz mode:
The 7.35kHz signal level during EMP
OFF is +2.0 
±
 2.0dBs.
The 7.35kHz signal level during EMP
ON is –6 
±
 2 dB from the signal level
during EMP OFF.
Checking Method:
1)
Check that the playback signal level is the specified value.
2. Overall Level Characteristics Check
Mode
VTR recording and playback
Signal
400Hz, –7.5 dBs signal: AUDIO
VIDEO jack left and right
Measurement Point
Audio left or right terminal of AUDIO
VIDEO jack
Measuring Instrument
Audio level meter
Specified Value
–7.5 
±
 3.0dBs
Checking Method:
1)
Input the 400Hz, –7.5dBs signal in the AUDIO VIDEO jack.
2)
Record in the PLAY/EDIT mode.
3)
Playback the recorded section.
4)
Check that the 400Hz signal level is the specified value.
3. Overall Distortion Check
Mode
VTR recording and playback
Signal
400Hz, –7.5dBs signal: AUDIO
VIDEO jack left and right
Measurement Point
Audio left or right terminal of AUDIO
VIDEO jack
Measuring Instrument
Audio distortion meter
Specified Value
Below 0.4%
(200Hz to 6kHz BPF ON)
Checking Method:
1)
Input the 400Hz, –7.5dBs signal in the AUDIO VIDEO jack.
2)
Record in the PLAY/EDIT mode.
3)
Playback the recorded section.
4)
Check that the distortion is the specified value.
4. Overall Noise Level Check
Mode
VTR recording and playback
Signal
No signal: Insert a shorting plug in the
AUDIO VIDEO jack
Measurement Point
Audio left or right terminal of AUDIO
VIDEO jack
Measuring Instrument
Audio level meter
Specified Value
Below –45dBs
(IHF-A filter ON, 20kHz LPF ON)
Checking Method:
1)
Insert a shorting plug in the AUDIO VIDEO jack.
2)
Record in the PLAY/EDIT mode.
3)
Playback the recorded section.
4)
Check that the noise level is the specified value.
5. Overall Separation Check
Mode
VTR recording and playback
Signal
400Hz, –7.5dBs signal: AUDIO
VIDEO jack <right> [left]
(Connect the AUDIO VIDEO jack
<left> [right] to GND)
Measurement Point
Audio <left> [right] terminal of
AUDIO VIDEO jack
Measuring Instrument
Audio level meter
Specified Value
Below –40dBs (IHF-A filter ON)
< > : Left channel check
[   ] : Right channel check
Checking Method:
1)
Input the 400Hz, –7.5dBs signal in the <right> [left] terminal
of the AUDIO VIDEO jack only.
2)
Record in the PLAY/EDIT mode.
3)
Playback the recorded section.
4)
Check that the signal level of the audio <left> [right] terminal
is the specified value.
Page of 70
Display

Click on the first or last page to see other DCR-HC90 / DCR-HC90E (serv.man4) service manuals if exist.