Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc30-dcr-hc30e-sm4.pdf
Date

Sony DCR-HC30 / DCR-HC30E (serv.man4) Service Manual ▷ View online

6-6
DCR-HC30/HC30E
Fig. 6-1-3.
7
5
3
2
6
4
1
3
AC power
adaptor 
AC IN
Adjustment remote
commander (RM-95)
LANC jack
DC-IN connector
For tape path adjustment
CPC lid
Screw (M1.7x4)
black
8
1
1
 RF MON
2
 SWP
3
 GND
4
 XSC EEP
5
 EEP SCK
6
 EEP SO
7
 EEP SI
I/F unit for LANC control
(J-6082-521-A)
CPC-15
(J-6082-564-A)
*1
*1
[CONNECTION OF EQUIPMENT]
CN002
CN001
BATT
LANC
Not used
Not used
Not used.
Not used
*1: Don’t connect any cable 
to these connectors.
6-7
DCR-HC30/HC30E
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
MODE switch (SS6300 block) ................... CAMERA-TAPE
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
BACK LIGHT switch (CF6300 block) ............................ OFF
4.
MENU settings (Touch panel)
CAMERA SET menu
PROGRAM AE .................................................... AUTO
SPOT METER ...................................................... AUTO
EXPOSURE ............................................................. OFF
WHITE BALANCE ............................................. AUTO
FOCUS .......................................................... MANUAL
COLOR SLOW SHUTTER ..................................... OFF
DIGITAL ZOOM ..................................................... OFF
16:9 WIDE ................................................................ OFF
STEADY SHOT ....................................................... OFF
PICT. APPLI menu
DIGITAL EFECT ..................................................... OFF
PICTURE EFECT .................................................... OFF
DEMO MODE ......................................................... OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.6-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
Fig. 6-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
6-8
DCR-HC30/HC30E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1A,
1B, 1C, 1F PAGE DATA
Note:
When reading or writing the 18, 1A, 1B, 1C or 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, A, B, C or F page.
The 18, 1A, 1B, 1C or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
LOADING OF FLASH MEMORY PROGRAM
Read the program for the HI/DS controller (IC8301) from the
Memory Stick Duo, and write it to the flash memory (IC8503) of
the HI/DS controller.
Note:
The data of page: 0, address: 10 must be “00”.
1. Preparation
1)
Write the VERMEER. BIN file (program file for the HI/DS
controller) to a Memory Stick Duo using a personal computer.
Note:
Contact our service headquarter of each area how to get the
VERMEER. BIN file.
2. Loader Writing Permission Mode Setting
Note:
This setting is unnecessary when no program is loaded to the flash
memory, or when “Loader Writing Permission Mode” is set already.
(Refer to “6. Check of Loader Writing Inhibit Mode”.)
Setting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
01
2F
Set the data, and press PAUSE
button.
3
7
02
FF
Set the data, and press PAUSE
button.
4
7
04
00
Set the data, and press PAUSE
button.
5
7
05
01
Set the data, and press PAUSE
button.
6
7
06
FF
Set the data, and press PAUSE
button.
7
7
00
01
Set the data, and press PAUSE
button.
8
7
02
Check that the data is “01”.
3. Loading Method
1)
Remove the power supply of the camcorder.
2)
Inserts the Memory Stick Duo that memorizes the VERMEER.BIN
file to the memory stick slot.
3)
Connect the adjustment remote commander with the HOLD
switch set to the “ADJ” side.
4)
Connect the power supply to the camcorder.
5)
Check that the MS ACCESS LED is turned on for about 60
seconds. (The program is written in the flash memory in this
period.)
6)
Check that the MS ACCESS LED is turned off.
7)
Remove the Memory Stick Duo from the camcorder.
8)
Turn off the power and turn on again.
9)
Check that the camcorder is normal.
If normal, perform “4. Program Version Check” and “5. Loader
Writing Inhibit Mode Setting”.
If the MS ACCESS LED is blinked, repeat from step 1).
4. Program Version  Check
Order Page Address Data
Procedure
1
5
FE
Read the data, and this data is
named D
FE
.
2
5
FF
Read the data, and this data is
named D
FF
.
Note:
D
FE
 and D
FF
 are the program version.
5. Loader Writing Inhibit Mode Setting
Setting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
01
2F
Set the data, and press PAUSE
button.
3
7
02
FF
Set the data, and press PAUSE
button.
4
7
04
00
Set the data, and press PAUSE
button.
5
7
05
01
Set the data, and press PAUSE
button.
6
7
06
20
Set the data, and press PAUSE
button.
7
7
00
01
Set the data, and press PAUSE
button.
8
7
02
Check that the data is “01”.
9
0
01
00
Set the data.
6. Check of Loader Writing Inhibit Mode
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
01
1F
Set the data, and press PAUSE
button.
3
7
02
FF
Set the data, and press PAUSE
button.
4
7
03
00
Set the data, and press PAUSE
button.
5
7
04
00
Set the data, and press PAUSE
button.
6
7
05
01
Set the data, and press PAUSE
button.
7
7
00
01
Set the data, and press PAUSE
button.
8
7
02
Check that the data is “01”.
9
7
03
Check the data.
20: Loader writing inhibit mode
FF: Loader writing permission mode
10
0
01
00
Set the data.
6-9
DCR-HC30/HC30E
1-2-2.
INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA
Note:
When reading or writing the A, B, D page data, select page: 0,
address: 10, and set data: 00.
When reading or writing the 1A or 1B page data, select page: 0,
address: 10, and set data: 01, then select A or B page. The 1A or 1B
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the A, B, D, 1A, 1B Page Data
Note1:
If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 70
Adjusting page
1A
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
04
Set the following data.
20 (DCR-HC30 (NTSC))
21 (DCR-HC30E (PAL))
4
7
01
XX
Set the data. (Note2)
5
7
00
01
Set the data, and press PAUSE
button.
6
7
02
Check that the data changes to
“01”.
7
Perform “Modification of A, B,
D, 1B Page Data”.
Note2:
XX=20: Initializing A page
XX=21: Initializing B page
XX=22: Initializing D page
XX=23: Initializing 1A page
XX=24: Initializing 1B page
XX=25: Initializing A and 1A page
XX=26: Initializing B and 1B page
XX=28: Initializing A, B, D and 1B page
2. Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the A, B, D page data, select page: 0,
address:10, and set data: 00.
3)
When changing the 1A, 1B page data, select page: 0, address:
10 and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, D, 1A, 1B Page
data
Order Page Address Data
Procedure
1
1
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, B, D, 1A, 1B page data”, check that the data of
addresses: 1A to 4F of A page and the data of addresses: 12 to 19 of
D page are same as those of the same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
Page of 63
Display