DOWNLOAD Sony DCR-HC30 / DCR-HC30E (serv.man4) Service Manual ↓ Size: 785.33 KB | Pages: 63 in PDF or view online for FREE

Model
DCR-HC30 DCR-HC30E (serv.man4)
Pages
63
Size
785.33 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc30-dcr-hc30e-sm4.pdf
Date

Sony DCR-HC30 / DCR-HC30E (serv.man4) Service Manual ▷ View online

6-30
DCR-HC30/HC30E
15. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03MA
Type B : ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (CAMERA SET menu) ......................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(SE-141 board SE401)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(SE-141 board SE402)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcorder.
6-31
DCR-HC30/HC30E
1-4.
COLOR ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
As the PANEL OPEN switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4:
NTSC model : DCR-HC30
PAL model
: DCR-HC30E
Switch setting:
LCD panel ........................................................................... Closed
1. EVF Automatic Adjustment (VC-351 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA-TAPE
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
3F, 40 (VCO adj.)
47 (Contrast adj.)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
71
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
3F
Read the data, and this data is
named D
3F
.
7
Convert D
3F
 to decimal notation,
and obtain D
3F
’. (Note3)
8
Calculate D
40
’ using following
equations (Decimal calculation)
[NTSC model]
When D
3F
’   245
D
40
’ = D
3F
’+10
When D
3F
’ > 245
D
40
’ = 255
[PAL model]
When D
3F
’   10
D
40
’ = D
3F
’– 10
When D
3F
’ < 10
D
40
’ = 0
9
Convert D
40
’ to a hexadecimal
number, and obtain D
40
. (Note3)
10
C
40
D
40
Set the data, and press PAUSE
button.
11
C
71
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2:
If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Note3:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Data of page: 3,
address: C6
5E
61
Contents of error
VCO adjustment error
Contrast adjustment error
6-32
DCR-HC30/HC30E
2. White Balance Adjustment (VC-351 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
45, 46
Specified Value
The EVF screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC9301
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
45
A0
Set the data, and press PAUSE
button.
3
C
46
88
Set the data, and press PAUSE
button.
4
C
46
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5
C
45
Change the data so that the EVF
screen is not colored.
6
C
45
Press PAUSE button.
7
C
46
Change the data so that the EVF
screen is not colored.
8
C
46
Press PAUSE button.
9
C
46
If the EVF screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
6-33
DCR-HC30/HC30E
1-5.
LCD SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
NTSC model : DCR-HC30
PAL model
: DCR-HC30E
Switch setting:
LCD panel ............................................................................. Open
1. LCD Automatic Adjustment (PD-213 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA-TAPE
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
50, 51 (VCO adj.)
58 (Contrast adj.)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
70
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
50
Read the data, and this data is
named D
50
.
7
Convert D
50
 to decimal notation,
and obtain D
50
’. (Note3)
8
Calculate D
51
’ using following
equations (Decimal calculation)
[NTSC model]
When D
50
’   245
D
51
’ = D
50
’ + 10
When D
50
’ > 245
D
51
’ = 255
[PAL model]
When D
50
’   10
D
51
’ = D
50
’ – 10
When D
50
’ < 10
D
51
’ = 0
9
Convert D
51
’ to a hexadecimal
number, and obtain D
51
. (Note3)
10
C
51
D
51
Set the data, and press PAUSE
button.
11
C
70
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2:
If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Data of page: 3,
address: C6
58
60
Contents of error
VCO adjustment error
Contrast adjustment error
Note3:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Page of 63
Display