Sony DCR-HC28 (serv.man3) Service Manual ▷ View online

6-51
DCR-HC28_ADJ
4.
Jack Check
Page 7
Address 0C
Note:
 Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Select page: 7, address: 0C.
2) By discriminating the bit value of display data, the state of jack can be discriminated.
5.
Switch Check (1)
Page 2
Address 81
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Select page: 2, address: 81.
2) By discriminating the bit value of display data, the state of switch can be discriminated.
3.
Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justment remote commander for the following items.  Us the table
below to discriminate if the bit value is “1” or “0”.
(Example) If the remote commander display is “8E”, bit value from
bit 7 to bit 4 can be discriminated from the column 
A
,
and those from bit 3 to bit 0 from column 
B
.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
C
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
Bit
Function
When bit value = 1
When bit value = 0
2
A/V OUT jack (SI-051 board CN601)
Used
Not used
Bit
Function
When bit value = 1
When bit value = 0
0
POWER (SS17000 block)
ON
OFF
1
MODE CHANGE (SS17000 block)
ON
OFF
2
DISP/BATT INFO (CF17000 block S004)
ON
OFF
3
EJECT (SS17000 block S001)
ON
OFF
4
CC DOWN (Mechanism chassis)
ON (DOWN)
OFF (UP)
6-52
DCR-HC28_ADJ
6.
Switch Check (2)
Page 7
Address 5C
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Select page: 7, address: 5C.
2) By discriminating the bit value of display data, the state of switch can be discriminated.
7.
Switch Check (3)
Page 2
Address 60 to 67
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Select page: 2, address: 60 to 67.
2) By discriminating the display data, the pressed key can be discriminated.
Address
60
(KEY AD0)
(IC8001
 
J8
 
)
61
(KEY AD1)
(IC8001
 
J9
 
)
62
(KEY AD2)
(IC8001
 
H8
 
)
63
(KEY AD3)
(IC8001
 
G8
 
)
64
(KEY AD4)
(IC8001
 
F8
 
)
65
(KEY AD5)
(IC8001
 
F9
 
)
66
(KEY AD6)
(IC8001
 
F7
 
)
67
(KEY AD7)
(IC8001
 
J6
 
)
00 to 0C
EASY
(CF17000 block)
(S003)
REC
START/STOP
(SS17000 block)
(S004)
0D to 24
25 to 3F
BACK LIGHT
(CF17000 block)
(S002)
40 to 5D
PANEL
REVERSE
(FP-386 flexble)
(S101)
5E to 81
PANEL
CLOSE
(CF17000 block)
(S001)
82 to AA
AB to D7
D8 to FF
PANEL
NORMAL
(FP-386 flexble)
(S101)
PANEL
OPEN
(CF17000 block)
(S001)
No key input
Data
Bit
Function
When bit value = 1
When bit value = 0
3
REC PROOF SW (Mechanism chassis)
SAVE
REC
6-53
DCR-HC28_ADJ
Initializing method:
Order Page Address Data
Procedure
1
7
A4
00
Press PAUSE (Write) button.
2
7
A5
00
Press PAUSE (Write) button.
3
7
A6
00
Press PAUSE (Write) button.
4
7
A7
00
Press PAUSE (Write) button.
5
7
A8
00
Press PAUSE (Write) button.
6
7
A9
00
Press PAUSE (Write) button.
7
7
AA
00
Press PAUSE (Write) button.
8
7
AB
00
Press PAUSE (Write) button.
9
7
AC
00
Press PAUSE (Write) button.
10
7
AD
00
Press PAUSE (Write) button.
11
7
AE
00
Press PAUSE (Write) button.
12
7
AF
00
Press PAUSE (Write) button.
8.
LED, IR Light Check
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Set the unit to camera mode.
2) Select page: 7, address: 07, and set the bit value of bit5 to “1”.
3) Check that all LED are lit, and that the IR light is lit.
4) Select page: 7, address: 07, and set the bit value of bit5 to “0”.
9.
Record of Use Check (1)
Page 7
Address A4 to AF
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (SI-051 board BT601) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: A4 to
AF.
Page 7
Address 07
Bit5
Address
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Power supplying
Hour (H)
time
Hour (M)
Hour (L)
(BCD code)
Minute
Drum rotation
Hour (H)
counted time
Hour (M)
Hour (L)
(BCD code)
Minute
Tape run time
Hour (H)
Hour (M)
Hour (L)
(BCD code)
Minute
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
6-54
DCR-HC28_ADJ
11. Record of Use Check (3)
Page 7
Address C8 to CD
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (SI-051 board BT601) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
10. Record of Use Check (2)
Page 7
Address D0 to D5
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (SI-051 board BT601) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: D0
to D5.
Initializing method:
Order Page Address Data
Procedure
1
7
D0
00
Press PAUSE (Write) button.
2
7
D1
00
Press PAUSE (Write) button.
3
7
D2
00
Press PAUSE (Write) button.
4
7
D3
00
Press PAUSE (Write) button.
5
7
D4
00
Press PAUSE (Write) button.
6
7
D5
00
Press PAUSE (Write) button.
Address
D0
D1
D2
D3
D4
D5
Function
Eject count without
Count (H)
tape
Count (M)
(BCD code)
Count (L)
Eject count with tape
Count (H)
(BCD code)
Count (M)
Count (L)
Remarks
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
Page of 59
Display

Click on the first or last page to see other DCR-HC28 (serv.man3) service manuals if exist.