DOWNLOAD Sony DCR-DVD308 (serv.man3) Service Manual ↓ Size: 1.07 MB | Pages: 56 in PDF or view online for FREE

Model
DCR-DVD308 (serv.man3)
Pages
56
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-dvd308-sm3.pdf
Date

Sony DCR-DVD308 (serv.man3) Service Manual ▷ View online

6-26
DCR-DVD308_ADJ
5.
Touch Panel Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Touch Panel Adj.
2. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Click the [Start] button of the Touch Panel Adjustment.
2) The Automatic Adjustment Program executes the “1. Touch
Panel Adj.1”. The following message is displayed, and then
adjust the LCD screen in accordance with the instructions given
on the screen. After the adjustment, click the [OK] button in
the message window.
3) If the [OK] button is clicked, “2. Release of Data Setting dur-
ing LCD/EVF Adj.” will be executed.
4) Upon successful completion of all item the Touch Panel Ad-
justment, the following message is displayed. Click the [OK]
button.
4.
EVF Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD/EVF Adj.
2. EVF Automatic Adj.
(VCO Adj., Contrast Adj.)
3. White Balance Adj.
4. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Click the [Start] button of the EVF Adjustment.
2) The Automatic Adjustment Program executes the “1. Data
Setting during LCD/EVF Adj.” and “2. EVF Automatic Adj.”.
3) After that, the following screen is displayed during the execu-
tion of “3. White Balance Adj.”. Check that the EVF screen is
not colored. If colored, using the [Up] / [Down] button on the
screen, adjust so that the EVF screen is not colored. After the
adjustment, click the [End] button in the screen.
4) If the [End] button is clicked,“4.Release of Data Setting dur-
ing LCD/EVF Adj.” will be executed.
5) Upon successful completion of all item the EVF Adjustment,
the following message is displayed. Click the [OK] button.
6-27
DCR-DVD308_ADJ
1-8. 
AJUSTES DE SISTEMA DE ÁUDIO
1.
Function of Each Button on Audio System Adjust-
ment Screen
Click the [AUDIO SYSTEM ADJUSTMENT]  button on the Main
Menu screen, and the “AUDIO SYSTEM ADJUSTMENT” screen
in Fig. 6-1-16 will appear.
Fig. 6-1-16
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
“Audio Adjustment” starts.
4
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”.
When the data setting is cancelled, the button color returns to
“white”. (Use this button when an error occurred in the audio
adjustment. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
2.
Adjustment Items of AUDIO System Adjustment
The adjustment items of audio system adjustment are as listed in
Table 6-1-6. The Automatic Adjustment Program executes the ad-
justment items when the AUDIO Adjustment Start button is clicked.
4
3
2
1
Block
Page
Address
AUDIO
Adjustment
Internal 3ch Microphone Sensitivity Adj.
10
60
0104 to 010C
Adjusting Address
Button Name
Adjustment
Table 6-1-6
6-28
DCR-DVD308_ADJ
3.
AUDIO Adjustment
Note 1:
Perform “AUDIO Adjustment” without inserting disc.
Note 2:
AUDIO Adjustment is available only once after the power
is turned on. If the adjustment is retried, turn off the power
and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during AUDIO Adj.
2. Internal 3ch microphone Adj.
3. Release of Data Setting during Audio Adj.
[Preparation]
Prepare an amplifier built-in speaker for PC and arrange it above
the internal 3ch microphone of the camcoder.
• Adjust the speaker position so that it is within ±3 cm from the
center of camcoder internal 3ch microphone at the height of 40
cm.
• The diaphragm of speaker position should be set face down to-
ward the internal 3ch microphone.
• The speaker may be held by hand if it is hard to secure.
Fig. 6-1-17
[Adjusting method]
1) Play back the adjustment sound source file on the PC.
2) Set the speaker volume so that the adjustment signal sound is
heard to the extent of the loudness of talking voices.
3) Click the [Start] button of the AUDIO Adjustment.
4) The Automatic Adjustment Program executes “1. Data Setting
during Audio Adj.”.
5) When “1. Data Setting during Audio Adj.” completed success-
fully, and the items “2. Internal 3ch microphone Adj.” and “3.
Release of Data Setting during Audio Adj.” will be executed.
6) Upon successful completion of all items of the AUDIO Ad-
justment, the following message is displayed. Click the [OK]
button.
In case of adjustment NG, reduce or increase the speaker volume,
and then retry adjustment.
If the Adjustment Program displays a message “Volume too loud”
or “Volume too low”, adjust the speaker volume following the
message.
Amplifier built-in 
speaker for PC
PC
Internal 3ch 
microphone
about 40 cm
6-29
DCR-DVD308_ADJ
1-9. ERRO
In the case of an error during the execution of adjustment, the
Automatic Adjustment Program interrupts the processing at that
point, and displays an error message, and then terminates the pro-
gram execution there.
1-9-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error, Adjust Control Error
Fig. 6-1-18
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SeusEX is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SeusEX and click the [Connect]  to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-19
Symptom
The camera is not ready for adjustment.
Cause
Data error exists in the camera.
Remedy
Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-20
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-21
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
Page of 56
Display

Click on the first or last page to see other DCR-DVD308 (serv.man3) service manuals if exist.