DOWNLOAD Sony DCR-DVD308 (serv.man3) Service Manual ↓ Size: 1.07 MB | Pages: 56 in PDF or view online for FREE

Model
DCR-DVD308 (serv.man3)
Pages
56
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-dvd308-sm3.pdf
Date

Sony DCR-DVD308 (serv.man3) Service Manual ▷ View online

6-14
DCR-DVD308_ADJ
4) After that, the following screen is displayed during the execu-
tion of “3. S VIDEO OUT Chroma Level Adj.”. Using the [Up]/
[Down] button on the screen, adjust so that the Cr signal level
and the Cb signal level satisfies the specified value. After the
adjustment, check that the burst level of the chroma signals
satisfies the specified value, and click the [End] button in the
screen.
5) If the [End] button is clicked, “4. VIDEO OUT Level Check”
will be executed. The following message and screen are dis-
played. Check that the sync signal level and burst level of the
video signals satisfies the specified value, and click the [OK]
button in the message.
6) If the [OK] button is clicked, “5. Release of Data Setting dur-
ing Video Adj.” will be executed.
7) Upon successful completion of all item the VIDEO Adjust-
ment, the following message is displayed. Click the [OK] but-
ton.
6-15
DCR-DVD308_ADJ
1-6. 
AJUSTE DE SISTEMA DA CÂMERA
1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-11 will appear.
Fig. 6-1-11
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 5” starts.
4
Model Select radio button
Selects the model to be adjusted.
Note:
NTSC model: DCR-DVD308/DVD708
PAL model: DCR-DVD306E/DVD308E/DVD708E
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
5
4
3
2
1
2
3
3
6-16
DCR-DVD308_ADJ
2.
Adjustment Items of Camera System Adjustment
The adjustment items of camera system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program divides the ad-
justment items into five, camera adjustment 1-5. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note:
 Dark Siemens star chart.
Table 6-1-4
Block
Page
Address
CAMERA
Adjustment 1
HALL Adj.
Not required
11
61
0250 to 0258
Siemens star chart with ND filter for
minipattern box (Note) or
Flange back adjustment jig
Flange back adjustment chart and
subject more than 500 m away
CAMERA
Adjustment 3
Flange Back Check
Siemens star chart
-
-
-
F No. Standard Data Input
11
61
0260 to 026F
MAX GAIN Adj.
11
61
025E
Mechanical Shutter Adj.
11
61
0220 to 0235
Color Reproduction Adj.
11
61
0061, 0063,
0067, 0068
Color Reproduction Check
-
-
-
AWB Standard Data Input
11
61
0074 to 007B
LV Standard Data Input
11
61
025C, 025D
AWB Adj.
Clear chart
(All White frame)
Filter C14 for color temperature
correction
11
61
0070 to 0073,
008C to 0093
AWB Check
Clear chart
(All White frame)
ND filter 1.0, 0.4 and 0.1
-
-
-
CAMERA
Adjustment 5
Steady Shot Check
Not required
-
-
-
0020 to 0030,
004C, 004D
CAMERA
Adjustment 4
Clear chart
(All White frame)
61
11
CAMERA
Adjustment 2
Flange Back Adj.
Color bar chart
(Color reproduction adjustment frame)
Clear chart
(Center frame)
Subject
Adjustment
Button Name
Adjusting Address
6-17
DCR-DVD308_ADJ
3.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. HALL Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items “2. HALL Adj.” and “3. Release of Data
Setting during Camera Adj.” will be executed.
4) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
Page of 56
Display

Click on the first or last page to see other DCR-DVD308 (serv.man3) service manuals if exist.