DOWNLOAD Sony CCD-TRV63 / CCD-TRV66 / CCD-TRV66PK Service Manual ↓ Size: 30.13 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV63 CCD-TRV66 CCD-TRV66PK
Pages
127
Size
30.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv63-ccd-trv66-ccd-trv66pk.pdf
Date

Sony CCD-TRV63 / CCD-TRV66 / CCD-TRV66PK Service Manual ▷ View online

5-29
5-2. MECHANISM SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video
Mechanism Adjustment Manual 
   B Mechanism  ”.
2-1. OPERATING WITHOUT CASSETTE
1)
Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without loading a cassette and
complete loading.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: F, address: 2C, set data: 01, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette.
Be sure to carry out “Processing after Operations” after
checking the operations.
Set the data of page: D, address: 10 to the following if the
sensor ineffective mode, forced VTR power supply On mode
or forced camera power supply ON mode are to be used
together.
Forced VTR power ON mode ........................................ 12
Forced camera power ON mode .................................... 11
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-2. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape path face (tape guide, capstan shaft, pinch roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: F, address: 2C, set data: 04, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after
completing adjustments.)
6)
Connect the oscilloscope to VC-214 board CN910 via CPC-7
jig (J-6082-382-A).
Channel 1: VC-214 board, CN910 Pin 6
External trigger: VC-214 board, CN910 Pin !¡
7)
Playback an alignment tape for tracking. (WR5-1NP)
8)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, adjust according to the separate volume “8mm Video
Mechanical Adjustment Manual 
   B Mechanism  ”.
9)
Perform “Processing after operations”, after completing
adjustment.
CN910 of VC-214 board
Table 5-2-1.
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Remove the power supply from the unit.
Fig. 5-2-1.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
LANC SIG
XCPC IN
IR VIDEO
AFC F0
BPF MONI
PB RF
RF AGC IN
REG GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
RF AGC OUT
REC RF
RF SWP
CAP FG
EVF BL
EVF BL 4.75V
VCO
EVF VG
Must be flat 
5-30
5-3. VIDEO SECTION ADJUSTMENTS
3-1. PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1. Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• For tracking adjustment (WR5-1NP)
Parts code : 8-967-995-02
• For video frequency characteristics adjustment (WR5-7NE)
Parts code : 8-967-995-13
• For checking Standard 8 mode operations
• For LP (WR5-4NL)
Parts code : 8-967-995-51
• For SP (WR5-5NSP)
Parts code : 8-967-995-42
Note:
The following alignment tapes can also be used.
WR5-4NSP (8-967-995-41)
• For checking Hi8 mode operations
• For LP (WR5-8NLE)
Parts code : 8-967-995-52
• For SP (WR5-8NSE)
Parts code : 8-967-995-43
• For Checking AFM stereo operations (WR5-9NS)
Parts code : 8-967-995-23
• For BPF adjustment (WR5-11NS)
Parts code : 8-967-995-71
12) Adjustment remote commander (J-6082-053-B)
13) CPC-7 jig (J-6082-382-A)
14) Power code (J-6082-223-A)
Note:
Connect the adjustment remote commander to the LANC jack,
and set the HOLD switch to the “ADJ” side.
15) AFM DEV jig (J-6082-312-A)
16) IR receiver jig (J-6082-383-A)
17) Extension cable (70P, 0.5mm)
For extension between the DD-117 board (CN931) and the VC-
214 board (CN914) (J-6082-439-A)
5-31
3-1-2. Precautions on Adjusting
1)
The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “VTR” or set
the “Forced VTR Power ON mode” using the adjustment remote
commander (Note 1).
To set to the Camera mode, set the power switch to “CAMERA”
or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”. (Note 3)
2)
By setting the “Forced VTR Power ON mode” or “Forced
Camera Power ON mode”, the video section can be operate
even if even if the front panel block (MA-351 board, power
switch, microphone unit) has been removed. When removing
the front panel block disconnect the following connector.
1. VC-214 board CN903 (20P 0.5mm)
3)
The lens block (CD-209 board) and VL-23 board need not be
connected except during battery end adjustment. To remove,
disconnect the following connectors.
1. VC-214 board CN501 (16P, 0.5mm)
2. VC-214 board CN551 (24P, 0.5mm)
3. VL-23 board CN151 (8P, 0.5mm)
4)
Cabinet (R) (Camera function switch (CF-56 board), LCD
block, viewfinder) need not be connected. But removing the
cabinet (R) (removing the VC-214 board CN911) means
removing the lithium 3V power supply (CF-56 board) , data
such as date, time, user-set menus will be lost. After completing
adjustments, reset these data. If the cabinet (R) has been
removed, the self-diagnosis data, data on history of use (total
drum rotation time etc. ) will be lost. Before removing, note
down the self-diagnosis data and data on history use (data of
page: 2, address: A2 to AA). (Refer to the “Service Mode” for
the data on the history use.) To remove the cabinet (R),
disconnect the following connectors.
1. VC-214 board CN911 (50P, 0.5mm)
2. DD-117 board CN933 (10P, 1.0mm)
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the “Forced VTR
Power ON mode”.
Note 2:
Setting the “Forced Camera Power ON” mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the “Forced
Camera Power ON mode”.
Note 3:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
3-1-3. Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-214 board CN910. Connect the measuring instruments via
the CPC-7 jig (J-6082-382-A). The following table lists the pin
numbers and signal names of CN910.
Table 5-3-1.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
LANC SIG
XCPC IN
IR VIDEO
AFC F0
BPF MONI
PB RF
RF AGC IN
REG GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
RF AGC OUT
REC RF
RF SWP
CAP FG
EVF BL
EVF BL 4.75V
VCO
EVF VG
Fig. 5-3-1.
CN910
1
16
Screw driver (–)
Cover
5-32
Connecting the TV Monitor and Regulated Power Supply
Battery terminal
Regulated power supply
8.4  0.1Vdc
+
_
Main Unit
VIDEO terminal
VIDEO
Connect when using the camera
mode or playing back.
TV monitor
3-1-4. Connecting the Equipments
Connecting the measuring instruments as shown in Fig. 5-3-2 and
perform the adjustments.
Fig. 5-3-2.
Page of 127
Display

Click on the first or last page to see other CCD-TRV63 / CCD-TRV66 / CCD-TRV66PK service manuals if exist.