DOWNLOAD Sony CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 Service Manual ↓ Size: 22.49 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV15 CCD-TRV15E CCD-TRV15EP CCD-TRV15PK CCD-TRV215 CCD-TRV25 CCD-TRV25PK CCD-TRV35 CCD-TRV35E CCD-TRV615 CCD-TRV65 CCD-TRV65PK CCD-TRV815 CCD-TRV85 CCD-TRV93
Pages
127
Size
22.49 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M CCD-TRV15/25/35/65''98 US E
File
ccd-trv15-ccd-trv15e-ccd-trv15ep-ccd-trv15pk-ccd-t.pdf
Date

Sony CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 Service Manual ▷ View online

5-6
1-1-4. Adjusting Remote Commander
The adjusting remote commander is used for changing the
calculation coefficient in signal processing, EVR data, etc. The
adjusting remote commander performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communication
is written in the non-volatile memory.
1. Using the adjusting remote commander
1) Connect the adjusting remote commander to the LANC terminal.
2) Adjust the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
If it has been properly connected, the LCD on the adjusting remote
commander will display as shown in Fig. 5-1-7.
Fig. 5-1-7.
3) Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH– button is
pressed. There are altogether 16 pages, from 0 to F.
Table 5-1-1.
• Changing the address
The address increases when the FF (
)) button is pressed,
and decreases when the REW (
0) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (
() button is pressed,
and decreases when the STOP (
p) button is pressed.
There are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (D, E, F page) in the nonvolatile memory.
(The new adjustment data will not be recorded in the nonvolatile
memory if this step is not performed.)
4) Select page: 0, address: 01, and set the data to 01, and enables
Page D and E, F to be adjusted.
5) After completing all adjustments, set data: 00 to page: 0, address:
01 and turn off the main power supply (8.4V) once.
2. Precautions upon using the adjusting remote
commander
Mishandling of the adjusting remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments
and new adjustment data after each adjustment.
Page
Data
Address
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
5-7
Hexadecimal notation-Decimal notation
Note:
(
) indicate the adjusting remote commander display.
(Example)
In the case that the DDS display and the adjusting remote commander display are BD (
bd).
As the upper digit of the hexadecimal notation is B (
b), and the lower digit is D (d), the intersection “189" of the 1
and 
2 in the above table is the decimal notation to be calculated.
The lower digits of the
hexadecimal notation
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
(
A
)
(
b
)
(
c
)
(
d
)
(
E
)
(
F
)
The upper digits of the
hexadecimal notation
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
n
1n
1-1-5. Data Processing
The calculation of the DDS display and the adjusting remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this case,
after converting the hexadecimal notation to decimal notation,
calculate and convert the result to hexadecimal notation, and use it
as the adjustment data. Table 5-1-2. indicates the hexadecimal
notation-the decimal notation calculation table.
Table 5-1-2.
2
5-8
1-2. INITIALIZATION OF D, E, F PAGE DATA
1. Initializing the D,E,F Page Data
Note 1: If “Initializing the D, E, F Page Data” is performed,
all data of the D page, E page and F page will be
initialized. (It is impossible to initialize a single
page.)
Note 2:
If the D,E,F page data has been initialized, “Modification
of D, E, F Page Data” and all adjustments need to be
performed again.
Note 3:
<  > : NTSC  model  (CCD-TRV15/TRV15PK/TRV25/
TRV25PK/TRV35/TRV65/TRV65PK/
T RV 8 5 / T RV 9 3 / T RV 2 1 5 / T RV 8 1 5 /
TRV815)
[   ] : PAL model (CCD-TRV15E/TRV15EP/TRV35E)
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 00, and set data: 55 <NTSC> or
data : 51 [PAL].
3) Select page: 2, address: 01, set data: 55<NTSC> or data : 51
[PAL], and press the PAUSE button of the adjusting remote
commander.
4) Select page: 2, address: 02, and check that the data is 01.
5) Select page: 3, address: 00, and set data: 29.
6) Select page: 3, address: 01, set data: 29, and press the PAUSE
button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
8) Perform “Modification of D,E,F Page Data”.
Adjusting page
D
Adjusting Address
00 to 6F
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
2. Modification of D, E, F Page Data
If the D, E, F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because they
are different in destination. When changing the data, copy the
data built in the same model.
Note :
If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the adjusting
remote commander each time when setting new data to write the
data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the inital value.
5) After compleating “Modification of D, E, F Paga Data”  select
page: 0, address: 01, and set data: 00. Also perform all
adjustments.
5-9
Address
Initial Value
Remark
NTSC PAL
00 to 0F
10
00
00
Fixed data-1
11
00
00
(Initialized data)
12
00
00
13
Fixed data-2
14
(Modified data, copy the data
15
built in the same model.)
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
Fixed data-1
2B
(Initialized data)
2C
2D
2E
Fixed data-2
2F
30
88
88
Battery end adj.
31
8D
8D
32
A8
A8
33
BD
BD
34
C8
C8
35
Fixed data-2
36
(Modified data, copy the data
37
built in the same model.)
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
Address
Initial Value
Remark
NTSC PAL
4B
Fixed data-1
4C
(Initialized data)
4D
4E
4F
50
Fixed data-2
51
(Modified data, copy the data
52
built in the same model.)
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
Fixed data-1
61
(Initialized data)
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
3. D Page Table
Note1 :
Fixed data-1 : Initialized data.
(Refer to “1. Initializing the D,E,F Page Data”.)
Fixed data-2 : Modified data.
(Refer to “2. Modification of D, E, F Page Data”).
Page of 127
Display

Click on the first or last page to see other CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 service manuals if exist.