DOWNLOAD Sony CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 Service Manual ↓ Size: 22.49 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV15 CCD-TRV15E CCD-TRV15EP CCD-TRV15PK CCD-TRV215 CCD-TRV25 CCD-TRV25PK CCD-TRV35 CCD-TRV35E CCD-TRV615 CCD-TRV65 CCD-TRV65PK CCD-TRV815 CCD-TRV85 CCD-TRV93
Pages
127
Size
22.49 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M CCD-TRV15/25/35/65''98 US E
File
ccd-trv15-ccd-trv15e-ccd-trv15ep-ccd-trv15pk-ccd-t.pdf
Date

Sony CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 Service Manual ▷ View online

5-18
6. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Specified Value
All color luminance points should settle within each color
reproduction frame.
Note1:
NTSC 510H model (CCD-TRV15/ TRV15PK)
NTSC 760H model (CCD-TRV25/ TRV25PK/ TRV35/
TRV65/ TRV65PK/ TRV85/ TRV93/ TRV215/
TRV615/ TRV815)
PAL 510H model (CCD-TRV15E/ TRV15EP)
PAL 760H model (CCD-TRV35E)
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, set data: 3D, and press the PAUSE
button of the adjusting remote commander.
3) Select page: F, address: 25, set data: 3F, and press the PAUSE
button of the adjusting remote commander.
4) Adjust the GAIN and PHASE of the vectorscope, and adjust the
burst luminance point to the burst position of the color
reproduction frame.
5) Change the data of page: F, address: 34, 36, F5 and F6, and
settle each color luminance point in each color reproduction
frame.
Note 2:
Be sure to press the PAUSE button of the adjusting remote
commander before changing the of addresses. If not, the
new data will not be written to the memory.
6) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
Subject
Color bar chart standard picture frame
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
34, 36, F5, F6
Fig. 5-1-10.
Burst positon
For NTSC 510H model
Burst positon
For NTSC 760H model
Burst positon
For PAL 510H/PAL 760H model
5-19
7. IRIS IN/OUT Adjustment
For the unit to judge if the white balance is indoors or outdoors in
auto white balance operations, measure the light level and write it
in the EEPROM.
If the level is not correct, the white balance will not be accurate.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
3C, 3D
Note 1:
The right four digits of the display data at the right bottom side
of the LCD and TV monitor is the LIGHT LEVEL data.
   00 XX XX
n Lower two digits
n Upper two digits
Switch setting:
1) STEADY SHOT (Menu display) .................................... OFF
2) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 06.
3) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 01, set data: 0B, and press the PAUSE
button of the adjusting remote commander.
6) Read the DDS display data (Note 1), and take the upper two
digits as D
1
 and the lower two as D
2
.
7) Convert D
1
 to decimal notation, and obtain D
1
'. (Refer to Table
5-1-2. “Hexadecimal notation - decimal notation conversion
table” of “Service mode”.)
8) Calculate D
3
' using the following equations.  (Equations 1 and
2 are for decimal notation calculation).
When  D
2
    D0
D
3
' = D
1
' - 21 ................................................... Equation 1
When  D
2
 < D0
D
3
' = D
1
' - 22 ................................................... Equation 2
9) Convert D
3
' to hexadecimal notation, and obtain D
3
.
10) Select page: F, address: 3C, set data: D
3
, and press the PAUSE
button of the adjusting remote commander.
11) Select page: 2, address: 01, set data: 09, and press the PAUSE
button of the adjusting remote commander.
12) Read the DDS display data (Note 1), and take the upper two
digits as D
4
 and the lower two as D
5
.
13) Convert D
4
 to decimal notation, and obtain D
4
'. (Refer to Table
5-1-2. “Hexadecimal notation - decimal notation conversion
table” of “Service mode”.)
14) Calculate D
6
' using the following equations.  (Equations 3 and
4 are for decimal notation calculation).
When  D
5
    F0
D
6
' = D
4
' - 13 ................................................... Equation 3
When  D
5
 < F0
D
6
' = D
4
' - 14 ................................................... Equation 4
15) Convert D
6
' to hexadecimal notation, and obtain D
6
.
16) Select page: F, address: 3D, set data: D
6
, and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 00.
5) Select page: 0, address: 03, and set data: 00.
8. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Note 1:
The right two digits of the display data at the right bottom
side of the LCD and TV monitor is the object data.
00 00 XX
n Object data
Note 2:
NTSC 510H model (CCD-TRV15/TRV15PK)
NTSC760H model (CCD-TRV25/TRV25PK/TRV35/
T RV 6 5 / T RV 6 5 P K / T RV 8 5 / T RV 9 3 /
TRV215/TRV615/TRV815)
PAL 510H model (CCD-TRV15E/15EP)
PAL 760H model (CCD-TRV35E)
Switch setting:
1) STEADY SHOT (Menu display) ...................................... OFF
2) NIGHT SHOT switch ....................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 02, and press the PAUSE
button of the adjusting remote commander.
3) Select of page: 0, address: 03, and set data: 01.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 56, and set data: 40.
6) Select page: 2, address: 01, set data: 19, and press the PAUSE
button of the adjusting remote commander.
7) Select page: F, address: 31, set data: [18] <08>, and press the
PAUSE button of the adjusting remote commander.
Note : [   ] : 510H model
<  > : 760H model
8) Check that the DDS display data (Note 1) lies within the specified
value.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 00.
5) Select page: 2, address: 56, and set data: 00.
6) Select page: 0, address: 03, and set data: 00.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
31
Specified Value
C0 to FF
5-20
9. Auto White Balance Standard Data Input
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 2, address: 02 is 00. If not,
turn the power of the unit OFF/ON.
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Wait for 2 seconds.
3) Select page: 2, address: 01, and set data: 11, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 0D, and press the PAUSE
button of the adjusting remote commander.
(When the standard data is take in, the data will be automatically
input to page: F, address: 70 to 73.)
5) Select page: 2, address: 02, and check that the data is “01”.
6) Perform “Auto White Balance Adjustment”.
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
70 to 73
10. White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
3A, 3B
Specified Value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
Perform “Auto White Balance Standard Data Input” before
this adjustment.
Note 2:
The right four digits of the display data at the right bottom
side of the LCD and TV monitor is the object data.
00 XXXX
n Object data
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Place the C14 filter for color temperature correction on the lens.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 3F, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 0, address: 03, and set data: 04.
6) Select page: F, address: 3A, and change the data, and adjust the
average value of the DDS display data(Note 2) to the R ratio
specified value.
7) Press the PAUSE button of the adjusting remote commander.
8) Select page: 0, address: 03, and set data: 05.
9) Select page: F, address: 3B, and change the data, and adjust the
average value of the DDS display data(Note 2) to the B ratio
specified value.
10) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 0, address: 03, and set data: 00.
5-21
11. White Balance Check
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Checking method:
1) Check that the lens is not covered with either filter.
2) Select page: 2, address: 01, set data: 0F, and press the PAUSE
button of the adjusting remote commander.
3) Check that the center of the white luminance point is within the
circle shown Fig. 5-1-11.A.
4) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 2, address: 01, set data: 23, and press the PAUSE
button of the adjusting remote commander.
6) Place the C14 filter on the lens.
7) Check that the center of the white luminance point settles in the
circle shown Fig. 5-1-11.B.
8) Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3) on
the lens.
9) Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
10) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-11.C.
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-11. A to C
Fig.5-1-11. A
Fig.5-1-11. B
Fig.5-1-11. C
B-Y
2 mm
2 mm
R-Y
1.0 mm
1.0 mm
B-Y
R-Y
3 mm
3 mm
R-Y
B-Y
2.0 mm
3 mm
1.0 mm
3 mm
Page of 127
Display

Click on the first or last page to see other CCD-TRV15 / CCD-TRV15E / CCD-TRV15EP / CCD-TRV15PK / CCD-TRV215 / CCD-TRV25 / CCD-TRV25PK / CCD-TRV35 / CCD-TRV35E / CCD-TRV615 / CCD-TRV65 / CCD-TRV65PK / CCD-TRV815 / CCD-TRV85 / CCD-TRV93 service manuals if exist.