DOWNLOAD Sony CCD-TRV118 / CCD-TRV218E / CCD-TRV318 / CCD-TRV418 / CCD-TRV418E (serv.man2) Service Manual ↓ Size: 766.93 KB | Pages: 53 in PDF or view online for FREE

Model
CCD-TRV118 CCD-TRV218E CCD-TRV318 CCD-TRV418 CCD-TRV418E (serv.man2)
Pages
53
Size
766.93 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
ccd-trv118-ccd-trv218e-ccd-trv318-ccd-trv418-ccd-t.pdf
Date

Sony CCD-TRV118 / CCD-TRV218E / CCD-TRV318 / CCD-TRV418 / CCD-TRV418E (serv.man2) Service Manual ▷ View online

CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-27
COVER
COVER
6-2. MECHANISM SECTION ADJUSTMENTS
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video Mecha-
nism Adjustment Manual IX
M2000 Mechanism
”.
2-1.
ADJUSTMENT REMOTE COMMANDER
Connect the adjustment remote commander to CN712 of VC-303
board via I/F unit for LANC control (J-6082-521-A) and CPC jig
connector (J-6082-539-A). To operate the adjustment remote com-
mander, connect the AC power adapter (8.4Vdc) to the DC IN
jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
2-2.
OPERATING WITHOUT CASSETTE
1) Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2) Connect the adjustment remote commander.
3) Turn  on the HOLD switch of the adjustment remote com-
mander.
4) Close the cassette compartment without loading a cassette and
complete loading.
5) Select page: 0, address: 01, and set data: 01.
6) Select page: F, address: 20, set data: 01, and press the PAUSE
button of the adjustment remote commander.
7) Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8) Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette.
Be sure to carry out “Processing after Operations” after check-
ing the operations.
Set the data of page: D, address: 10 to the following if the
sensor ineffective mode, forced VTR power supply On mode
or forced camera power supply ON mode are to be used to-
gether.
Forced VTR power ON mode ....................................... 12
Forced camera power ON mode ................................... 11
[Procedure after checking operations]
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
5) Disconnect the power supply of the unit.
2-3.
TAPE PATH ADJUSTMENT
1.
Preparations for Adjustment
1) Clean the tape path face (tape guide, capstan shaft, pinch roller).
2) Connect the adjustment remote commander.
3) Turn  on the HOLD switch of the adjustment remote com-
mander.
4) Select page: 0, address: 01, and set data: 01.
5) Select page: F, address: 20, set data: 08, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after com-
pleting adjustments.)
6) Connect the oscilloscope to I/F unit for LANC control.
Channel 1: PB RF (Pin 9 of CN712)
Channel 2 (Trigger): SWP (Pin 5 of CN712)
7) Playback the alignment tape for tracking. (WR5-1NP (NTSC),
WR5-1CP (PAL))
8) Check that the oscilloscope RF waveform is normal at the en-
trance and exit.
If not normal, adjust according to the separate volume “8mm
Video Mechanical Adjustment Manual IX
M2000 Mechanism
”.
9) Perform “Processing after operations”, after completing ad-
justment.
Test point of I/F unit for LANC control
Pin No.
Signal Name
Pin No.
Signal Name
BL
15
EVF VCO
14
EVF VG
BL 4.75
9
PB RF (MON)
3
BPF MONI
6, 8 ,10
GND
TMS
7
REC RF (RF IN)
TDI
TDO
5
SWP
TCK
4
CAP FG
2
IR VIDEO
Note:
 Pin No. are those of CN712.
Table 6-2-1.
[Procedure after operations]
1) Connect the adjustment remote commander, and turn on the
HOLD switch.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
5) Remove the power supply from the unit.
Fig. 6-2-1.
CH1
Entrance 
side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
V
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-28
COVER
COVER
6-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section adjust-
ments.
Note:
NTSC model: CCD-TRV118/TRV318/TRV418
PAL model: CCD-TRV218E/TRV418E
3-1-1. Equipment to Required
1) TV monitor
2) Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe)
3) Frequency counter
4) Digital voltmeter
5) Audio level meter
6) Audio distortion meter
7) Regulated power supply
8) NTSC alignment tapes
• For tracking adjustment (WR5-1NP)
Parts code: 8-967-995-02
• For video frequency characteristics adjustment (WR5-7NE)
Parts code: 8-967-995-13
• For checking Standard 8 mode operations
For LP (WR5-4NL)
Parts code: 8-967-995-51
For SP (WR5-5NSP)
Parts code: 8-967-995-42
Note:
The following alignment tapes can also be used.
WR5-4NSP (8-967-995-41)
• For checking Hi8 mode operations
For LP (WR5-8NLE)
Parts code: 8-967-995-52
For SP (WR5-8NSE)
Parts code: 8-967-995-43
• For BPF adjustment (WR5-11NS)
Parts code: 8-967-995-71
9) PAL alignment tapes
• For tracking adjustment (WR5-1CP)
Parts code: 8-967-995-07
• For video frequency characteristics adjustment (WR5-7CE)
Parts code: 8-967-995-18
• For checking Standard 8 mode operations
For LP (WR5-4CL)
Parts code: 8-967-995-56
For SP (WR5-5CSP)
Parts code: 8-967-995-47
Note:
The following alignment tapes can also be used.
1) WR5-3CL (8-967-995-36)
2) WR5-4CSP (8-967-995-46)
• For checking Hi8 mode operations
For LP (WR5-8CLE)
Parts code: 8-967-995-57
For SP (WR5-8CSE)
Parts code: 8-967-995-48
• For BPF adjustment (WR5-11CS)
Parts code: 8-967-995-76
10) Adjustment remote commander (J-6082-053-B)
11) CPC jig connector (J-6082-539-A)
12) I/F unit for LANC control (J-6082-521-A)
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-29
3-1-2.
Precautions on Adjusting
1) Connect the adjustment remote commander to CN712 of VC-
303 board via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). To operate the adjustment
remote commander, connect the AC power adapter to the DC
IN jack of I/F unit for LANC control, or connect the L series
Info-LITHIUM battery to the battery terminal of I/F unit for
LANC control.
2) The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “PLAYER”
or set the “Forced VTR Power ON mode” using the adjust-
ment remote commander (Note 1).
To  set to the camera mode, set the power switch to “CAM-
ERA” or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”. (Note
3).
3) The front panel block (SI-035 board, microphone unit, video
light) need not be connected. To remove, disconnect the fol-
lowing connector.
VC-303 board CN703 (22P, 0.5 mm)
4) As removing the cabinet (R) assembly (removing CN713 of
the VC-303 board) means removing the lithium 3 V power
supply (CF-3000 block BT001), data such as date, time, user-
set menus will be lost. After completing adjustments, reset these
data. If the cabinet (R) assembly has been removed, the self-
diagnosis data, data on history of use (total drum rotation time
etc.) will be lost. Before removing, note down the self-diagno-
sis data (data of page: 2, address: B0 to C6) and the data on
history use (data of page: 2, address: A2 to AA and E0 to E2).
(Refer to “6-4.Service Mode”.)
5) The cabinet (R) assembly (CF-3000 block, FK-3000 block,
PD-180 board, LCD block) need not be connected to operate
the VTR block. (Note 4) When removing the cabinet (R) as-
sembly, disconnect the following connectors.
1. VC-303 board CN713 (18P, 0.5 mm)
2. VC-303 board CN701 (20P, 0.8 mm)
6) The lens block (CD-409 board) need not be connected. To re-
move, disconnect the following connectors.
1. VC-303 board CN271 (14P, 0.5 mm)
2. VC-303 board CN301 (24P, 0.5 mm)
7) The EVF block need not be connected. To remove, disconnect
the following connectors.
VC-303 board CN705 (20P, 0.5 mm)
8) By setting the “Forced VTR Power ON mode” or “Forced Cam-
era Power ON mode”, the video section can be operate even if
the control switch block (SS-3000) has been removed. When
removing the control switch block (SS-3000), disconnect the
following connector.
VC-303 board CN711 (12P, 0.8 mm)
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press
the PAUSE button.
The above procedure will enable the VTR power to be
turned on with the control switch block (SS-3000) re-
moved.
After completing adjustments, be sure to exit the “Forced
VTR Power ON mode”.
Note 2:
Setting the “Forced Camera Power ON” mode (Camera
mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button.
The above procedure will enable the camera power to be
turned on with the control switch block (SS-3000) re-
moved.
After completing adjustments, be sure to exit the “Forced
Camera Power ON mode”.
Note 3:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button.
3) Select page: 0, address: 01, and set data: 00.
Note 4:
When the FK-3000 block or the CF-3000 block is re-
moved, the VTR does an unusual movement for one af-
ter the power is turned on.
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-30
CN712
16
1
Conductor 
side
3-1-3. Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-303 board CN712. Connect the measuring instruments via
I/F unit for LANC control (J-6082-521-A) and CPC jig connector
(J-6082-539-A).
The following table shows the pin No. and signal name of CN712.
Pin No.
Signal Name
Pin No.
Signal Name
1
N. C.
9
PB RF
2
PB RF
10
REG GND
3
BPF MONI
11
LANC OUT
4
CAP FG
12
LANC IN
5
RF SWP
13
XLANC POWER ON
6
REG GND
14
EVF VG
7
REC RF
15
VCO
8
REG GND
16
N. C.
Table 6-3-1
The following table lists the test point of I/F unit of for LANC
control.
Pin No.
Signal Name
Pin No.
Signal Name
BL
15
EVF VCO
14
EVF VG
BL 4.75
9
PB RF (MON)
3
BPF MONI
6, 8, 10
GND
TMS
7
REC RF (RF IN)
TDI
TDO
5
SWP
TCK
4
CAP FG
2
IR VIDEO
Note:
 Pin No. are those of CN712.
Table 6-3-2
3-1-4. Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-2 and
perform the adjustments.
Fig. 6-3-1
Connecting the TV Monitor and Adjustment Remote Commander
Fig. 6-3-2
Note:
Use either the AC power adaptor or the InfoLITHIUM battery as the power supply of I/F unit for LANC control.
L series
Info LITHIUM
battery
(7.2 Vdc)
Video
(yellow)
Color monitor Vector scope
Terminated
75 
Audio (black)
I/F unit for LANC control
(J-6082-521-A)
CPC jig connector
(J-6082-539-A)
Adjustment
remote commander
AC power adaptor
LANC
jack
A/V OUT jack
MAIN UNIT
VC-303 BOARD
CN712
Page of 53
Display