Movie / SECTION 6 ADJUSTMENTS
File
ccd-trv118-ccd-trv218e-ccd-trv318-ccd-trv418-ccd-t.pdf
Date

Sony CCD-TRV118 / CCD-TRV218E / CCD-TRV318 / CCD-TRV418 / CCD-TRV418E (serv.man2) Service Manual ▷ View online

CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-19
8. AWB & LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
34 to 39
Specified Value
0FF0 to 1010
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“AWB & LV Standard Data Input” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting)
(CCD-TRV318/TRV418/TRV418E only) ....................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
82
01
3
Wait for 2 second.
4
6
01
11
Press PAUSE button.
5
6
01
0D
Press PAUSE button. (Note 5)
6
6
02
Check the data changes to
“01”.
7
0
03
06
8
1
Check that the displayed data
(Note 4) satisfied specified
value.
Note 5:
The adjustment data will be automatically input to page:
F, address: 34 to 39.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
82
00
3
0
03
00
4
0
01
00
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-20
9. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
3A, 3B, 90 to 93
Specified value
NTSC model
R ratio: 2BA0 to 2CA0
B ratio: 5790 to 5890
PAL model
R ratio: 2AD0 to 2BD0
B ratio: 58A0 to 59A0
Note 1:
Perform “AWB & LV Standard Data Input” before this
adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If
not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting)
(CCD-TRV318/TRV418/TRV418E only) ....................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
6
82
01
4
F
90
2C/2B Press PAUSE button. (Note 5)
5
F
91
20/50 Press PAUSE button. (Note 5)
6
F
92
58/59 Press PAUSE button. (Note 5)
7
F
93
10/20 Press PAUSE button. (Note 5)
8
6
01
A7
Press PAUSE button.
9
6
01
A5
Press PAUSE button. (Note 6)
10
6
02
Check the data changes to
“01”.
11
6
01
3F
Press PAUSE button.
12
0
03
04
13
1
Check that the displayed data
(Note 4) satisfied the R ratio
specified value.
14
0
03
05
15
1
Check that the displayed data
(Note 4) satisfied the B ratio
specified value.
Note 5:
NTSC model / PAL model
Note 6:
The adjustment data will be automatically input to page:
F, address: 3A and 3B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
82
00
3
0
03
00
4
0
01
00
5
Remove the C14 filter on the
lens.
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-21
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
82
00
3
0
03
00
4
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
10. Auto White Balance Check 
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0, 0.4 and 0.1
Measurement Point
Video terminal of
Displayed data of
A/V OUT jack
page: 1 (Note 2)
(75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjusting remote
commander
Specified Value
Fig. 6-1-13
LV data:
(A) and (B)
less than 0BC0
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
                    1:XX:XX
Displayed data
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting)
(CCD-TRV318/TRV418/TRV418E only) ....................... OFF
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
2
6
82
01
  INDOOR luminance point check
3
6
01
0F
Press PAUSE button.
4
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-13
(A).
5
6
01
00
Press PAUSE button.
  OUTDOOR luminance point check
6
6
01
3F
Press PAUSE button.
7
Place the C14 filter on the
lens.
8
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-13
(B).
9
6
01
00
Press PAUSE button.
  LV data check
10
Remove the C14 filter, and
place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
11
6
01
0F
Press PAUSE button.
12
Wait for 2 second.
13
0
03
06
14
1
Check that the displayed data
(Note 2) satisfied the LV data
specified value.
R-Y
2 mm
B-Y
2 mm
R-Y
B-Y
0.5 mm
1 mm
3 mm
3 mm
Fig. 6-1-13 (A)
Fig. 6-1-13 (B)
CCD-TRV118/TRV218E/TRV318/TRV418/TRV418E
6-22
11. Angular Velocity Sensor Output Check and
Steadyshot Check (CCD-TRV318/TRV418/TRV418E)
RadarW
RadarW
RadarW
Check the angular velocity sensor output.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA
Type B
ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2700 to 5100
YAW data: 2700 to 5100
Note:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting:
1) ZOOM ..................................................................... TELE end
2) STEADYSHOT (Menu setting) ........................................ ON
Checking method:
Order Page Address Data
Procedure
  PITCH sensor output check (SE751 of SI-035 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note) satisfies the PITCH
data specified value.
  YAW sensor output check (SE752 of SI-035 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note) satisfies the YAW data
specified value.
5
0
03
00
  Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.