5-26
CCD-TRV107E/TRV108E/TRV208E/TRV408E
4. COM AMP Adjustment (PD-156 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5502 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
7
Adjustment Address
48
Specified Value
A = 6.20 ± 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
48
Change the data and set the
PANEL COM signal level (A) to
the specified value.
3
7
48
Press PAUSE button.
4
0
01
00
Set the data.
5. V-COM Adjustment (PD-156 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
7
Adjustment Address
45
Specified Value
The brightness difference between the
section A and section B is minimum.
Note:
This adjustment should be carried out upon completion of the
following adjustments.
RGB AMP Adjustment
Contrast Adjustment
COM AMP Adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
45
Change the data so that the
brightness of the section A and
that of the section B is equal.
3
7
45
Subtract 8 from the data.
4
7
45
Press PAUSE button.
5
0
01
00
Set the data.
Fig. 5-1-18.
A
2H
Fig. 5-1-19.
A
A
A
A
B
B
B
B
5-27
CCD-TRV107E/TRV108E/TRV208E/TRV408E
6. White Balance Adjustment (PD-156 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
7
Adjustment Address
49, 4A
Specified Value
The LCD screen should not be colored.
Note:
Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
49
60
Set the data, and press PAUSE
button.
3
7
4A
65
Set the data, and press PAUSE
button.
4
7
49
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
7
49
Change the data so that the LCD
screen is not colored.
6
7
49
Press PAUSE button.
7
7
4A
Change the data so that the LCD
screen is not colored.
8
7
4A
Press PAUSE button.
9
7
4A
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
5-28
CCD-TRV107E/TRV108E/TRV208E/TRV408E
5-2. MECHANISM SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video
Mechanism Adjustment Manual IX   M2000 Mechanism ”.
2-1. ADJUSTMENT REMOTE COMMANDER
Connect the adjustment remote commander to CN713 of VC-272
board via CPC jig for SB (J-6082-539-A). To operate the adjustment
remote commander, connect the AC power adapter (8.4Vdc) to the
DC IN jack of CPC jig for SB, or connect the L series Info-LITHIUM
battery to the battery terminal of CPC jig for SB.
2-2. OPERATING WITHOUT  CASSETTE
1)
Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2)
Connect the adjustment remote commander.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without loading a cassette and
complete loading.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: F, address: 20, set data: 01, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette.
Be sure to carry out “Processing after Operations” after
checking the operations.
Set the data of page: D, address: 10 to the following if the
sensor ineffective mode, forced VTR power supply On mode
or forced camera power supply ON mode are to be used
together.
Forced VTR power ON mode ........................................ 12
Forced camera power ON mode .................................... 11
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-3. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape path face (tape guide, capstan shaft, pinch roller).
2)
Connect the adjustment remote commander.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: F, address: 20, set data: 08, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after
completing adjustments.)
6)
Connect the oscilloscope to CPC jig for SB.
Channel 1: PB RF (Pin 9 of CN713)
External trigger: SWP (Pin 5 of CN713)
7)
Playback the alignment tape for tracking. (WR5-1CP)
8)
Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume “8mm
Video Mechanical Adjustment Manual IX  M2000 Mechanism ”.
9)
Perform “Processing after operations”, after completing
adjustment.
Test point of CPC jig for SB
Note:
Pin No. are those of CN713.
Table 5-2-1.
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Remove the power supply from the unit.
Fig. 5-2-1.
CH1
Entrance 
side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
V
Pin No.
14
9
3
5
4
Signal Name
BL
EVF VG
PB RF (MON)
BPF MONI
TMS
TDI
SWP
CAP FG
Pin No.
15
6,8,10
7
2
Signal Name
EVF VCO
BL 4.75
GND
REC RF (RF IN)
TDO
TCK
IR VIDEO
5-29
CCD-TRV107E/TRV108E/TRV208E/TRV408E
5-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1. Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) PAL alignment tapes
• For tracking adjustment (WR5-1CP)
Parts code : 8-967-995-07
• For video frequency characteristics adjustment (WR5-7CE)
Parts code : 8-967-995-18
• For checking Standard 8 mode operations
For LP (WR5-4CL)
Parts code : 8-967-995-56
For SP (WR5-5CSP)
Parts code : 8-967-995-47
Note:
The following alignment tapes can also be used.
1)
WR5-3CL (8-967-995-36)
2)
WR5-4CSP (8-967-995-46)
• For checking Hi8 mode operations
For LP (WR5-8CLE)
Parts code : 8-967-995-57
For SP (WR5-8CSE)
Parts code : 8-967-995-48
• For BPF adjustment (WR5-11CS)
Parts code : 8-967-995-76
12) Adjustment remote commander (J-6082-053-B)
13) CPC jig for SB (J-6082-539-A)
Page of 127