DOWNLOAD Sony CCD-TRV107E / CCD-TRV108E / CCD-TRV208E / CCD-TRV408E Service Manual ↓ Size: 15.08 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV107E CCD-TRV108E CCD-TRV208E CCD-TRV408E
Pages
127
Size
15.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv107e-ccd-trv108e-ccd-trv208e-ccd-trv408e.pdf
Date

Sony CCD-TRV107E / CCD-TRV108E / CCD-TRV208E / CCD-TRV408E Service Manual ▷ View online

5-10
CCD-TRV107E/TRV108E/TRV208E/TRV408E
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60 to 61
62
63
64 to 68
69
6A to 72
73
74
75
76
77 to 79
7A
7B to 85
86
87 to 93
94
95 to AB
AC
AD to AE
AF
B0
B1
B2
B3 to B6
B7
B8
B9 to C2
C3
C4 to DB
DC
DD
DE
DF
E0
E1
E2
E3
E4 to E8
E9
EA
EB
EC
ED
EE
EF to F1
F2
F3
F4 to FF
00
00
00
83
0A
00
50
62
62
D7
D7
A0
A6
80
FC
F2
11
33
Flange back adj.
Fixed data-2
Flange back adj.
CAP FG offset adj.
Switching position adj.
Fixed data-1
AFC fo adj.
Y OUT level adj.
C OUT level adj.
Fixed data-1
REC Y current adj.
Fixed data-1
REC C/AFM current adj.
Fixed data-1
1.5MHz deviation adj.
BPF fo adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial data
Address
Remark
Initial data
Table. 5-1-3.
F page
5-11
CCD-TRV107E/TRV108E/TRV208E/TRV408E
Address
Remark
00 to 06
07
08 to 09
0A
0B
0C
0D
0E
0F
10 to 15
16
17 to 1E
1F
20
21
22 to 23
24
25
26
27 to 39
3A
3B to 42
43
44 to 50
51
52
53
54
55 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00 to 2C
2D
2E to 30
31
32
33
34
35
36
37 to 39
3A
3B to 40
41
42
43
44
45
46
47
48
49
4A
4B
4C to 53
54
55
56 to 6B
A0
2F
6E
63
8E
29
C3
60
65
50
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-1
COM AMP adj.(LCD)
White balance adj.(LCD)
Contrast adj.(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial data
5. E  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F, 7
Page Data”.)
Table. 5-1-4
6. 7  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F, 7
Page Data”.)
Table. 5-1-5.
5-12
CCD-TRV107E/TRV108E/TRV208E/TRV408E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
30, 31, 32
Specified Value 1
86 to 8A
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
88
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note2)
6
6
01
00
Set the data, and press PAUSE
button.
Note2:
The adjustment data will be automatically input to page: F, address:
30, 31, 32.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
RadarW
RadarW
RadarW
5-13
CCD-TRV107E/TRV108E/TRV208E/TRV408E
2. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 55, 58
Note1:
Dark Siemens star chart.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
1/4 CCD model: CCD-TRV408E
1/6 CCD model: CCD-TRV107E/TRV108E/TRV208E
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Adjusting method for 1/4 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
86
Write down the data.
3
F
86
00
Set the data and press PAUSE
button.
4
6
01
13
Set the data, and press PAUSE
button.
5
6
01
27
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note5)
7
F
86
Set the data that is written down
at step 2 and press PAUSE button.
Note5:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Adjusting method for 1/6 CCD model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
6
01
27
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
RadarW
RadarW
RadarW
RadarW
RadarW
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig. 5-1-7.
Page of 127
Display

Click on the first or last page to see other CCD-TRV107E / CCD-TRV108E / CCD-TRV208E / CCD-TRV408E service manuals if exist.