5-18
1-4. LCD SYSTEM ADJUSTMENT
Note:
When replacing the LCD unit, be careful to prevent damages caused
by static electricity.
[Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in CN152 of the VC-205 board.
Connect the Measuring Instruments and adjustment remote
commander via the CPC 11 jig (J-6082-425-A). To operate the
adjustment remote commander, connect the DC input lands of
CPC 11 jig to the DC power supply (6.0 to 7.2Vdc).
The following table shows the Pin No. and signal name of the
connector.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Signal name
LANC OUT
PANEL Y
LANC IN
AFC F0
REC RF
PB RF
RF AGC IN
REG GND
RF AGC OUT
BPF MONI
RF SWP
PANEL H START
PANEL VR
PANEL COM
PANEL VB
PANEL VG
1. LCD Initial Data Input
Mode
Standby
Subject
Arbitrary
Adjustment Page
E
Adjustment Address
A5 to A7, AE to B8, C0 to CD,
CF to D8
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: E, and input the data in the following table.
Note:
 To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
3)
Select page: 0, address:01, and set data: 00.
Address
A5
A6
A7
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
NTSC
60
AC
AA
00
C8
3F
C8
1F
1F
00
00
F0
4E
08
53
03
9C
32
01
02
01
01
7D
42
01
01
01
02
A1
82
9C
7D
70
98
92
8B
D5
80
PAL
60
AC
AA
00
C8
3F
C8
1F
1F
00
00
D0
4E
08
53
03
9C
32
01
02
01
01
7D
42
01
01
01
02
A1
82
9C
7D
70
98
92
8B
D5
80
Remark
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
White balance adj.
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
White balance adj.
Fixed value
Fixed value
Fixed value
Fixed value
Fixed value
Bright adj.
Color adj.
White balance adj.
White balance adj.
Contrast adj.
D range adj.
V-COM level adj.
VCO adj.
V-COM adj.
Fixed value
Data
Fig. 5-1-11.
CPC 11 jig
(J-6082-425-A) 
Remove the cover.
Conductor side
5-19
2. VCO Adjustment (PD-99 Board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!™ of CN152 (PANEL H START)
of VC-205 board
Measuring Instrument
Frequency counter
Adjustment Page
E
Adjustment Address
D6
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Note 1:
NTSC model : CCD-CR1
PAL model
: CCD-CR1E
Note 2:
The power supply voltage should be 4.2Vdc.
(Use the AC power adapter or adjust the regulated power supply
 output voltage to 4.2Vdc.)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 5D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 01.
4)
Select page: E, address: D6, change the data and set the
frequency (f) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 2, address: 7D, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
3. D range Adjustment (PD-99 Board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!§ of CN152 (PANEL VG) of
VC-205 board
External trigger : Pin 
!¢ of CN152
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D4
Specified Value
A = 3.30 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 00.
4)
Select page: E, address: D4, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-13.
A
2H
Pedestal
Pedestal
5-20
4. Bright Adjustment (PD-99 Board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!§ of CN152 (PANEL VG) of
VC-205 board
External trigger : Pin 
!¢ of CN152
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
CF
Specified Value
A = 1.90 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 40.
4)
Select page: E, address: CF, change the data and set the voltage
(A) between the pedestal and while to the specified value. (The
data of address: CF should be “9F” to “BF”.)
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 2, address: 7D, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
9)
Perform “Contrast Adjustment”.
Fig. 5-1-14.
A
2H
White
Pedestal
5. Contrast Adjustment (PD-99 Board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!§ of CN152 (PANEL VG) of
VC-205 board
External trigger : Pin 
!¢ of CN152
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D3
Specified Value
A = 3.30 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 00.
4)
Select page: E, address: D3, change the data and set the voltage
(A) between the pedestal (0 IRE) and 100 IRE to the specified
value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
8)
Check that the specified value of “Bright Adjustment” is
satisfied. If not, perform the adjustment”.
Fig. 5-1-15.
A
2H
100 IRE
Pedestal
5-21
6. V-COM Level Adjustment (PD-99 Board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!¢ of CN152 (PANEL COM) of
VC-205 board
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D5
Specified Value
A = 7.00 ± 0.05V
Note:
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 00.
4)
Select page: E, address: D5, change the data and set the PANEL
COM signal level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-16.
A
2H
7. Color Adjustment (PD-99 Board)
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
!§ of CN152 (PANEL VG) of
VC-205 board
External trigger : Pin 
!¢ of CN152
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D0
Specified Value
A = 0.30 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 57, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 20.
4)
Select page: E, address: D0, change the data and set the voltage
(A) between the green and white to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 2, address: 7D, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-17.