Sony CCD-CR1 / CCD-CR1E (serv.man2) Service Manual ▷ View online
5-30
5. RP Filter f
0
Adjustment (VC-205 Board)
Adjust the LPF of the playback RF amplifier.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin
9 of CN152 (RF AGC OUT)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
4E
Specified Value
14.2 MHz signal level is minimum
Connection:
1)
1)
Input a 14.2 MHz, 400mVp-p CW signal to Pin
7 of CN152
(RF AGC IN).
Fig. 5-2-5.
Adjusting method for NTSC model:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 35, and press the PAUSE
button.
button.
4)
Select page: F, address: 4E, change the data and minimize the
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
5)
Press the PAUSE button.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 00, and press the PAUSE
button.
button.
8)
Select page: 0, address: 01, and set data: 00.
Adjusting method for PAL model:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 35, and press the PAUSE
button.
button.
4)
Select page: F, address: 4E, change the data and minimize the
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
5)
Press the PAUSE button.
6)
Select page: F, address: 4E, and read the data (D
1
).
7)
Convert D
1
to decimal notation, and obtain D
1
'. (Refer to Table
5-3-1. “Hexadecimal-decimal conversion table” of “5-3. Service
mode”. )
mode”. )
8)
Calculate D
2
' using following equations (decimal calculation).
D
2
' = D
1
'-30
9)
Convert D
2
' to a hexadecimal number and obtain D
2
.
10) Select page: F, address: 4E, set data: D
2
, and press the PAUSE
button.
11) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
12) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
13) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-6.
Signal
generator
generator
14.2MHz 400mVp-p
0.01
µ
F
0.01
µ
F
47
Ω
15k
Ω
3.3k
Ω
Pin
3
of LANC jack
(5.5Vdc)
Pin
7
of CN152
(RF AGC IN)
Pin
8
of CN152
(REG GND)
Transistor : General NPN transistor (2SC403. etc)
47
47
Ω
resistor :
1-249-401-11
3.3 k
Ω
resistor :
1-249-423-11
15 k
Ω
resistor :
1-249-431-11
0.01
µ
F capacitor :
1-101-004-00
A
14.2MHz
5-31
6. REC Y Current Adjustment (VC-205 Board)
Adjust the Y FM signal recording current.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
55
Specified Value
A=170 ± 5mV (NTSC)
A=170 ± 5mV (PAL)
A=170 ± 5mV (PAL)
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
button.
4)
Select page: F, address: 60, after note down the data , set data:
00, and press the PAUSE button.
00, and press the PAUSE button.
5)
Select page: F, address: 55, change the data and set the Y signal
level (A) to the specified value.
level (A) to the specified value.
6)
Press the PAUSE button.
7)
Select page: F, address: 60, set the data noted down at step 4),
and press the PAUSE button.
and press the PAUSE button.
8)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
button.
9)
Select page: D, address: 10, set data: 00, and press the PAUSE
button.
button.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-7.
7. REC L Level Adjustment (VC-205 Board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, If too high, color beats will be produced on the self-
recording / playback image.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, If too high, color beats will be produced on the self-
recording / playback image.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
60, 5F
Specified Value
A=8.0 ± 0.6mV (NTSC)
A=7.5 ± 0.6mV (PAL)
A=7.5 ± 0.6mV (PAL)
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 61, and set data: 30.
4)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
button.
5)
Select page: F, address: 55, after note down the data , set data:
00, and press the PAUSE button.
00, and press the PAUSE button.
6)
Select page: F, address: 65, set data: 00, and press the PAUSE
button.
button.
7)
Select page: F, address: 60, change the data and set the REC
AFM signal level (A) to the specified value.
AFM signal level (A) to the specified value.
8)
Press the PAUSE button.
9)
Select page: F, address: 5F, set the same data as page: F, address:
60 and press the PAUSE button of the adjustment remote
commander.
60 and press the PAUSE button of the adjustment remote
commander.
10) Select page: F, address: 55, set the data noted down at step 5),
and press the PAUSE button.
11) Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
12) Select page: 2, address: 61, and set data: 00.
13) Select page: D, address: 10, set data: 00, and press the PAUSE
13) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
15) Perform “REC C Current Adjustment”.
15) Perform “REC C Current Adjustment”.
Fig. 5-2-8.
A
0.2
µ
sec
Center of the luminance width
Center of the luminance width
A
0.67
µ
sec
Center of the luminance line width
Center of the luminance line width
5-32
8. REC C Current Adjustment (VC-205 Board)
Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noise will increase and white modulation noise
will be produced.
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noise will increase and white modulation noise
will be produced.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
65
Specified Value
A=30.9 ± 1.0mV (NTSC)
A=27.6 ± 1.0mV (PAL)
A=27.6 ± 1.0mV (PAL)
Connection:
1)
1)
Disconnect CN151 of VC-205 board.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 2, address: 61, and set data: 30.
4)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
button.
5)
Select page: F, address: 55, after note down the data , set data:
00, and press the PAUSE button.
00, and press the PAUSE button.
6)
Select page: F, address: 65, change the data and set the REC
chroma signal level (A) to the specified value.
chroma signal level (A) to the specified value.
7)
Press the PAUSE button.
8)
Select page: F, address: 55, set the data noted down at step 5),
and press the PAUSE button.
and press the PAUSE button.
9)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
button.
10) Select page: 2, address: 61, and set data: 00.
11) Select page: D, address: 10, set data: 00, and press the PAUSE
11) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
12) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-9.
A
1.35
µ
sec
5-33
Fig. 5-2-10.
Recording
Audio oscillator
Attenuator
600
Ω
600
Ω
: 270
Ω
(1-249-410-11) + 330
Ω
(1-249-411-11)
Main unit
AUDIO/
VIDEO
AUDIO INPUT (Red)
AUDIO OUTPUT (White)
47k
Ω
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k
Ω
(1-249-437-11)
Playback
Main unit
AUDIO/
VIDEO
AUDIO INPUT (Red)
AUDIO OUTPUT (White)
47k
Ω
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k
Ω
(1-249-437-11)
2-4. AUDIO SYSTEM ADJUSTMENT
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments as shown in Fig.
5-2-10.
5-2-10.
[How to record the 400Hz, –7.5dBs audio signal]
Before adjusting the audio system, prepare a video cartridge which
is recorded 400Hz, –7.5dBs audio signal.
is recorded 400Hz, –7.5dBs audio signal.
Note :
To record the audio signal on a video cartridge, use another main
unit which is adjusted correctly.
unit which is adjusted correctly.
Recording method:
1)
1)
Install a video cartridge.
2)
Connect the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 73 and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
4)
Input the 400Hz, –7.5dBs signal in the audio input terminal of
AUDIO VIDEO jack.
AUDIO VIDEO jack.
5)
Press the START/STOP button and set to camera recording
mode.
mode.
6)
Record the signal for a few minutes.
After completing recording, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.
00, and press the PAUSE button of the adjustment remote
commander.