5-30
5. RP Filter f
0
 Adjustment (VC-205 Board)
Adjust the LPF of the playback RF amplifier.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
9 of CN152 (RF AGC OUT)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
4E
Specified Value
14.2 MHz signal level is minimum
Connection:
1)
Input a 14.2 MHz, 400mVp-p CW signal to Pin 
7 of CN152
(RF AGC IN).
Fig. 5-2-5.
Adjusting method for NTSC model:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 35, and press the PAUSE
button.
4)
Select page: F, address: 4E, change the data and minimize the
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
5)
Press the PAUSE button.
6)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 00, and press the PAUSE
button.
8)
Select page: 0, address: 01, and set data: 00.
Adjusting method for PAL model:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 35, and press the PAUSE
button.
4)
Select page: F, address: 4E, change the data and minimize the
14.2 MHz signal level (A).
(The data of address: 4E should be the maximum value which
satisfied the specified value.)
5)
Press the PAUSE button.
6)
Select page: F, address: 4E, and read the data (D
1
).
7)
Convert D
1
 to decimal notation, and obtain D
1
'. (Refer to Table
5-3-1. “Hexadecimal-decimal conversion table” of “5-3. Service
mode”. )
8)
Calculate D
2
' using following equations (decimal calculation).
D
2
' = D
1
'-30
9)
Convert D
2
' to a hexadecimal number and obtain D
2
.
10) Select page: F, address: 4E, set data: D
2
, and press the PAUSE
button.
11) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
12) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
13) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-6.
Signal 
generator
14.2MHz 400mVp-p
0.01
µ
F
0.01
µ
F
47
15k
3.3k
Pin 
3
 of LANC jack  
(5.5Vdc)
Pin 
7
 of CN152
(RF AGC IN)
Pin 
8
 of CN152
(REG GND)
Transistor : General NPN transistor (2SC403. etc)
47 
 resistor :
1-249-401-11
3.3 k
 resistor :
1-249-423-11
15 k
 resistor :
1-249-431-11
0.01
µ
F capacitor :
1-101-004-00
A
14.2MHz
5-31
6. REC Y Current Adjustment (VC-205 Board)
Adjust the Y FM signal recording current.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
55
Specified Value
A=170 ± 5mV (NTSC)
A=170 ± 5mV (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
4)
Select page: F, address: 60, after note down the data , set data:
00, and press the PAUSE button.
5)
Select page: F, address: 55, change the data and set the Y signal
level (A) to the specified value.
6)
Press the PAUSE button.
7)
Select page: F, address: 60, set the data noted down at step 4),
and press the PAUSE button.
8)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
9)
Select page: D, address: 10, set data: 00, and press the PAUSE
button.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-7.
7. REC L Level Adjustment (VC-205 Board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, If too high, color beats will be produced on the self-
recording / playback image.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
60, 5F
Specified Value
A=8.0 ± 0.6mV (NTSC)
A=7.5 ± 0.6mV (PAL)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 61, and set data: 30.
4)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
5)
Select page: F, address: 55, after note down the data , set data:
00, and press the PAUSE button.
6)
Select page: F, address: 65, set data: 00, and press the PAUSE
button.
7)
Select page: F, address: 60, change the data and set the REC
AFM signal level (A) to the specified value.
8)
Press the PAUSE button.
9)
Select page: F, address: 5F, set the same data as page: F, address:
60 and press the PAUSE button of the adjustment remote
commander.
10) Select page: F, address: 55, set the data noted down at step 5),
and press the PAUSE button.
11) Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
12) Select page: 2, address: 61, and set data: 00.
13) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
15) Perform “REC C Current Adjustment”.
Fig. 5-2-8.
A
0.2 
µ
sec
Center of the luminance width
Center of the luminance width
A
0.67
µ
sec
Center of the luminance line width
Center of the luminance line width
5-32
8. REC C Current Adjustment (VC-205 Board)
Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noise will increase and white modulation noise
will be produced.
Mode
Standby
Subject
Arbitrary
Measurement Point
Pin 
5 of CN152 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
65
Specified Value
A=30.9 ± 1.0mV (NTSC)
A=27.6 ± 1.0mV (PAL)
Connection:
1)
Disconnect CN151 of VC-205 board.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 61, and set data: 30.
4)
Select page: 3, address: 01, set data: 43, and press the PAUSE
button.
5)
Select page: F, address: 55, after note down the data , set data:
00, and press the PAUSE button.
6)
Select page: F, address: 65, change the data and set the REC
chroma signal level (A) to the specified value.
7)
Press the PAUSE button.
8)
Select page: F, address: 55, set the data noted down at step 5),
and press the PAUSE button.
9)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
10) Select page: 2, address: 61, and set data: 00.
11) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
12) Select page: 0, address: 01, and set data: 00.
Fig. 5-2-9.
A
1.35 
µ
sec
5-33
Fig. 5-2-10.
Recording 
Audio oscillator
Attenuator
600 
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
Main unit
AUDIO/
VIDEO
AUDIO INPUT (Red)
AUDIO OUTPUT (White) 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k 
 (1-249-437-11)
Playback
Main unit
AUDIO/
VIDEO
AUDIO INPUT (Red)
AUDIO OUTPUT (White) 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k 
 (1-249-437-11)
2-4. AUDIO SYSTEM ADJUSTMENT
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments as shown in Fig.
5-2-10.
[How to record the 400Hz, –7.5dBs audio signal]
Before adjusting the audio system, prepare a video cartridge which
is recorded 400Hz, –7.5dBs audio signal.
Note :
To record the audio signal on a video cartridge, use another main
unit which is adjusted correctly.
Recording method:
1)
Install a video cartridge.
2)
Connect the adjustment remote commander.
3)
Select page: 3, address: 01, set data: 73 and press the PAUSE
button of the adjustment remote commander.
4)
Input the 400Hz, –7.5dBs signal in the audio input terminal of
AUDIO VIDEO jack.
5)
Press the START/STOP button and set to camera recording
mode.
6)
Record the signal for a few minutes.
After completing recording, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.