Sony SDM-E76A / SDM-E76D / SDM-E96A / SDM-E96D Service Manual ▷ View online

EDID DATA for E96A/D
 
 
EDID data for SDM-E96D (Analog) 
 
 
 
EDID data for SDM-E96D (Digital) 
 
 
 
 
                                                                                          9                                           
SDM-E76A,D / SDM-E96A,D(E)        
 
EDID data for SDM-E96A (Analog) 
 
 
 
     
                   
   
                             
       
                               
               
   
 
   
 
 
 
 
   
 
 
                                                                                          10                                           
SDM-E76A,D / SDM-E96A,D(E)        
 
OPERATING INSTRUCTIONS                          
 
<Key Control> 
 
 
 
 
<Common Adjustment> 
                                                                                          11                                           
SDM-E76A,D / SDM-E96A,D(E)        
 
SERVICE MODE
 
 
To enter service OSD menu, 
1) Turn off the power switch button. 
2) Press “Down” key, and power key simultaneity. 
3) Shows the service OSD menu. That menu is located in down side of main menu. 
4) The service OSD menu contains additional menus as described below. 
 
 
 
Service Mode Explanations 
 
COLOR TEMP 
Adjust R/G/B color values of contrast and brightness in 9300k, 6500k, Use color mode.   
(Factory Setting Area). 
 
INITIAL EEPROM 
Initialize the EDID DATA at DDC2B EEPROM is saved system memory. 
COLOR TEMP data becomes the default “128”. User table data is reset. 
 
CLR. ETI 
ETI  (the used time of MNT) counter shall be reset to 0H by activating this function.   
 
AGING 
Enable to set the monitor in the Aging mode or exit from the mode. Select aging mode (On/Off) 
 
WHITE BALANCE 
Adjust the offset voltage and gain value in Analog RGB by AUTO. 
 
DEFAULT TIMING 
Select the resolution timing of the signal. Menu is 1152×864(VESA standard timing) or   
1152×870(MAC computer timing).    Default is 1152×870. 
 
MODULE 
To select applied module 
When you replace A board or Panel, it is required to set the Panel inch size and the Panel maker name on 
selecting “MODULE”.   