DOWNLOAD Sony CPD-200GS (serv.man2) Service Manual ↓ Size: 1.12 MB | Pages: 33 in PDF or view online for FREE

Model
CPD-200GS (serv.man2)
Pages
33
Size
1.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor / S/M CPD-200GS''97 US CAN
File
cpd-200gs-sm2.pdf
Date

Sony CPD-200GS (serv.man2) Service Manual ▷ View online

— 17 —
CPD-200GS
  
   
 Vertical and Horizontal Position and Size
    
  Specification
2
1
2
1
G
G
R
B
3.     Receive White cross-hatch.
4.     Adjust HMC and VMC at six-pole magnet.
        < 6 Pole Magnet>
5.     Receive R.B. cross-hatch.
6.     Adjust H.TILT by swinging the DY neck right and left.
7.     Adjust XCV with XCV core.
                           XCV movement
R
B
B
R
R
B
b
b
a
a
A
B
A      0.24mm
B      0.30mm
B
A
Focus (V)
FBT
YCH
TLV
XCV
Horizontal and Vertical
a < 2.5 mm
b < 2.5 mm
  A         B
202      270
2
7
0
4
6
1
5
3
9
8
12
11
YBH-B
YBH-T
CBH-RT
MBH-RT
APH-R
MBH-RB
CBH-RB
CBH-LB
MBH-LB
APH-L
MBH-LT
CBH-LT
Adjust each misconvergence point in sequence.
H STAT
11.      Digital Convergence Adjustment
      
     A.  Horizontal Convergence
2
7
0
4
6
1
5
3
9
8
12
11
V STAT-B
V STAT-T
CCV-RT
MCV-RT
XBV-R
MCV-RB
CCV-RB
CCV-LB
MCV-LB
XBV-L
MCV-LT
CCV-LT
Adjust each misconvergence point in sequence.
V STAT
8.     Adjust V.TILT with TLV VR.
         TLV movement
9.     Adjust Y.CROSS with YCH VR.
         YCH movement
10.     Paint lock the four-pole and six-pole Mg.
          <VR Adjustment on DY>
<Zero Position NECK Ass'y>
                 Purity
       4-Pole Mg              6-Pole Mg
0.30mm
0.30mm
R
B
B
R
      
Convergence Specification
 
     Focus adjustment
       Adjust focus (V) and focus (H) for optimum focus.
B.  Vertical Convergence
C.  Repeat the procedure of A and B so that the
      convergence of the whole screen is within the
      specification.
Focus (H)
Focus (v)
Focus (V)
FBT
Focus (H)
— 18 —
CPD-200GS
5-2.  CIRCUIT BOARDS LOCATION
Note:
•  All capacitors are in 
µ
F unless otherwise noted. pF: 
µµ
F
    50 WV or less are not indicated except for electrolytic.
•  Indication of resistance, which does not have one for rating
      electrical power, is as follows.
•    All resistors are in ohms.
•   
f
 : nonflammable resistor.
•   
F
 
:
 fusible resistor.
      
     : internal component.
    
p
 
: 
panel designation and adjustment for repair.
•   
 e    : 
earth-ground.
•   
 E    : 
earth-chassis.
•  The components identified by 
[  in this basic schematic
    diagram have been carefully factory-selected for each set
    in order to satisfy regulations regarding X-ray radiation.
   Should replacement be required, replace only with the
      value originally used.
•    When replacing components identified by
 
]
,
 make the necessary
      adjustments by using RV501 (
[) as indicated.   (See page 15)
•   All variable and adjustable resistors have characteristic curve B,
      unless otherwise noted.
•   When replacing parts shown in the table below,
     be sure to perform the safety related adjustment.
              Part Replaced (
[)
                    
  RV501
              Part Replaced (
])
All voltages are in volts.
Readings are taken with a 10 
ΜΩ
 digital multimeter
Readings are taken with a color-bar signal input.
Voltage variations may be noted due to normal
production tolerances.
•            *
: Cannot be measured.
Circled numbers are waveform references.
: B +bus.
: B - bus.
          Pitch: 5 mm
          Rating electrical power 1/4 W (CHIP: 1/10 W)
    Note: The components identified by shading and
mark 
¡
     
are critical for safety. Replace only
with part number specified.
Note:  Les composants identifies per un trame et une
marque 
¡
 sont critiques pour la securite.  Ne les
remplacer que par une piece portant le numero specifie.
5-3.  SCHEMATIC DIAGRAMS AND PRINTED WIRING BOARDS
D - BOARD
RV501, T501, R545, R546, R548,
R550, R547, R549, R552, D517,
IC605, IC901, C540, C542, C544,
C541, C535, IC501, C558, R567,
R564, C555, C553, C554, C561
D
A
J
Page of 33
Display

Click on the first or last page to see other CPD-200GS (serv.man2) service manuals if exist.