Sony CPD-200GS (serv.man2) Service Manual ▷ View online
— 13 —
CPD-200GS
2-3. D, A and J BOARD REMOVAL
2-1. CABINET REMOVAL
2-2. SERVICE POSITION
SECTION 2
DISASSEMBLY
1
3
4
Two screws
(BVTP 4 x 16)
Cabinet
Two claws
PUSH
PUSH
2
Two audio jacks**
**Caution: To avoid breakage, gently pull
sides of cabinet out and over the audio
jacks when removing cabinet from
chassis.
sides of cabinet out and over the audio
jacks when removing cabinet from
chassis.
Cable bracket
Cable stopper
Five screws
(BVTP 3 x 12)
D board
One screw
(BVTT 4 x 8)
1
4
5
7
3
8
A board
Two screws
(BVTP 3 x 12)
6
J board
2
1
2
3
A board
D board
— 14 —
CPD-200GS
2-4. PICTURE TUBE REMOVAL
Turn up one side of the rubber cap in
the direction indicated by arrow
.
When one side of the rubber cap sepa-
rates from the anode button, the anode-
cap can be removed by turning the rub-
ber cap and pulling it in the direction of
arrow
cap can be removed by turning the rub-
ber cap and pulling it in the direction of
arrow
.
Use your thumb to pull the rubber cap
firmly in the direction indicated by
arrow
arrow
.
HOW TO HANDLE AN ANODE-CAP
REMOVAL OF THE ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
removing the anode.
REMOVAL PROCEDURES
Do not use sharp objects which may cause damage to the surface
of the anode-cap.
Do not squeeze the rubber covering too hard to avoid damaging
the anode-cap. A material fitting called a shatter-hook terminal is
built into the rubber.
built into the rubber.
Do not force turn the foot of the rubber cover. This may cause the
shatter-hook terminal to protrude and damage the rubber.
Demagnetization coil
Tension spring
Stand assy
(D board)
A board
Neck assy
Deflection yoke
Four screws
(Tapping screw 5)
Anode cap
Cushion
Picture tube shield
Two screws
(BVTP 4 x 16)
1
6
9
10
5
4
3
2
7
8
— 15 —
CPD-200GS
b) HV Hold-Down Check
1) Using an external DC Power supply, apply the
voltage shown below between cathode of D517
o n " D " Board and GND, and confirm that the
HV Hold-Down circuit works. (Raster disappears)
o n " D " Board and GND, and confirm that the
HV Hold-Down circuit works. (Raster disappears)
Apply DC Voltage: 31.4 + 0.01 VDC
Check Condition
• Input voltage
• Input voltage
: 120 + 2 VAC
• Input signal
: (fH = 64 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (center)
• B+ Voltage
: 185.0 + 3.0 VDC
c) Beam Protector Check (Software logic)
1) Using an external DC power supply, apply the
voltage 8.8 + 0.01 VDC between pin 11 of FBT
(T501) and GND, and confirm that the voltage
across C541 is 3.7 VDC or less.
(T501) and GND, and confirm that the voltage
across C541 is 3.7 VDC or less.
Check Condition
• Input voltage
• Input voltage
: 120 + 2 VAC
• Input signal
: (fH = 64 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (center)
d) B+ MAX. Check
1) Input white cross hatch (fH = 64 kHz) signal.
2) CONT (max) & BRT (center)
3) Input voltage: 120 + 2 VAC
2) CONT (max) & BRT (center)
3) Input voltage: 120 + 2 VAC
Note
: Use NF power supply or make sure that
distortion factor is 3% or less.
4) Confirm that the B+ voltage is within the voltage
range shown below.
Standard voltage: 185.0 + 3.0 VDC
SECTION 3
SAFETY RELATED ADJUSTMENT
Part Replaced (
[)
RV501
Part Replaced (
])
D - BOARD
When replacing parts shown in the table below, the
following operational checks must be performed as a
safety precaution against X-ray emissions from the unit.
Allow the unit to warm up for one minute prior to
checking the following conditions:
a
) HV Regulator Check
1) Input white cross hatch signal. (fH = 64 kHz)
2) Minimum CONT and BRT controls.
3) Cut off Screen VR (G2).
4) Input voltage: 120 + 2 VAC
5) Confirm that the voltage is within the voltage range
2) Minimum CONT and BRT controls.
3) Cut off Screen VR (G2).
4) Input voltage: 120 + 2 VAC
5) Confirm that the voltage is within the voltage range
shown below.
Standard voltage: 25.0 + 0.5KVDC
6) When replacing components identified by
], make
sure to recheck the High Voltage.
7) Verify the High Voltage as shown above (25 + 0.5KVDC)
is within specification. If not, set H. SIZE data at
minimum (-127) and then adjust RV501 on "D" Board.
minimum (-127) and then adjust RV501 on "D" Board.
8) After adjusting the High Voltage within specification,
put the RV cover on RV501 as shown below and apply
sufficient amount of RTV around RV501.
sufficient amount of RTV around RV501.
10
4
R V 5 0 1
RV501, T501, R545, R546, R548, R550, R547, R549, R552,
D517, IC605, IC901, C540, C542, C544, C541, C535,
IC501, C558, R567, R564, C555, C553, C554, C561
D517, IC605, IC901, C540, C542, C544, C541, C535,
IC501, C558, R567, R564, C555, C553, C554, C561
— 16 —
CPD-200GS
Convergence Fine Adjustment
Set DY four-pole magnet to mechanical center
before adjustment.
This should be prime mode.
before adjustment.
This should be prime mode.
1. Receive R.B. cross-hatch.
2 Adjust H.STAT and V.STAT at four-pole magnet.
2 Adjust H.STAT and V.STAT at four-pole magnet.
< 4 Pole Magnet>
SECTION 4
ADJUSTMENTS
Landing Rough Adjustment
1. Enter the full white signal.
2. Adjust the contrast to the maximum.
3. Input full green signal.
4. Moving the DY backward, and adjust coarsely the purity
2. Adjust the contrast to the maximum.
3. Input full green signal.
4. Moving the DY backward, and adjust coarsely the purity
magnet sothat a green raster positions in the center of
screen.
screen.
5. Moving the DY forward, adjust so that an entire screen
becomes pure green.
6. Adjust the tilt of DY, and tighten lightly with a clamp.
becomes pure green.
6. Adjust the tilt of DY, and tighten lightly with a clamp.
Landing Fine Adjustment
1. Place the set in the Helmholtz coil.
2. Enter a green signal only.
3. Degauss the entire screen with hand-degausser. Then auto-
degauss it.
4. Attach a wobbling coil to the specified position of CRT
neck.
5. Attach a landing adjuster sensor on the CRT.
6. Using a landing checker, adjust the DY position, purity,
tilt of DY.
7. Clamp the DY screw.
Clamping torque: 22 + 2 kgcm (2.2+ 0.2 N.m)
2. Enter a green signal only.
3. Degauss the entire screen with hand-degausser. Then auto-
degauss it.
4. Attach a wobbling coil to the specified position of CRT
neck.
5. Attach a landing adjuster sensor on the CRT.
6. Using a landing checker, adjust the DY position, purity,
tilt of DY.
7. Clamp the DY screw.
Clamping torque: 22 + 2 kgcm (2.2+ 0.2 N.m)
Convergence Rough Adjustment
1. Enter the white crosshatch signal.
2. Adjust roughly the horizontal and vertical
convergence at four-pole magnet.
3. Adjust roughly HMC and VMC at six-pole
magnet.
2. Adjust roughly the horizontal and vertical
convergence at four-pole magnet.
3. Adjust roughly HMC and VMC at six-pole
magnet.
*The parts above ( ~ ) are necessary for DAS adjustment.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
Interface Unit
2
3
D-sub
(9 Pin [female])
(9 Pin [female])
mini Din
(8Pin)
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
1
2
1
R
B
B
R
B
R B
R
B
1
2
R
B
R
B
2
1
2
1 +
2
1 +
2
1
Set the
finger
finger
Mechanical
Center
Center
NECK Assy
6-pole Mg
P.S Mg
XBV
DY
CRT
4-pole Mg
Connect the communication cable of the connector located on the D board on the monitor. Run the service software and
then follow the instructions.
then follow the instructions.
Allow a 30 minute warm-up period prior to making the following adjustments:
P.S. Mg
Click on the first or last page to see other CPD-200GS (serv.man2) service manuals if exist.