DOWNLOAD Sony DVP-K86P Service Manual ↓ Size: 5.08 MB | Pages: 79 in PDF or view online for FREE

Model
DVP-K86P
Pages
79
Size
5.08 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD / BRAZIL
File
dvp-k86p.pdf
Date

Sony DVP-K86P Service Manual ▷ View online

5-5
DVP-K86P
Pin No.
Pin name
Type
Function
200
Y/G
Output
Green signal or Y signal output
201
DACVSSA
Ground
Ground pin for Video DAC circuitry
202
B/Cb/Pb
Output
Blue signal or Cb signal output
203
R/Cr/Pr
Output
Red  signal or Cr signal output
204
DVDD3
Power
3.3V power pin for Video DAC digital circuitry
205
MIC
Input  SMT
Karaoke Microphone detect signal
206
VOICE (MV-50 only)
Output SMT
Karaoke voice function (not used)
SCORE (MV-51 only)
Input SMT
Karaoke score function
(DVP-K86P only)
ECHO_ON OFF
Output SMT
Karaoke Echo function status output (H: Echo on; L: Echo off)
(MV-51 only)
(DVP-NC65K/NC66K)
207
KRMOD
Output SMT
Karaoke Mode Status Output (H: Normal, L: Karaoke)
Output Default
208
SCK
Output
ADAC Serial Clock (S/W method by 8032)
209
WIDE
Output
Voltage select output signal for S-terminal (H:16:9, L:4:3)
Output Default
210
SDO
Output
ADAC Serial data output (S/W method by 8032)
211
xSCS
Output
Chip select for ADAC (Low active, SW method by 8032)
212
DVDD3
Power
3.3V power pin for internal digital circuitry
213
ALRCK
Output  PD,SMT
Audio left/right channel clock (ADAC LRCK output)
214
ABCK
Output
Audio Bit Clock output (ADAC BCK output)
215
ACLK
Output
Master clock output for Audio DAC (ADAC CLK Master clock output)
216
DVSS
Ground
Ground pin for internal digital circuitry
217
ASDATA0
Output
Not used
218
ASDATA1
Output
Not used
219
ASDATA2
Output
Not used
220
xRST
Default Low
Reset output signal for ADAC (Low Active)
221
DVDD18
Power
1.8V power pin for intenal digital circuitry
222
ASDATA4
Output PD,SMT
Audio serial data 4: Down-mixed L/R
223
DVSS
Ground
Ground pin for internal digital circuitry
224
Disc/XEXT (MV-50 only)
Output
Disc/External input select output signal (H: Disc, L: External)
 XVOICE (MV-51 only)
Input
Karaoke Voice function
(DVP-K86P only)
225
SPDIF
Output
SPDIF output
226
RFGND18
Ground
Ground pin for internal analog circuitry
227
RFVDD18
Power
1.8V power pin for internal analog circuitry
228
XTALO
Output
27M crystal output
229
XTALI
Input
27M crystal input
230
JITFO
Analog Output
The output terminal of RF jitter
231
JITFN
Analog Input
The input terminal of RF jitter
232
PLLVSS
Ground
Ground pin for data PLL and related analog circuitry
233
IDACEXLP
Analog Output
Data PLL DAC Low-pass filter
234
PLLVDD3
Power
3.3V power pin for data PLL and related analog circuitry
235
LPFON
Analog Output
The negative output terminal of loop filter amplifier
236
LPFIP
Analog Input
The positive input terminal of loop filter amplifier
237
LPFIN
Analog Input
The negative input of loop filter amplifier
238
LPFOP
Analog Output
The positive output of loop filter amplifier
239
ADCVDD3
Power
Power  pin for ADC circuitry
240
NC
Not used
241
ADCVSS
Ground
Ground pin for ADC circuitry
242
NC
Not used
243
NC
Not used
244
RFVDD3
Power
3.3V power pin for RF digital circuitry
245
RFRPDC
Analog Output
RF ripple detect output
246
RFRPAC
Analog Input
RF ripple detect input (through AC-coupling)
5-6
DVP-K86P
5-6E
Pin No.
Pin name
Type
Function
247
HRFZC
Analog Input
High frequency RF ripple zero crossing capasitor connecting
248
CRTPLP
Analog Output
Defect level filter capacitor connecting
249
RFGND
Ground
Ground pin for RF digital circuitry
250
NC
Not used
251
NC
Not used
252
OSP
Analog Output
RF  Offset cancellation capacitor connecting
253
OSN
Analog Output
RF  Offset cancellation capacitor connecting
254
RFGC
Analog Output
RF AGC loop capacitor conecting for DVD-ROM
255
IREF
Analog Input
Input reference current input
256
AVDD3
Power
3.3V power pin for analog circuirtry
6-1
DVP-K86P
SEÇÃO 6
MODO DE TESTE
6-1. MEDIDA DO IOP 
Para medição do IOP, execute os seguintes 
procedimento abaixo.
(1)
Em standby pressione
[TOP MENU], [CLEAR], [POWER]
para entrar no modo Remocon Diagnosis. 
Remocon Diagnosis Menu
0. External C hip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
5. Video Level A djustment
Model  
Name: x xx xxx xxx
IF-con  Ver:  xxx
Syscon  Ver: xxx
(2)
Selecione “2. Drive Manual Operation” teclando
2
no controle remoto. A nova tela sera visualizada 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual A djustment
4. Tray Aging Mode
0. Return to top Menu
(3)
Selecione "3. Manual Adjustment" teclando
3 no
controle renoto. A nova tela sera visualizada. 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(4)
Selecione Iop teclando
6 no controle remoto. 
(5)
Aguarde até aparecer os dados hexadecimal. 
Manual A djust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(6)
Converta os dados hexadecimal para decimal 
(7)
Utilize a fórmula abaixo para calcular IOP em mA 
IOP (mA)=IOP (decimal) x 0.622678.
(8)
Pressione
[RETURN] para voltar ao menu anterior. 
(9)
Pressione
- para retornar ao Top Menu e desligar o 
reprodutor de DVD. 
6-2. VERIFICAÇÃO DO HISTÓRICO DE EMERGÊNCIA
Informação do Emergency History.
(1)
Em modo de standby pressione
[TOP MENU]
,
[CLEAR]
,
[POWER]
para entrar no modo Remocon Diagnosis. 
(2)
Selec
ione “3. Emergency History”.
Emg. History Check
Laser Hours            CD   999h 59min
DVD 999h 59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
(3)
Tempo de emissão de Laser
Tempo de DVD Laser ON. (total de uso )
Tempo de CD Laser ON. (total de uso)
(4)
Histórico da Emergência. 
O histórico de erros pode ser visualizado do"1"ao "10"
pressionando a tecla
[NEXT] ou [PREV] .
(5)
Código de erro
Exemplo de codigo de Erro
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
(Verificação do Histórico de Emergência.) 
6-2
DVP-K86P
(6)
Lista dos Códigos de Erros
01:
Erro de comunicação (Sem resposta do syscon) 
02:
Syscon desativado.
03:
Power OFF é solicitado quando o syscon deixa de atuar 
19:
Desligamento térmico 
24:
Erro no deslocamento do Sled
25:
Error no movimento do Mecanismo(não usado neste modelo)
26:
Erro no movimento de Bandeja (não usado neste modelo)
30:
Erro de ajuste do  Motor DC (nao usado neste modelo)
31:
Erro no ajuste de offset do DPD
32:
Erro no ajuste do TE Balance
33.
Erro no ajuste do TE Sensor 
34.
 Erro no ajuste do ganho doTE 
35.
Erro no ajuste do ganho do FE 
36.
Jitter ruim após o ajuste
40. Focus NG
42. Focus NG
 na troca de camadas
52.
Erro na partida do spindle
51:
Erro no Spindle stop 
60:
Erro de Focus on
61:
Erro de falha do Seek
62:
Erro na leitura de Qdata/ID 
70:
Falha de leitura  do Lead In Data 
71:
Falha de leitura do TOC  (CD)
80:
Falha do  Buffer
81:
Tipo de média desconhecida 
(7)
Parametros do Código de erro 
Example of E rror code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Os numeros selecionados  informam os 
(8)
Tempo de uso do laser quando ocorreu o erro
Example of E rror code
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
Este é o tempo de uso do laser quando ocorreu o erro
(9)
Como limpar o tempo de uso do laser 
Pressione em ordem as teclas
[DISPLAY], [CLEAR]
Limpa ambos dados do CD e DVD.
Emg. History Check
Laser Hours    CD                 0 h 0 min
DVD              0 h 0 min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01 00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
(10)
Como limpar o Código de Emergência. 
Pressione em ordem as teclas
[TOPMENU], [CLEAR]
Todos os códigos da emergência são limpadas. .
Emg. History Check
Laser Hours    CD          999h 59min
DVD 999h 59min
1. 00 00 00 00
00 00 00 00
00 00 00 00 00 00 00 00
2. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
[Next] Next Page [Prev] Prev Page
6-3. INICIALIZANDO OS DADOS DE SETUP 
Como inicializar os dados de setup .
(1)
Em modo de stanby ,pressione
[TOP MENU], [CLEAR], [POWER]
para entrar no Remocon Diagnosis Mode.
(2)
       Selecione “3. Emergency History”.
Emg. History Check
Laser Hours            CD           999h    59min
DVD 999h 59min
1. 01 05 04 04
00 92 46 00
00 00 00 00
00 00 23 45
2. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
(3)
Inicializando dados de setup
Pressione em ordem as teclas
[MENU], [CLEAR]
Os dados estarão inicializados quando a mensagem
“Initialize setup data...” é mostrada.
Emg. History Check
Laser Hours             CD          999h 59min
DVD 999h 59min
Initialize setup data ...
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
códigos de erro.
Page of 79
Display