4-33
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4. In case of error display in the Focus Pattern (infinity position)
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
infinity position can be done in more than 5 seconds and no more than 20 seconds.
• When the focus pattern error
Fig.4-7-20
Fig.4-7-21
• When the lens does not reach the infinity end infinity position seconds.
Fig.4-7-22
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-34
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-8.
FOCUS HOLD BUTTON CHECK (FOCUS HOLD BUTTON)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Focus Hold Button]
.
Fig.4-8-1
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-8-2
3)
The message “Push [FOCUS HOLD] button once softly.” is displayed on the pop-up window.
Press the focus hold button.
Fig.4-8-3
4)
When the focus hold button check finishes normally, “OK” is displayed on the pop-up window.
Fig.4-8-4
4-35
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
3. In case of error display in the Focus Hold Button
1)
When the Focus Hold Button cannot be pressed within a certain period of time or the button is defective, the window below appears.
Fig.4-8-5
2)
In case of error caused by time-out of key pressing, perform the work with caution so as to press the focus hold button within a
certain period of time.
3)
Although the button is pressed within a certain period of time, if the error occurs, replace parts relating to the focus hold button.
(Refer to “2-1-5. FIXED HOLDING TUBE BLOCK AND FOCUS OPERATION RING BLOCK”)
4)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-36
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-9.
WRITE dSB
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Write dSB]
.
Fig.4-9-1
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each item.
Fig.4-9-2
3)
The “Select dsb” window appears.
4)
Being based on the image point shift amount calculated by “4-5. FOCUS-SHIFT CHECK/ADJUSTMENT (APERTURE (AMOUNT
OF SPHERICAL ABERRATION))”, select the button.
Fig.4-9-3
5)
When the Write dSB finishes normally, “OK” appears on the pop-up window.
Fig.4-9-4
Page of 83