4-9
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4. Startup of Lens Adjustment Program (ActuatorChecker.exe)
1)
Download the file “ActuatorChecker VerX.X.X.X.zip” from Service Fixture and Software of ESI homepage, save and extract it.
2)
Start up “ActuatorChecker.exe” from an arbitrary folder.
3)
If “PC-CARD-DIO48” is properly installed, the window below appears.
Note:
The version of “ActuatorCheker” might be updated.
Fig.4-1-19
4-10
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
Finished Inspection JIG
Lens
4-1-3. Connection of Finished Inspection JIG and Lens Adjustment Program
(ActuatorChecker.exe)
Note:
Confirm “4-1-2. Lens Adjustment Program (ActuatorChecker)” has been completed before this procedure is executed.
Equipment
• Personal Computer
• USB cord with connector
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1.
Connect equipment and checking lens as shown Fig.4-1-20.
Fig.4-1-20
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up “ActuatorChecker.exe” from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.
4-11
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-1-4. Initial Setting of “ActuatorChecker”
1.
Start up “ActuatorChecker.exe”.
Fig.4-1-21
2.
Depending on the initial startup or setting made at the previous startup, the window differs.When the English window appears, click
the 
[Set up]
 button.
Note:
When any button is clicked, the Serial window appears. The window to enter the lens serial number appears.
Fig.4-1-22
4-12
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
3.
Set the following contents in the SETUP window.
• MODEL
Model to be adjustment this time
• Language
English
• State
FINAL
• PROCESS
SERVICE
4.
Confirm that all of the items are set, and click [OK].
Fig.4-1-23
4-1-5. About Inspection Procedure of Lens Adjustment Program (ActuatorChecker)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the
inspection of each item one by one.
Click 
[START]
 from the start up window when you inspect the corresponding model as everything continues.
The procedure for executing the inspection of each item one by one has been described in this manual.