DOWNLOAD Sony SAL85F14Z Service Manual ↓ Size: 2.19 MB | Pages: 83 in PDF or view online for FREE

Model
SAL85F14Z
Pages
83
Size
2.19 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera
File
sal85f14z.pdf
Date

Sony SAL85F14Z Service Manual ▷ View online

4-29
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-7-2. Focus Brush Position Check (Focus Adjustment Point)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Focus Adjustment Point]
.
Fig.4-7-4
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-7-5
3)
The message “Move FOCUS to Near position. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the near position and press down the ENTER key.
Fig.4-7-6
4-30
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4)
When the Near position check finishes normally, the message “Move FOCUS to Infinity position. Then push [ENTER].” is displayed
on the pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-7-7
5)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-7-8
3. In case of error display in the Focus Adjustment Point
1)
When the error display and the NG display appear to the pop up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
• In case of error at the near position in the Focus Adjustment Point
Fig.4-7-9
Fig.4-7-10
• In case of error at the infinity position in the Focus Adjustment Point
Fig.4-7-11
Fig.4-7-12
2)
Although the lens is positioned at the near position or the infinity position, if “NG” appears, confirm or perform the following.
• 4-7-1. Focus Brush Position Adjustment
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-31
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4-7-3. Focus Brush Pattern Check(Focus Brush Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Focus Pattern]
.
Fig.4-7-13
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-7-14
3)
The message “Move FOCUS to Near position. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the near position and press down the ENTER key.
Fig.4-7-15
4-32
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
4)
When the Near position check finishes normally, the message “Move FOCUS to Infinity position at about 5sec.” is displayed on the
pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-7-16
5)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-7-17
3. In case of error display in the Focus Pattern (near position)
1)
When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-7-18
Fig.4-7-19
2)
 Although the lens is positioned at the near position, if “NG” appears, confirm or perform the following.
• 4-7-1. Focus Brush Position Adjustment
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
• Rotating operation error of the focus ring (rotation speed is not suitable at a regulated speed.).
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
Page of 83
Display