Sony SAL18552 Service Manual ▷ View online

4-8
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
3)  Connect the camera and personal computer (when using HASP Key) with USB cable and activate Defocus Checker 2 or DSLR-A700 
Defocus checker.
 
In case Defocus Checker 2 is used, click [Connect] to set connection mode.
Note:
  If an abnormal phenomenon appears during installation of the teleconverter used by the user, install the user s teleconverter.
Guidelines Table
Selection of 
Shooting magni-
fication
AF Assist Chart (Size) 
Refer to Fig. 4-5-1.
Applicable Cam-
era (image sensor 
type)
Applicable Lens
Calculation example of shoot-
ing distance 
[shooting magnification] 
×
 
[focal length] = [shooting dis-
tance]
60 times 
(middle distance)
AF Assist Chart 60 Times 
(200 mm 
×
 100 mm)
APS-C size type 
All
60 times 
×
 50 mm = 3000 mm
40 times 
(middle distance)
AF Assist Chart 40 Times 
(132 mm 
×
 66 mm)
35 mm full size type
All
40 times 
×
 50 mm = 2000 mm
20 times 
(short distance)
AF Assist Chart 20 Times 
(66 mm 
×
 33 mm)
both size available
•  Macro lens
•  Lens with a focal 
length of more 
than 300 mm
20 times 
×
 300 mm = 6000 mm
 Table 
4-5-2
 
(100 mm)
(66 mm)
(33 mm)
(200 mm)
(132 mm)
(66 mm)
AF Assist Chart
60 Times
AF Assist Chart
40 Times
AF Assist Chart
20 Times
 Fig. 
4-5-1
 
Camera Setting
Exposure mode
Focus Mode
Focus Area
Image Size
Super SteadyShot
Drive Mode
: A (Open Aperture)
: MF
: Spot Focus Area
  (Fixed at the center)
: L
: OFF
: Self-timer
Shooting distance
Set the optical axis to the center 
of the AF assist chart.
AF Assist Chart
(60 Times/40 Times)
Chart for checking the depth area of image-formation
(60 Times/40 Times)
 Fig. 
4-5-2
2. Shooting procedure
1)  Click the [Start] of Defocus Checker 2 or DSLR-A700 Defocus checker to start the measurements.
2)  Adjust defocus value to obtain  0 
μ
m  in the manual focus mode.
 
The tolerance is  0 
±
 10 
μ
m . (Fig. 4-5-3)
3)  Click the [Stop] of Defocus Checker 2 or DSLR-A700 Defocus checker.
4)  Shoot an image by self-timer.
5)  Perform the steps 1) to 4) by using the AE master lens and the lens to be tested.
Note 1: 
Shoot images with the AE master lens and the lens to be tested using the same camera.
Note 2: 
Perform entire work within 10 minutes because values become unstable as the camera temperature increases.
 
 
If the work continues for 10 minutes or longer, cool down the camera and then restart the work.
Note 3: 
Since focusing error amount increases in shooting images at a middle or long distance, comprehensive focusing error amount cannot be 
determined correctly only by results with short-distance setting. If the shooting distance using a 60 times chart cannot be ensured indoors, 
take either of the following methods.
 
 
Method 1
 
 
Use 35 mm full size type camera (SLT-A99) and 40 times chart. (When using the 40 times chart, shooting distance can shorten to 2/3 of 60 
times chart.)
 
 
Method 2
 
 
Check the focusing error amount of short distance using 20 times chart temporarily. After that, shoot the something images outdoors in the 
middle distance for using 60 times chart, and then check the focusing amount of middle distance.
 
Defocus Checker 2
(For SLT-A37/A57/A58/A65/A77/A99)
DSLR-A700 Defocus checker
(For DSLR-A700)
In case Good (0 
± less than 10 μm), frame 
of waveform area displays in green.
In case Good (0 
± less than 10 μm), frame 
of waveform area and defocus value display 
in green.
 Fig. 
4-5-3
4-9
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
3.  The focusing error amount check
1)  Open the images shot with the lens to be tested and the AE master lens by the image display software on the PC. (Display the images at 
the same pixel magnification.)
2)  Check the displacement between the focus position (peak of image-formation) of the lens to be tested and the focus position of the AE 
master lens. (Refer to Fig. 4-5-4 and Fig. 4-5-5.)
3)  Compare the error amount in step 2) with the reference value of Table 4-5-3 and check whether the error amount is within the accept-
able range. If the error amount is outside of the range, perform  4-7-5. 
SB Check/Write .
Reference value
Focal length/
18 mm
Distance
(mm)
0.36 m (20 times)
±
 23
0.72 m (40 times)
±
 92
1.08 m (60 times)
±
 208
Focal length/
24 mm
Distance
(mm)
0.48 m (20 times)
±
 26
0.96 m (40 times)
±
 106
1.44 m (60 times)
±
 238
Focal length/
28 mm
Distance
(mm)
0.56 m (20 times)
±
 30
1.12 m (40 times)
±
 119
1.68 m (60 times)
±
 267
Focal length/
35 mm
Distance
(mm)
0.7 m (20 times)
±
 33
1.4 m (40 times)
±
 132
2.1 m (60 times)
±
 297
Focal length/
55 mm
Distance
(mm)
1.1 m (20 times)
±
 37
2.2 m (40 times)
±
 148
3.3 m (60 times)
±
 333
  
Table 
4-5-3
<For reference 1: shooting image by AE master lens> (Fig. 4-5-4)
•  Assume it standard image in the setting environment.
•  If the peak of image-formation is to equal distance with AF assist chart position, it is ideal. In actual fact, the image of before and 
behind the peak is displayed. (Because the environment, the individual difference of camera and lens conditions are combined.)
•  The image of before and behind the peak, assume it reference standard image.
•  When shooting the image with sharpness setting of the camera to  +  side, it is easy to distinguish the peak of imaging area remarkably.
Enlargement of same pixel magnification
Example of image shot with 
a certain AE master lens under 
a certain environment.
Identifying the peak position of 
image-formation:
• Center of sharpest area
• Center of area with less color fogged
    - Front defocus area: Magenta fogged
    - Rear defocus area: Green fogged
Example where peak position accidentally matches 
the AF Assist Chart position
 Fig. 
4-5-4
 
4-10
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
<For reference 2: The example of focusing error amount value check> (Fig. 4-5-5)
Check the displacement between the focus position (peak of image-formation) of the lens to be tested and the focus position (peak of im-
age-formation) of the AE master lens.
Example of image shot with lens to be tested (50 mm F1.4)
Example of image shot with AE master lens
Peak area
(existing around 7 to 8 cm
of the rear scale)
Peak area
(existing around 6 to 7 cm
of the front scale)
Error amount = approx. 14 cm
 Fig. 
4-5-5
Example of decision:
The lens to be tested has a tendency of backward defocusing compared to the AE master lens. The error amount is approx. 14 cm.
Compare this error amount with the reference value and check whether the error amount is within the acceptable range. 
If the error amount is outside the acceptable range, perform  4-7-5. 
SB Check/Write .
4-1-2. Adjustment Flow Chart
4-6.  INSTALLATION OF LENS ADJUSTMENT PROGRAM
4-6-1. Installing the Lens Adjustment Program (ActuatorCheckerSAM)
Equipment used
• Personal Computer
•  Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
•  Finished Inspection JIG II (AC 100 - 240 V)
Note 1:
  Personal computer must have the condition that Windows Vista/7 runs normally and USB is connectable.
Note 2:
  Acquire the Lens Adjustment Program (ACSAM-S-VerX.XX.zip) from the each HQ.
1.  Saving Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
1)  Unzip the Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
2) Save ACSAM-S-VerX.XX.exe  in an arbitrary folder.
Note: 
The version of  ACSAM-S-VerX.XX.exe  might be updated.
4-6-2. Connection of Finished Inspection JIG and Startup of Lens Adjustment Program (ActuatorCheck-
erSAM)
Note 1:
 Confirm that 4-6-1. Installing the Lens Adjustment Program (ActuatorCheckerSAM)  has been completed before this procedure is executed.
Note 2:
  In case of performing Finished inspection, be sure to perform in the condition that the lens is laid down (do not perform in the lens standing con-
dition).
Equipment
• Personal Computer
•  Finished Inspection JIG II (AC 100 - 240 V)
Note:
  The cables and so on are not supplied as accessories.
•  AC Cable (Sold on the Market)
•  RS232C Cable (D-Sub 9 Pins (Male with Securing Screws), D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on the 
Market)
•  USB to Serial Cable (D-Sub 9 Pins (Male)) (Sold on the Market)
•  M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG (J-6082-645-A))
•  Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
1. Connection
 
Connect equipment and checking lens as shown in Fig. 4-6-1.
Note: 
ActuatorCheckerSAM  cannot start up without the connection to the finished inspection JIG II.
• Final
 
Finished Inspection JIG II
AC Cable
D-sub 9 Pins: Male
D-sub 9 Pins: Female
RS232C Cable
USB to Serial Cable
Lens
 Fig. 
4-6-1
4-11
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
2.  Startup of Lens Adjustment Program (ActuatorCheckerSAM)
1)  Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSAM-S-VerX.XX.exe  from an arbitrary folder.
Note:
•  At the first time using, the followings appear on the screen (Fig. 4-6-2).
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal 
computer.
Ex.  Com/User Characteristic Number :  iYdDZfq9q
 
Personal Computer : 
SONY PCV-RZ33P
•  It is no need to input password to the computer once registered.
(The screen requires password does not appear.)
•  If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are 
changed. Therefore on the startup, the password input is required again.
3) Input the password and click [OK[Ent]], the following appears on the screen (Fig. 4-6-3).
Fig. 4-6-2
Fig. 4-6-3
4-6-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM)
1. Start 
up ACSAM-S-VerX.XX.exe .
 
 Fig. 
4-6-4
2.  When the Japanese window appears, click the [Setup] button, change the language to English.
Note: 
Depending on the initial startup or setting made at the previous startup, the window differs.
3.  Set the following contents in the SETUP window.
MODEL 
Model to be adjustment in this time
Language English
State Final
Process
Service
 Table 
4-6-1
4.  Confirm that all of the items are set.
 
 Fig. 
4-6-5
5.  Click the [OK] to close the SETUP window.
4-6-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSAM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the in-
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-7. FINISHED ADJUSTMENT/INSPECTION
Equipment (Only the specific equipment is listed.)
•  Adhesive Bond (B-10)
4-7-1. Preparations
1.  Attach the checking lens to the equipment. (Refer to  4-6-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment 
Program (ActuatorCheckerSAM) .)
2.  Start up the lens adjustment program (ActuatorCheckerSAM).
3. Click 
[
Setup
]
 and perform the initial setting. (Refer to  4-6-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM) .)
4-7-2. Finished Inspection Item
1. Adjustment/Inspection Method
1) Click 
[Start[Ent]].
2)  Operate as instructed in the menu.
2. Inspection Item
1) Zoom 
Pattern
2) Adjust 
PI
3) Focus 
Pattern(Motor)
4) Stopping Accuracy
5) Write 
SB
6)   Search Zoom Adj
7)  Search Focus Adj
Note:
  This two items are not adjusted automatically in case of starting Adjustment/
Inspection with clicking [Start[Ent]].
Fig. 4-7-1