DOWNLOAD Sony NEX-3 / NEX-3A / NEX-3D / NEX-3K / NEX-5 / NEX-5A / NEX-5CK / NEX-5D / NEX-5H / NEX-5K (serv.man2) Service Manual ↓ Size: 10.22 MB | Pages: 34 in PDF or view online for FREE

Model
NEX-3 NEX-3A NEX-3D NEX-3K NEX-5 NEX-5A NEX-5CK NEX-5D NEX-5H NEX-5K (serv.man2)
Pages
34
Size
10.22 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
nex-3-nex-3a-nex-3d-nex-3k-nex-5-nex-5a-nex-5ck-ne.pdf
Date

Sony NEX-3 / NEX-3A / NEX-3D / NEX-3K / NEX-5 / NEX-5A / NEX-5CK / NEX-5D / NEX-5H / NEX-5K (serv.man2) Service Manual ▷ View online

NEX-3A/3D/3K/5A/5D/5CD/5K/5CK_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-258 BOARD
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
– ENGLISH –
1-2.  PRECAUTION ON REPLACING THE CABINET FRONT
Perform the following procedures for each of the three washers.
Note: Measure the dimensions before replacement of the Cabinet Front according to procedures (1) to (3).
(1) Remove the Imager Block Assy and the IM Adjust Washers (A, B, C).
(2) Measure the dimensions (A) of the removed IM Adjust Washers.
A
A
+
B
B
(3) Measure the distance (B) between the surface of the screw hole where the IM Adjust Washers were set and the surface of the E-Mount.
(4) Replace Cabinet Front.
(5) Measure the distance after replacement of the Cabinet Front (B) between the surface of the screw hole where the IM Adjust Washers were set and 
the surface of the E-Mount, then compare it with the distance before replacement (B).
 If the distance after replacement (B) is shorter than that before replacement (B)
 
Add IM Adjust Washer with the thickness equal to the difference of dimensions to make the distance (B) equal to that before replacement.
 If the distance after replacement (B) is longer than that before replacement (B)
 
Replace to the IM Adjust Washer with the thickness equal to the difference of dimensions 
 
(distance before replacement (A+B) - distance after replacement (B)).
(6) After assembly, take a test shot to check if there is any blur at circumference of the image.
1-3.  ABOUT THE FLASH EXTENDER (NEX-5H ONLY)
If you attach the flash directly to the camera when using SEL18200 (E 18-200mm F3.5-6.3 OSS), images will be partly shadowed by the lens.
To prevent shadowing, attach the extender.
Extender
A-1787-305-A
Case, EX
4-199-652-01
To attach the extender
(1) Turn the camera off before attaching the extender.
(2) Attach the extender firmly to the camera and tighten the screw.
(3) Attach the flash firmly to the extender and tighten the screw.
Note: Only attach the flash supplied with your camera to the extender.
The changed portions from
Ver.1.2 are shown in blue.
Ver.1.3 2010.09
NEX-3A/3D/3K/5A/5D/5CD/5K/5CK_L2
1-2E
– JAPANESE –
1-1.  SY-258基板交換時の注意
仕向けデータ
補修用基板と交換する時、補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
USBシリアルNo.
セットは、1台毎に異なる固有のID(USB Serial No.)を書き込んだ後、出荷されています。
新品の補修用基板には、このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
1-2.  前キャビネット交換時の注意
以下の手順は3箇所それぞれ行ってください。
注意: 前キャビネットの交換を行う前に、手順(1)から(3)にて交換前の寸法を測定してください。
(1) イメージャ Assy、IM調整ワッシャ (A, B, C)を取り外してください。
(2) 取り外したIM調整ワッシャの寸法(A)を測定してください。
A
A
+
B
B
(3) IM調整ワッシャが取り付いていたビス穴端面からE-Mount端面までの寸法(B)を測定してください。
(4) 前キャビネットを交換してください。
(5) 前キャビネット交換後のIM調整ワッシャが取り付いていたビス穴端面からE-Mount端面までの寸法(B)を測定し、交換前の寸法
(B)と比較してください。
  ・交換前の寸法(B)より交換後の寸法(B)が低かった場合
   
差分寸法分のIM調整ワッシャを追加し交換前の寸法(B)と同じ高さにしてください。
  ・交換前の寸法(B)より交換後の寸法(B)が高かった場合
   
交換前の寸法(A+B) - 交換後の寸法(B)を行い、差分寸法分のIM調整ワッシャへ交換してください。
(6) 組立完成後、試し撮りを行い周辺ボケが無いか確認してください。
1-3.  フラッシュ専用エクステンダーについて(NEX-5Hのみ)
SEL18200(E 18-200mm F3.5-6.3 OSS)を付けてフラッシュ撮影をする場合、本機に直接フラッシュを取り付けるとレンズの影が写っ
てしまうため、エクステンダーを取り付けてからお使いください。
エクステンダー
A-1787-305-A
EXケース
4-199-652-01
取り付け方
(1) 本機の電源を「OFF」にしてください。
(2)エクステンダーを本機に最後まで差し込んでからネジを締め、しっかり固定してください。
(3)フラッシュをエクステンダーに最後まで差し込んでからネジを締め、しっかり固定してください。
注意: エクステンダーには本体付属のフラッシュ以外は取り付けないでください。
The changed portions from
Ver.1.2 are shown in blue.
Ver.1.3 2010.09
NEX-3A/3D/3K/5A/5D/5CD/5K/5CK/5H_L2
2-1
2. REPAIR  PARTS  LIST
Follow the disassembly in the given numerical order.
(NEX-5A/5D
/
5CD
/5K/5CK/
5H
)
IDENTIFYING  PARTS
Link
ACCESSORIES
View Position
ASSEMBLY
•  Abbreviation
  AUS  : Australian model
  CH  : Chinese model
  CND  : Canadian model
  J 
: Japanese model
  JE 
: Tourist model
  KR  : Korea model
(ENGLISH)
NOTE:
•  -XX, -X mean standardized parts, so they may have some differences from the original one.
•  Items marked “*” are not stocked since they are seldom required for routine service. Some delay
should be anticipated when ordering these items.
•  The mechanical parts with no reference number in the exploded views are not supplied.
•  Due to standardization, replacements in the parts list may be different from the parts specified
in the diagrams or the components used on the set.
(JAPANESE)
【使用上の注意】 
•  -XX, -Xは標準化部品のため, セットに付いている部品と異なる場合があります。
•  *印の部品は常備在庫しておりません。
•  ここに記載されている部品は,  補修用部品であるため,  回路図及びセットに付いている部品と
異なる場合があります。
図面番号で部品を指定するときは基板名
又はブロックを併せて指定してください。
お願い
•  Color Indication of Appearance Parts
  Example:
  (SILVER) : Cabinet’s Color
  (Silver)  : Parts Color
•  外装部品色表示
  例:
  (SILVER) :セットの色を表す。
  (Silver)  :部品の色を表す。
The  components  identified  by  mark  0  or
dotted line with mark 0 are critical for safety.
Replace only with part number specified.
Les composants identifiés par une marque
0
sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant
le numéro spécifié.
0
印の部品,または0印付の点線で囲ま
れた部品は,安全性を維持するために,
重要な部品です。
従って交換時は,必ず指定の部品を使用
してください。
When indicating parts by reference number,
please include the board name.
Bottom View
Top View
Back View
Right View
Left View
Front View
THE COMBINATION OF CABINET’S COLOR AND SCREW 
(NEX-5A/5D/
5CD
/5K/5CK/
5H
)
The screw pointed   is different according to the cabinet's color.
For the combination of cabinet's color and screw, please refer to Table 
2-1.
 
Table 2-1
Screw's
Ref. No. (Parts Color.)
Cabinet's Color
#201 (Silver), #202 (Silver)  SILVER, 
GOLD
#196 (Black), #200 (Black)
BLACK
9�
Tripod Screw
qs�
Cabinet Front Assy
[Disassembly]
[Exploded View]
• Cabinet Front Section-1
• Cabinet Front Section-2
6�
BT Holder Block Assy
• BT-060 Flexible Board
• FP-1236 Flexible Board
• CN-439 Complete Board
qa�
MB Driving Unit
0�
Imager Block Assy
[Disassembly]
[Exploded View]
• IS-075 Flexible Board
• IS-076 Flexible Board
5�
Jack Cover Base Assy
1�
Cabinet (Rear) Block Assy
4
SY-258 Complete Board
2
Control Switch Block
3�
Main Frame Block Assy
[Disassembly]
[Exploded View]
• FP-1237 Flexible Complete Board
7�
RL Button Block Assy
8�
RL Block Assy
• RL-101 Flexible Board
The changed portions from
Ver.1.4 are shown in blue.
Ver.1.5 2011.01
NEX-3A/3D/3K/5A/5D/5CD/5K/5CK/5H_L2
2-2
– ENGLISH –
– JAPANESE –
NOTE  FOR  REPAIR
修理時の注意
•  Make sure that the flat cable and flexible board are not cracked or
bent at the terminal.
 Do not insert the cable insufficiently nor crookedly.
•  When remove a connector, do not pull at wire of connector. It is
possible that a wire is snapped.
•  When installing a connector, do not press down at wire of connector.
 It is possible that a wire is snapped.
•  Do not apply excessive load to the gilded flexible board.
•  フラットケーブルおよびフレキシブル基板の端子面に欠け,折
れ等がないことを確認する。
  また,コネクタへの接続は,差し込み不足や斜め差しにならな
いように注意する。
•  コネクタを取り外す時に,線材部(極細)を持って引っ張ると断
線する恐れがありますので,絶対に線材部(極細)を持って引っ
張らないでください。
•  線材部(極細)を押さえながらコネクタを差し込むと,線材部(極
細)が断線する恐れがありますので,絶対に線材部(極細)には負
担をかけないでください。
•  金メッキされているフレキシブル基板には,強い負担をかけな
いでください。
Cut and remove the part of gilt
which comes off at the point.
(Be careful that some
pieces of gilt may be left inside)
先端の剥がれたメッキ部はカットして
除去してください。
(メッキ破片がコネクタ内に残っている
場合もあるので注意してください)
Page of 34
Display