Sony ILCE-QX1 / ILCE-QX1L Service Manual ▷ View online
ILCE-QX1/QX1L
1-9
1-2. FUSE
Ref. No.
Part No.
Description
F0001 1-576-850-31 FUSE
(3.15A/24V)
F0002
1-576-850-31
FUSE (3.15A/24V)
F0004
1-576-760-31
FUSE (1.6A/32V)
F0005
1-576-760-31
FUSE (1.6A/32V)
F0600
1-576-415-31
FUSE (2A/32V)
Primary side
F0600
5.0V
F0001
F0002
F0004
F0005
4.2 ~ 8.4V
4.2 ~ 8.4V
SY-1047 BOARD
(SIDE A)
(SIDE A)
SY-1047 BOARD (SIDE B)
ILCE-QX1/QX1L
1-10
1-3. ACCESSORIES
901
902
903
904
905
906
Ref. No. Part No.
Description
901
1-846-615-12
Micro USB cable
902
4-544-742-01 Wrist
strap
903
X-2588-134-2 Smartphone
attachment
904
4-188-536-01
Body cap (ILCE-QX1)
905
4-170-837-01
Rear lens cap (ILCE-QX1L)
* 906
4-546-410-01
Reference Guide (JAPANESE)
* 906
4-546-410-11
Reference Guide (ENGLISH, FRENCH, SPANISH)
* 906
4-546-410-21
Reference Guide (SIMPLIFIED CHINESE)
* 906
4-546-411-11
Reference Guide (ENGLISH, FRENCH, GERMAN,
SPANISH, DUTCH, SWEDISH, ITALIAN,
PORTUGUESE, RUSSIAN, ARABIC,
SPANISH, DUTCH, SWEDISH, ITALIAN,
PORTUGUESE, RUSSIAN, ARABIC,
TRADITIONAL CHINESE, KOREAN)
Ref. No. Part No.
Description
8-328-301-00
Rechargeable battery pack NP-FW50/J (J)
8-328-301-31
Rechargeable battery pack NP-FW50/UC (US, CND)
8-328-301-51
Rechargeable battery pack NP-FW50/CE (EXCEPT US, CND, CH, J)
8-328-301-72
Rechargeable battery pack NP-FW50/CN (CH)
ILCE-QX1/QX1L
2-1
2. TROUBLE SHOOTING
2-1. SELF-DIAGNOSIS FUNCTION
Power lamp
Access lamp
LCD
Status
Battery capacity
indicator
No memory card
indicator
─
─
─
─
Power off
Green
─
Lit
─
Power on (Normal)
Green
─
Lit
Lit
No memory card
Green
Red
Lit
─
Accessing to memory card
Red
Red
Lit
─
Recording a movie
Green
─
─
─
Receiving power
Orange
─
─
─
Charging
Red (flashing: 2Hz)
─
Lit
Lit
Memory card full capacity
Red (flashing: 2Hz)
─
─
Flashing (2Hz)
Memory card error
(Turn the power off and on again, or taking out and
inserting the memory card.)
(Turn the power off and on again, or taking out and
inserting the memory card.)
Green
Red
─
Flashing (1Hz)
Recovering
Red (flashing: 2Hz)
─
Flashing
─
Battery error
(Turn the power off and on again.)
(Turn the power off and on again.)
Green (flashing)
─
Flashing (Empty)
─
Battery is empty
Red (flashing: 2Hz)
─
Lit
─
Fatal error
(Turn the power off and on again.)
(Turn the power off and on again.)
Red (flashing: 1Hz)
─
Lit
─
PMCA (Play Memories Camera Apps) is being
restored
restored
ILCE-QX1/QX1L
3-1
3. SERVICE NOTE
3-1. PRECAUTION ON REPLACING THE SY-1047 BOARD
The board for repair is not recorded the information peculiar to a model. Therefore the following data are needed to record.
Note: The “LOAD AND WRITE” function of “ADJUSTMENT DATA BACKUP” in the DATA tab of Adjust manual performs overwrite by all data of the
set. Therefore the LOAD AND WRITE performs before carrying out following operation.
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID &
USB SERIAL No. INPUT” and enter these IDs.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID &
USB SERIAL No. INPUT” and enter these IDs.
Note: A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a differ-
ence from the ID registered by the customer.
Update of MAC Address
When replacing the SY board, the CPU’s unique number (MAC address) must be reloaded. Perform the following procedure to reload the
CPU’s unique number (MAC address).
1. Download the latest-version Adjust manual.
2. Install the downloaded Adjust manual.
3. Execute “Wireless LAN Setting (MAC Address)” on the ADJUST tab.
CPU’s unique number (MAC address).
1. Download the latest-version Adjust manual.
2. Install the downloaded Adjust manual.
3. Execute “Wireless LAN Setting (MAC Address)” on the ADJUST tab.
Password required for Wi-Fi connection
A password required for Wi-Fi connection is recorded in every SY board. A label to present the password to the customer is stuck to every SY
board for service. When the SY board is replaced, attach this label to the unit to be sent back.
board for service. When the SY board is replaced, attach this label to the unit to be sent back.
Note 1: The new SSID and password can be checked on the PC connected to the unit with a USB cable.
[Computer]
→ [PMHOME] → [INFO] → [WIFI_INF.TXT]
Note 2: When succeeding the data from the board before replacing to new board for repair by using The “LOAD AND WRITE” function of “ADJUST-
MENT DATA BACKUP” in the DATA tab of Adjust manual, perform following operations. The seal that is attached former board for repair is not
needed.
needed.
1. Reset the unit.
2. Download the WIFI_INF_CREATE.zip and generate “WIFI_INF.txt” file to the PMHOME folder of the unit by using the tool.
2. Download the WIFI_INF_CREATE.zip and generate “WIFI_INF.txt” file to the PMHOME folder of the unit by using the tool.
– ENGLISH –
Click on the first or last page to see other ILCE-QX1 / ILCE-QX1L service manuals if exist.