1-7
1-10.   THREE TUBE LUBRICATING BLOCK ASSY AND GROUP 1 FRAME REPLACING METHOD
Claws
Sensors
FG Leaf
Spring
Claw
FPC Retainer
4. Disconnect the Flexible Board from the Connector on the LF-139 Flexible Board.
6. Disconnect the Flexible Board from the Connector on the LF-139 Flexible Board.
5. Peel off the FPC Tape.
Flexible Board
Flexible Board
FPC Tape
Connector
Connector
Ribs
Rib
Rib
Rib
Boss
Boss
Boss
Boss
LF-139 Flexible Board
Z Retainer
Screws
Screw
Sensor
7. Remove the LF-139 Flexible Board.
8. Remove the four screws and remove the Z Retainer and the Sensor.
Removal
1. Disengage the two claws and remove the FG Leaf Spring.
2. Remove the two Sensors.
3. Disengage the claw and remove the FPC Retainer.
A
A
Flexible Board
Flexible Board
Main Body
Main Body
Rotary Cam Tube
Rotary Tube
Stationary Tube Assy
Gear A
Gear A
Gear B
Gear Worm
Wheel
Rear Mirror
Plate
9. Detach the Rear Mirror Plate and remove the Gear Worm Wheel, Gear A, and Gear B.
10. Turn the Gear in the arrow direction to extend the Mirror Plate slightly.
11. Turn portion A in the arrow direction to TELE end and remove the Flexible Board from the hole in the Stationary Tube Assy.
12. Turn portion A in the arrow direction to WIDE end and detach the Main Body from the Stationary Tube Assy.
13. Remove the Main Body in the arrow direction.
14. 
Remove the Rotary Cam Tube from the Rotary Tube in the arrow direction.
DSC-WX150_L2
1-8
Lens Block
1 Frame Assy
Cam Tube A
3 Group Assy
Tweezers
Claw
Claw
15. Turn the 3 Group Assy approx. 20°  in the arrow direction.
16. Disengage the three Claws with tweezers.
17. Remove the Lens Block.
18. Remove the 1 Frame Assy from the Cam Tube A.
Cam Tube B
Cam Tube B
2 Group Frame
3 Group Assy
Straight Tube Block
Straight Tube
Straight Tube
19. Fully turn the Cam Tube B in the arrow direction.
20. Remove the 2 Group Frame.
21. Remove the Straight Tube Block.
22. Turn the Straight Tube in the arrow direction to detach it from the Cam Tube B.
DSC-WX150_L2
1-9
White Part
Thinnest Groove
Cam Tube B
Cam Tube B
Lever
Cutout
Straight Tube
Straight Tube
3 Group Assy
Straight Tube Block
2 Group Frame
2 Group Frame
Shaft of 3 Group Assy
Top side view
Installation
1. Align the Lever with the cutout as shown in the figure, and then install the Straight Tube to the Cam Tube B.
    Note: Be sure to set the Straight Tube at the correct insertion position.
2. Turn the Straight Tube in the arrow direction to the maximum.
3. Install the Straight Tube Block aligning the thinnest groove with the white part as shown in the figure, and then turn 
    the Cam Tube B in the arrow direction to the maximum.
4. Install the 2 Group Frame at a position where the Shaft of 3 Group Assy is visible through the cutout of the 2 Group Frame.
3 Group Assy
Lever
Lever
1 Frame Assy
Cabinet Number
Flexible Board
Claws
Main Body
Claws
Cam Tube A
Rotary Cam Tube
Semicircular 
Cutout
Gear Edge
Rotary Tube
Stationary Tube Assy
8. Install the Rotary Cam Tube to the Rotary Tube aligning the semicircular cutout with the Gear edge.
9. Install the Stationary Tube Assy at the position shown in the figure as a guideline.
    Note: Be sure to install the Rotary Cam Tube with the semicircular cutout and the Gear edge set in the "OK" state shown in the figure.
10. Install the Main Body so that the Flexible Board position matches the hole to pass the Flexible Board.
5. Install the 1 Frame Assy so the Lever positions match.
    Note: Confirm that the Barrier closes when the 1 Frame Assy is pushed.
6. Set the 3 Group Assy in the groove in the orientation where the Flexible Board comes to the nearly opposite side of the cabinet number 
    on the Cam Tube A.
    Note: Be sure to set the 3 Group Assy at the correct insertion position.
7. Push the 3 Group Assy until the three claws lock.
OK
NG
DSC-WX150_L2
1-10
Fold inside
Draw up
Gear A
Gear A
Gear B
Gear Worm
Wheel
Rear Mirror
Plate
Z Retainer
Screws
Screw
Flexible Board
Sensor
LF-139 Flexible Board
Ribs
Rib
Rib
Rib
Boss
Boss
Boss
Boss
11. Turn the Gear in the arrow direction to extend the Mirror Plate slightly.
12. Turn portion A in the arrow direction to TELE end and remove the Flexible Board from the hole in the Stationary Tube Assy.
13. Install the Gear Worm Wheel, Gear A, and Gear B.
14. Install the Rear Mirror Plate.
15. Install four screws and the Z Retainer. Tighten the screws in the order of numbers in the figure below.
16. Install the LF-139 Flexible Board.
1
2
3
4
Connector
Flexible Board
Claws
Sensors
OK
NG
FG Leaf
Spring
FG Leaf Spring
FG Leaf Spring
Claw
FPC Retainer
Flexible Board
FPC Tape
FPC Tape
Rib
Connector
17. Connect the two Flexible Boards to the Connectors on the LF-139 Flexible Board.
18. Stick the FPC Tape as shown in the figure below.
19. Install the two Sensors and attach the FG Leaf Spring.
      Note: Attach the FG Leaf Spring in the correct orientation.
20. Attach the FPC Retainer.
21. Apply a voltage of 2.5 V to the DC Motor and retract the Lens.
DC2.5V
Page of 21
Display