DOWNLOAD Sony DSC-W90 (serv.man15) Service Manual ↓ Size: 990.05 KB | Pages: 42 in PDF or view online for FREE

Model
DSC-W90 (serv.man15)
Pages
42
Size
990.05 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS BRAZIL
File
dsc-w90-sm15.pdf
Date

Sony DSC-W90 (serv.man15) Service Manual ▷ View online

6-28
DSC-W90_ADJ
SY-169 BOARD (SIDE A)
1
2
3
4
1
2
3
4
SE501
SE502
PP
YY
YY:YAW sensor sensitivity    
t
 S
501
PP:PITCH sensor sensitivity 
t
 S
502
8.
CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
8-1. Precaution before adjustment
Before adjustment, read the following data and record them.
When the SY-169 board is replaced, read out the data before the
replacement, and record them.
Reading out method:
1) Read out the data in Block:11, Page:61, Address:0E10, and
name this as Dp.
2) Read out the data in Block:11, Page:61, Address:0E11, and
name this as Dy.
8-2.
Preparation when the angular velocity
sensor or the SY-169 board is replaced
Note down the sensitivity displayed on the angular velocity sensor of
the repair parts. At this time, note down also to which board it was
attached to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0E10, 0E11
Note 1:
The sensor sensitivity of SE501 and SE502 of the SY-
169 board is written only repair parts.
Preparation:
1) Read the PITCH sensor (SY-169 board SE502) sensitivity writ-
ten on repair parts, and named this as S
502
.
2) Read the YAW sensor (SY-169 board SE501) sensitivity writ-
ten on repair parts, and named this as S
501
.
Fig. 6-1-25
How to read the sensitivity data of angular velocity sen-
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
Fig. 6-1-26
6 0
Hand Writing
1
2
4
3
For the sensor sensitivity value 60
Description example :
6-29
DSC-W90_ADJ
8-4.
Angular Velocity Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at the lower left of the screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
8-3. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0E10, 0E11
Note 1:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-27
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
X.XX / X.XX
6-30
DSC-W90_ADJ
1-7-2.
Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
Table 6-1-5. The Automatic Adjustment Program executes the ad-
justment items if the LCD Adjustment Start button is clicked.
Button
Adjustment
Adjusting  Address
Name
Signal
Page
Address
LCD
V-COM Adj.
11
60
0301
Adjustment White Balance Adj.
11
60
0368, 0369
Table 6-1-5
1-7. AJUSTES DE SISTEMA DO LCD
1-7-1.
Function of Each Button on LCD System
Adjustment Screen
Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu
screen, and the “LCD SYSTEM ADJUSTMENT” screen in Fig.
6-1-28 will appear.
Fig. 6-1-28
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
“LCD Adjustment” starts.
3
[Reboot] button
When this button is clicked, the camera is rebooted.
3
2
1
6-31
DSC-W90_ADJ
1-7-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. V-COM Adj.
3. White Balance Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj.”.
3) Upon successful completion of the “1. Data Setting during LCD
Adj.”, the following screen is displayed during the execution
of “2. V-COM Adj.”. Using the [Up]  /  [Down]  button on the
screen, adjust so that the brightness of portions A and B on the
LCD panel is equal. After the adjustment, click the [End] but-
ton in the screen.
4) If the [End] button is clicked, the following screen is displayed
during the execution of “3. White Balance Adj.”. Check that
the LCD screen is not colored. If colored, using the [Up]  /
[Down] button on the screen, adjust so that the LCD screen is
not colored. After the adjustment, click the [End] button in the
screen.
5) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.