DOWNLOAD Sony DSC-W90 (serv.man15) Service Manual ↓ Size: 990.05 KB | Pages: 42 in PDF or view online for FREE

Model
DSC-W90 (serv.man15)
Pages
42
Size
990.05 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS BRAZIL
File
dsc-w90-sm15.pdf
Date

Sony DSC-W90 (serv.man15) Service Manual ▷ View online

6-20
DSC-W90_ADJ
1-6. AJUSTES DE SISTEMA DA CÂMERA
1-6-1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-18 will appear.
Fig. 6-1-18
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 7” starts.
4
[Reboot] button
When this button is clicked, the camera is rebooted.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment 1-6. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
5
4
3
2
1
2
3
6-21
DSC-W90_ADJ
1-6-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program divides the ad-
justment items into seven, camera adjustment 1-6. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note 1:
Dark Siemens star chart.
Table 6-1-4
Block
Page
Address
Auto Orientation Adj.
11
61
0E0A to 0E0D
CAMERA Adjustment 2
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note 1) or
Flange back adjustment jig
11
61
0F1C, 0F1D,
0F20 to 0F3F,
CAMERA Adjustment 3
Flange Back Check
Siemens star
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
-
-
-
F No. Compensation
11
61
095A
Measure Gain Adj.
11
61
0964
Light Value Adj.
11
61
0961
Mechanical Shutter Adj.
11
61
0980, 0981,
0998, 0999
AWB 3200K-5800K
Standard Data Input
11
61
0C00 to 0C21,
0C24 to 0C49
AWB 3200K-5800K Check
-
-
-
Color Reproduction
Adj. & Check
11
61
0C50 to 0C57
CCD Linearity Check
-
-
-
CCD White Defect
Compensation Check
11
61
0200 to 02FF,
0300 to 03FF,
0400 to 04FF,
0500 to 05FF
CCD Black Defect
Compensation Check
11
61
0000 to 00FF,
0100 to 01FF,
0400 to 04FF,
0500 to 05FF
CAMERA Adjustment 5
Strobe Adj.
Flash adjustment box (50 cm)
11
61
09C2, 09C3,
0C72 to 0C75
CAMERA Adjustment 6
Auto Focus Illumination Check
Flash adjustment box (50 cm)
11
61
0F10 to 0F15
CAMERA Adjustment 7
Angular Velocity Sensor
Sensitivity Adj.
Not required
11
61
0E10, 0E11
Adjusting Address
Clear chart
(Standard picture frame)
Button Name
Adjustment
Subject
9 color chart
(Standard picture frame)
CAMERA Adjustment 1
CAMERA Adjustment 4
Clear chart
(Standard picture frame)
Hall Adj.
0E00 to 0E04,
0E08, 0E09,
0E20 to 0E2F
11
61
Not required
6-22
DSC-W90_ADJ
1-6-3.
Adjusting Method
1.
CAMERA Adjustment 1
Note:
There is no magnetic substance within around 8 cm of the
camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Hall Adj.
3. Auto Orientation Adj.
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, the following message and screen are displayed. Set
the camera in accordance with the message.
4) If the [OK] button is clicked, “2. Hall Adj.” will be executed.
5) Upon successful completion of “2. Hall Adj.”, the following
message and screen are displayed. Set the camera in accor-
dance with the message.
Processing after Completing Adjustment:
[Checking method]
1) [HOME screen] 
t  [Settings]  t  [Shooting Settings] t
[Shooting Settings 2] 
t Select [Auto Orientation] to “ON”.
2) Shoot with the set in respective positions (a) to (c) shown be-
low.
3) Check the pictures in the Playback mode to confirm that the
pictures are rotated correctly.
(a)
(b)
(c)
Fig. 6-1-19
6) If the [OK] button is clicked, “3. Auto Orientation Adj.” and
“4. Release of Data Setting during Camera Adj.” will be ex-
ecuted.
7) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
6-23
DSC-W90_ADJ
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
Note 2:
When using the flange back adjustment jig, take care of
the following points:
For the illumination, use a light source such as an in-
candescent lamp or inverter type fluorescent light free
from flickering.
Do not make an adjustment in the environment where
fluorescent lamp flickering occurs even if the illumi-
nance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent
light at a place free from the influence of room illumi-
nation.
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-21
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following
figure.
Note 1:
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-20
Page of 42
Display

Click on the first or last page to see other DSC-W90 (serv.man15) service manuals if exist.