DOWNLOAD Sony DSC-W110 / DSC-W115 (serv.man3) Service Manual ↓ Size: 593.67 KB | Pages: 35 in PDF or view online for FREE

Model
DSC-W110 DSC-W115 (serv.man3)
Pages
35
Size
593.67 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-w110-dsc-w115-sm3.pdf
Date

Sony DSC-W110 / DSC-W115 (serv.man3) Service Manual ▷ View online

6-16
DSC-W110/W115_ADJ
1-6.
CAMERA  SYSTEM  ADJUSTMENTS
1-6-1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-13 will appear.
Fig. 6-1-13
1
[To Menu] button
Return to the main menu.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 6” starts.
4
[Reboot] button
When this button is clicked, the camera is rebooted.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
5
4
3
2
1
2
3
6-17
DSC-W110/W115_ADJ
1-6-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program divides the ad-
justment items into six, camera adjustment 1-6. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note:
Dark Siemens star chart.
Table 6-1-4
Block
Page
Address
CAMERA Adjustment 1
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note) or
Flange back adjustment jig
11
61
0F1C, 0F1D,
0F20 to 0F3F
CAMERA Adjustment 2
Flange Back Check
Siemens star
(1.0m from front the lens)
(Illuminance: 200 to 400 lux)
-
-
-
F No. Compensation
11
61
095A to 095F
Measure Gain, LV Adj.
11
61
0961 to 0968
Mechanical Shutter Adj.
11
61
0980 to 09AD
AWB 3200K-5800K
Standard Data Input
11
61
0C00 to 0C21,
0C24 to 0C49
AWB 3200K-5800K Check
-
-
-
Color Reproduction Check
-
-
-
CCD White Defect
Compensation Check
11
61
0200 to 03FF
CCD Black Defect
Compensation Check
11
61
0000 to 01FF
CAMERA Adjustment 5
Strobe check
Flash adjustment box (50 cm)
-
-
-
CAMERA Adjustment 6
Auto Focus Illumination Check
Flash adjustment box (50 cm)
11
61
0F10 to 0F15
CAMERA Adjustment 3
Clear chart
(Standard picture frame)
CAMERA Adjustment 4
9 colors chart
(Standard picture frame)
Clear chart
(Standard picture frame)
Adjusting Address
Button Name
Adjustment
Subject
6-18
DSC-W110/W115_ADJ
1-6-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following
figure.
Note 1:
The attachment lenses are not used.
Note 2:
Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the
minipattern box.
Fig. 6-1-14
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Illuminance: about 300 lux)
Note 3:
When using the flange back adjustment jig, take care of
the following points:
• For the illumination, use a light source such as an in-
candescent lamp or inverter type fluorescent light free
from flickering.
• Do not make an adjustment in the environment where
fluorescent lamp flickering occurs even if the illumi-
nance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent
light at a place free from the influence of room illumi-
nation.
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
Note 4:
Take care not to hit the flange back adjustment jig
when extending the lens.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-15
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
6-19
DSC-W110/W115_ADJ
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) Click the [OK] button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK] button.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation of Flange Back Adj.”.
4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
Page of 35
Display