Sony DSC-T9 (serv.man4) Service Manual ▷ View online

6-31
DSC-T9_ADJ
1-7.
INITIALIZATION  OF  DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0C”.
4) Click  [All]  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-65 A)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Select page: 8E, address: 00 and set data: 20.
10) Change the data shown in the “3. 2F Page Modification Data”
and “4. BF Page Modification Data” by manual input.
11) Click [Save] on the SEUS screen.
12) Select page: 80, address: 34, and check that the data is “00”.
13) Select page: 80, address: 30, and check that the data is “00”.
14) Perform “VIDEO OUT Default Data Check” and “Initial Lan-
guage Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
Fig. 6-1-65
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6E or 6F or 78 or CE page data have been initial-
ized, the following adjustment needs to be performed
again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Sector Write] on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0C”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-65
B
)
5) Click [Write] to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click [Close] to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
10) When 2F page is initialized, Change the data shown in the “3.
2F Page Modification Data” by manual input.
11) When BF page is initialized, Change the data shown in the “4.
BF Page Modification Data” by manual input.
12) Click [Save] on the SEUS screen.
13) Select page: 80, address: 34, and check that the data is “00”.
14) Select page: 80, address: 30, and check that the data is “00”.
15) When 4F page is initialized, perform “VIDEO OUT Default
Data Check” and “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 [Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click [Connect]
on the SEUS screen to restore the “connected” state. (In
case that the power does not turn on again, press the power
button.)
B
A
0C
6-32
DSC-T9_ADJ
3.
2F Page Modification Data
Order Page Address
Data
Procedure
1
2F
4E
4F
Set the data.
2
2F
50
49
Set the data.
3
2F
92
1B
Set the data.
4
2F
93
1A
Set the data.
5
2F
94
30
Set the data.
6
2F
98
37
Set the data.
7
2F
A2
1B
Set the data.
8
2F
A3
1A
Set the data.
9
2F
A4
30
Set the data.
10
2F
A8
35
Set the data.
11
2F
D0
27
Set the data.
12
2F
D2
1B
Set the data.
13
2F
D3
1A
Set the data.
14
2F
D4
30
Set the data.
15
2F
D8
35
Set the data.
4.
BF Page Modification Data
Order Page Address
Data
Procedure
1
BF
81
4E
Set the data.
2
BF
85
61
Set the data.
3
BF
89
4E
Set the data.
4
BF
8D
4E
Set the data.
6-33
DSC-T9_ADJ
6-2. SERVICE  MODE
1.
Setting the Test Mode
Page 40
Address A1,  A3
• Forced CAMERA (Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
• Forced CAMERA (Program Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 02.
• Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
3) Select page: 40, address: A3, and set data: 07.
• Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
• After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-34
DSC-T9_ADJ
Hexadecimal-decimal Conversion Table
Lower digit of
hexadecimal 
Upper digit 
of hexadecimal
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
77
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
174
159
175
160
161
162
163
164
165
166
167
168
169
170
171
172
173
177
176
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
1
(Example)
If the displayed data is “BD”;
Because the upper digit of the adjustment number is B, and the lower digit is D, the meeting point 
“189” of 1 and 2 in the above table is the corresponding decimal number.
0
2
3.
Data Process
The calculation of the SEUS display data (hexadecimal notation)
are required for obtaining the adjustment data of some adjustment
items. In this case, after converting the hexadecimal notation to
decimal notation, calculate and convert the result to hexadecimal
notation, and use it as the adjustment data. Indicates the hexadeci-
mal-decimal conversion table.
Table 6-2-1
Page of 39
Display

Click on the first or last page to see other DSC-T9 (serv.man4) service manuals if exist.