DOWNLOAD Sony DSC-T9 (serv.man4) Service Manual ↓ Size: 553.55 KB | Pages: 39 in PDF or view online for FREE

Model
DSC-T9 (serv.man4)
Pages
39
Size
553.55 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-t9-sm4.pdf
Date

Sony DSC-T9 (serv.man4) Service Manual ▷ View online

6-23
DSC-T9_ADJ
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-41
5) Upon successful completion of “3. Color Reproduction Adj.
& Check”, the following message is displayed. Change the
chart in accordance with the message.
Fig. 6-1-42
6) Click the [OK] button, and the items from “4. CCD Linearity
Check” to “7. Release of Data Setting during Camera Adj.”
will be executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK] button.
Fig. 6-1-43
8.
CAMERA Adjustment 5
Note:
After executing the “AWB 3200-5800K Standard Data In-
put” perform the “CAMERA Adjustment 5” successively
without turning off the power switch of the camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. Color Reproduction Adj. & Check
4. CCD Linearity Check
5. CCD White Defect Compensation Check
6. CCD Black Defect Compensation Check
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-28 to
Fig. 6-1-30 (See page 6-20), set the subject and click the [OK]
button.
Fig. 6-1-39
4) After that, “3. Color Reproduction Adj. & Check” will be ex-
ecuted. Upon completion of adjustment, the check result is
displayed on the Color Reproduction Check screen.
Fig. 6-1-40
6-24
DSC-T9_ADJ
9.
CAMERA Adjustment 6
Note:
“CAMERA Adjustment 6” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “3. Preparing the Flash
Adjustment Box” (see page 6-9).)
Fig. 6-1-44
4) Press the [OK] button, and the “2. Strobe Adj.” will be executed.
5) During execution of “2. Strobe Adj.”, the following message
is displayed. After checking the flashing of strobe light, click
the  [OK]  button. (This message is displayed 2 times during
execution of adjustment.)
Fig. 6-1-45
6) Upon successful completion of “2. Strobe Adj.”, “3.Release
of Data Setting during CAMERA Adj.” is executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK] button.
Fig. 6-1-46
10. CAMERA Adjustment 7
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Auto Focus Illumination Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 7.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “3. Preparing the Flash
Adjustment Box” (see page 6-9).)
Fig. 6-1-47
4) Press the [OK]  button, and the “2. Auto Focus Illumination
check” will be executed.
5) Upon successful completion of the “2. Auto Focus Illumina-
tion Check”, the “3. Release of Data Setting during Camera
Adj.” will be executed successively.
6) Upon successful completion of all items of the CAMERA
Adjustment 7, the following message is displayed. Click the
[OK] button.
Fig. 6-1-48
6-25
DSC-T9_ADJ
11. Angular Velocity Sensor Sensitivity Adjustment
Perform this adjustment only when replacing the angular velocity
sensor or lens block. When the microprocessor, circuit etc. is dam-
aged, don't perform this adjustment but check the operations only.
11-1. Adjusting method when the angular velocity
sensor or the SY-141 board is replaced
Note down the sensitivity displayed on the angular velocity sensor of
the repair parts. At this time, note down also to which board it was
attached to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Page
CF
Adjustment Address
0C, 0D
Note 1:
The sensor sensitivity of SE501 and SE502 of the SY-
141 board is written only repair parts.
Preparation:
1) Read the PITCH sensor (SY-141 board SE502) sensitivity writ-
ten on repair parts, and named this as S
502
.
2) Read the YAW sensor (SY-141 board SE501) sensitivity writ-
ten on repair parts, and named this as S
501
.
Fig. 6-1-49
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
Calculate D
0C
’ and D
0D
using the following equation
(decimal calculation). (Note2)
D
0C
’= (60/S
502
× 134
D
0D
’= (60/S
501
× 134
4
Convert D
0C
’ and D
0D
’ to
hexadecimal notation, and
obtain D
0C
 and D
0D
. (Round
off to one decimal place)
5
CF
0C
D
0C
Set the data.
6
CF
0D
D
0D
Set the data.
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
Note 2:
S
501
 and S
502
 are the data read in the “Preparation”.
Note 3:
Refer to “Table 6-2-1. Hexadecimal-decimal Conversion
Table”.
Processing after Completing Initializing:
Order Page Address
Data
Procedure
1
00
01
00
Set the data.
2
Check that the steady
shot operations have
been performed normally.
SE501
SE502
SY-141 BOARD (SIDE B)
XX
XX
YAW sensor sensitivity    
t
 S
501
PITCH sensor sensitivity 
t
 S
502
6-26
DSC-T9_ADJ
11-2. Adjusting method when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Page
CF
Adjustment Address
0C, 0D
Note 1:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-50
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
Calculate D
0C
’ and D
0D
using the following equation
(decimal calculation). (Note2)
D
0C
’= (1.00/L
1
× 134
D
0D
’= (1.00/L
2
× 134
4
Convert D
0C
’ and D
0D
’ to
hexadecimal notation, and
obtain D
0C
 and D
0D
. (Round
off to one decimal place)
5
CF
0C
D
0C
Set the data.
6
CF
0D
D
0D
Set the data.
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
Note 2:
L
1
 and L
2
 are the data read in the “Preparation”.
Note 3:
Refer to “Table 6-2-1. Hexadecimal-decimal Conversion
Table”.
Processing after Completing Initializing:
Order Page Address
Data
Procedure
1
00
01
00
Set the data.
2
Check that the steady
shot operations have
been performed normally.
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
X.XX / X.XX
Page of 39
Display