DOWNLOAD Sony DSC-P7 (serv.man4) Service Manual ↓ Size: 477.34 KB | Pages: 45 in PDF or view online for FREE

Model
DSC-P7 (serv.man4)
Pages
45
Size
477.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p7-sm4.pdf
Date

Sony DSC-P7 (serv.man4) Service Manual ▷ View online

DSC-P7
6-7
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2)
530 mm
(400 mm)
woody board B (2)
500 mm
(370 mm)
woody board C (1)
1000 mm
(700 mm)
1026 mm: Depth 1 m
(513 mm: Depth 50 cm)
1026 mm: Depth 1 m
(513 mm: Depth 50 cm)
1000 mm
(700 mm)
1000 mm
(700 mm)
1030 mm
(730 mm)
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig 6-1-10)
Fig. 6-1-9
woody board A
woody board B
woody board B
woody board C
woody board A
Fig. 6-1-10
DSC-P7
6-8
1-2.
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE
DATA
1-2-1.
Initialization of A, D Page Data
1.
Initializing A, D Page Data
Note:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Video system adjustments
3) LCD system adjustments
Adjsuting page
A
Adjsuting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 73
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
0E
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of
A, D page Data”.
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of A, D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
A Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
Address
Initial value
Remark
00, 01
Fixed data-1 (Initialized data)
02
00
Test mode
03 to 81
Fixed data-1 (Initialized data)
82
6A
VCO adj. (NTSC Mode)
83
7C
VCO adj. (PAL Mode)
84
20
V-COM adj.
85
BC
Bright adj.
86
08
Black limit adj.
87
BF
Psig Gray adj.
88
94
White balance adj.
89
7A
8A
3F
Contrast adj.
8B
3F
VG Center adj.
8C
Fixed data-1 (Initialized data)
8D
Fixed data-2
8E to 9F
Fixed data-1 (Initialized data)
A0
80
Video sync level adj.
A1 to A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
4.
D Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
Address
Initial value
Remark
10 to 20
Fixed data-1 (Initialized data)
21
00
Test mode
22 to 73
Fixed data-1 (Initialized data)
COVER
COVER
DSC-P7
6-9
1-2-2.
Initialization of B, E, F, 7, 9 Page Data
1.
Initializing B, E, F, 7, 9 Page Data
Note:
If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Camera system adjustments
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
6
03
0E
3
6
00
2D
4
6
01
2D
Press PAUSE button.
5
6
02
Check the data changes to “01”.
6
Perform “Modification of B,
E, F, 7, 9 page Data”.
2.
Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 6D
Fixed data-1 (Initialized data)
6E
Fixed data-2
6F to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 5F
Fixed data-1 (Initialized data)
60
Fixed data-2
61 to 95
Fixed data-1 (Initialized data)
96
Fixed data-2
97 to FF
Fixed data-1 (Initialized data)
DSC-P7
6-10
5.
F Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
FF
AF Ilumination check.
11
FF
12
FF
13
FF
14
FF
15
FF
16, 17
Fixed data-1 (Initialized data)
18
36
Flange back adj.
19
54
1A
87
1B
71
1C
10
1D
C0
1E
00
1F
00
20
00
21
00
22
00
23
00
24
20
25
20
26
13
27
46
28
0A
29
00
2A
00
2B
00
2C
00
2D
00
2E
00
2F
00
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
Address
Initial value
Remark
3E
FF
Flange back adj.
3F
Fixed data-1 (Initialized data)
40
00
Flange back adj.
41
00
42
00
43
00
44
00
45
00
46
00
47
00
48
00
49
00
4A
00
4B
00
4C
00
4D
00
4E
00
4F
00
50
00
51
00
52
00
53
00
54 to 5D
Fixed data-1 (Initialized data)
5E
00
F No. compensation
5F
00
60
00
61
00
62
00
63
00
64
00
65
30
Light value adj.
66
FE
67
6D
68 to 6D
Fixed data-1 (Initialized data)
6E
00
Mixed color calcel adj.
6F
00
70
32
AWB 3200K standard data input 1
71
B2
72
23
73
64
74
32
75
6C
76
23
77
88
78
33
AWB 3200K standard data input 2
79
36
Page of 45
Display

Click on the first or last page to see other DSC-P7 (serv.man4) service manuals if exist.