DOWNLOAD Sony DSC-P7 (serv.man4) Service Manual ↓ Size: 477.34 KB | Pages: 45 in PDF or view online for FREE

Model
DSC-P7 (serv.man4)
Pages
45
Size
477.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p7-sm4.pdf
Date

Sony DSC-P7 (serv.man4) Service Manual ▷ View online

DSC-P7
6-15
Picture Frame Setting
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Oscilloscope and monitor TV
Specified Value
A=B, C=D, E=F
Note 1:
Displayed data of the page 1 of adjusting remote com-
mander.
1:XX:XX
YL data
YH data
Switch setting
1) FOCUS (Menu setting) .............................. MULTI AF
2) MACRO (Control button) .......................... ON
Setting method:
Order Page Address Data
Procedure
1
Shoot the color bar chart
with the zoom WIDE end.
2
Enter the output of VIDEO
OUT to the monitor TV, and
move the position as shown
in Fig. 6-1-15.
3
Horizontal width of one color
(B, C) and that of black (A,
D) on the color bar chart
should be same. (See Fig. 6-
1-13)
4
With vertical width of black
(E, F) set in same, the color
bar chart should come to the
center of monitor TV. (See
Fig. 6-1-14)
5
Check that the color bar on
the monitor TV is focused.
6
0
03
22
7
1
Note down the YH and YL
data. (Note 1)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
How to reset the zoom and focus when they deviated:
Order Page Address Data
Procedure
1
6
2C
01
2
6
90
00
3
6
91
Set the following data.
00: WIDE end
04: TELE end
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to
“01”.
8
6
01
00
Press PAUSE button.
Note 2:
The data noted down at step 7 of “Setting method”.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-13
2. Vertical period
Fig. 6-1-14
Check on the monitor TV
Fig. 6-1-15
A=B
C=D
A
B
C
D
Color bar chart picture frame
Monitor TV picture frame
E=F
V
E
F
DSC-P7
6-16
1.
Flange Back Adjustment
(Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 40 to 53
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Fig. 6-1-16
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
6
01
13
Press PAUSE button.
3
6
01
27
Press PAUSE button.
(Note 5)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 5:
The adjustment data will be automatically input to page:
F, address: 18 to 3E and 40 to 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
3
Perform “Flange Back
Check”.
[Precaution on Replacing the Video Lens or the SY-77
Board]
The DSC-P7 uses the position sensor to detect the zoom position.
Accordingly, the zoom position will vary if the position data
changes due to the replacement of the video lens or the SY-77
board, thus causing the video lens to collide against the mecha-
nism end when the power is turned off.
Though the position data is calibrated at the “Flange Back Adjust-
ment”, add the following work when making an adjustment at the
replacement of video lens to prevent a collision of video lens.
When Replacing the Video Lens
1) With current video lens assembled, turn the power on, and set
the bit value of Bit0 on Page:9, Address:17 to “0” using the
adjusting remote commander, then turn the power off.
2) Replace the video lens with a new one, turn the power on, and
perform the “Flange Back Adjustment”.
Thus, new position data will be written.
3) After the “Flange Back Adjustment”, return the bit value of
Bit0 on Page:9, Address:17 to “1” using the adjusting remote
commander.
When Replacing the SY-77 Board
1) Replace the SY-77 board with a new one, set the mode dial to
“PLAY”, turn the power on, and set the bit value of Bit0 on
Page:9, Address:17 to “0” using the adjusting remote com-
mander, then turn the power off.
2) Set the mode dial to “CAMERA”, turn the power on, and per-
form the “Flange Back Adjustment”.
Thus, new position data will be written.
3) After the “Flange Back Adjustment”, return the bit value of
Bit0 on Page:9, Address:17 to “1” using the adjusting remote
commander.
RadarW
RadarW
RadarW
RadarW
RadarW
DSC-P7
6-17
2.
Flange Back Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the flange back adjustment chart)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
 Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 40 to 53
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Precaution on Replacing the Video Lens or the
SY-77 board”. (See page 6-16)
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
6
01
13
Press PAUSE button.
3
6
01
15
Press PAUSE button.
(Note 3)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 3:
The adjustment data will be automatically input to page:
F, address: 18 to 3E and 40 to 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
3
Perform “Flange Back Check”.
3.
Flange Back Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
2
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
4
B
3D
Note down the data.
5
B
3D
50
Press PAUSE button.
6
Shoot the Siemens star with
the zoom TELE end.
7
Turn on the auto focus.
8
Check that the lens is
focused.
9
6
2C
01
10
While observe the TV
monitor, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
B
3D
Set data noted down at step
4, and press PAUSE button.
3
Release the data setting
performed at step 3.
(Refer to page 6-14)
DSC-P7
6-18
4.
F No. Compensation
RadarW
RadarW
RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
BB
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
5.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
AD
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
Page of 45