Sony DSC-P7 (serv.man4) Service Manual ▷ View online
DSC-P7
6-19
6.
Light Value Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 20 to 45
AE level 2: 20 to 45
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
setting”.
(Refer to page 6-15)
3
6
01
0D
Press PAUSE button.
(Note 4)
(Note 4)
4
6
02
Check the data changes to
“01”.
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
(Note 2) satisfies the AE
level 1 specified value.
7
F
65
Check that the displayed data
satisfies the AE level 2
specified value.
satisfies the AE level 2
specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 65 to 67.
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
7.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
6E and 6F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
setting”.
(Refer to page 6-15)
3
7
22
Note down the data.
4
7
22
00
Press PAUSE button.
5
6
01
D7
Press PAUSE button.
6
6
01
D5
Press PAUSE button.
(Note 2)
(Note 2)
7
6
02
Check the data changes to
“01”.
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 6E and 6F.
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
22
Set the data noted down at
step 3, and press PAUSE
button.
step 3, and press PAUSE
button.
3
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
DSC-P7
6-20
8.
Auto White Balance 3200K Standard Data Input 1
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end and
TELE end)
(Standard picture frame with the
zoom lens at WIDE end and
TELE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 6-15)
setting”. (WIDE end)
(Refer to page 6-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
5D
Note down the data.
6
7
5D
00
Press PAUSE button.
7
7
9D
Note down the data.
8
7
9D
80
Press PAUSE button.
9
6
37
01
10
6
01
11
Press PAUSE button.
11
6
38
Check the data changes to
“01”.
“01”.
12
6
01
C1
Press PAUSE button. (Note 3)
13
6
02
Check the data changes to
“01”.
“01”.
14
7
5D
Set data noted down at step 5,
and press PAUSE button.
and press PAUSE button.
15
7
9D
Set data noted down at step 7,
and press PAUSE button.
and press PAUSE button.
16
6
01
00
Press PAUSE button.
17
Perform “Picture Frame
setting”. (TELE end)
(Refer to page 6-15)
setting”. (TELE end)
(Refer to page 6-15)
18
6
37
02
19
6
01
0B
Press PAUSE button. (Note 3)
20
6
02
Check the data changes to
“01”.
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 70 to 77, B0, B2 and B4.
F, address: 70 to 77, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
DSC-P7
6-21
9.
Auto White Balance 3200K Standard Data Input 2
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
78 to 7F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
setting”. (Refer to page 6-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
04
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 78 to 7F.
F, address: 78 to 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
10. Auto White Balance 3200K Standard Data Input 3
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
80 to 87
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
setting”. (Refer to page 6-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
06
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 80 to 87.
F, address: 80 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
DSC-P7
6-22
11. Auto White Balance 3200K Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Specified Value
R ratio: 3E00 to 4200
B ratio: 3E00 to 4200
R-Y level data: 7E to 82
B-Y level data: 7E to 82
Y level data: 10 to 40
B ratio: 3E00 to 4200
R-Y level data: 7E to 82
B-Y level data: 7E to 82
Y level data: 10 to 40
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 6-15)
setting”. (WIDE end)
(Refer to page 6-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
5D
Note down the data.
6
7
5D
00
Press PAUSE button.
7
7
9D
Note down the data.
8
7
9D
80
Press PAUSE button.
9
6
37
0D
10
6
01
11
Press PAUSE button.
11
6
38
Check the data changes to
“01”.
“01”.
12
6
01
C1
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
“01”.
14
0
03
04
15
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
(Note 2) satisfied the R ratio
specified value.
16
0
03
05
17
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
(Note 2) satisfied the B ratio
specified value.
18
0
03
2C
19
1
Check that the R-Y level data
(Note 2) satisfied the
specified value.
(Note 2) satisfied the
specified value.
20
0
03
2D
21
1
Check that the B-Y level data
(Note 2) satisfied the
specified value.
(Note 2) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
5D
Set data noted down at step
5, and press PAUSE button.
5, and press PAUSE button.
3
7
9D
Set data noted down at step
7, and press PAUSE button.
7, and press PAUSE button.
4
0
03
00
5
6
37
00
6
6
B6
Set data noted down at step
3, and press PAUSE button.
3, and press PAUSE button.
7
F
74
Check that the displayed data
76
the Y level specified value.
7C
7E
7E
84
86
86
8
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
Click on the first or last page to see other DSC-P7 (serv.man4) service manuals if exist.