DSC-P51/P51M
5-33
3. VCO Adjustment (PK-062 Board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 7 of CN903 (HSY)
Measuring Instrument
Frequency counter
Adjustment Page
A
Adjustment Address
82 (NTSC Mode)
83 (PAL Mode)
Specified Value
T = 15734 
±
 30 Hz (NTSC Mode)
T = 15625 
±
 30 Hz (PAL Mode)
Menu setting:
1) VIDEO OUT of SET UP setting
.................................. NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
13
(NTSC Mode)
3
4
1D
82
(PAL Mode)
Change the data and set the
4
A
82
frequency (f) to the NTSC
 specified value.
5
A
82
Press PAUSE button.
Change the data and set the
6
A
83
frequency (f) to the PAL
specified value.
7
A
83
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
(NTSC Mode)
2
4
1D
80
(PAL Mode)
3
0
01
00
4.
D Range Adjustment (PK-062 Board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN903 (VG)
External trigger: Pin 8 of
CN903 (PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
85
Specified Value
A = 2.95 
±
 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
03
4
A
85
Change the data and set the
voltage (A) to the specified
value. (Note)
5
A
85
Press PAUSE button.
Note:
Adjust it between data 00 and 3F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
A
2H 
Pedestal 
Pedestal
A: Pedestal level difference between 1H period and
previous 1H period.
Fig. 5-1-18
DSC-P51/P51M
5-34
Fig. 5-1-20
A
2H
6. V-COM Level Adjustment (PK-062 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN903
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
87
Specified Value
A = 5.42 
± 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
03
4
A
87
Change the data and set the PSIG
signal level (A) to the specified
value.
5
A
87
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
2H
A
Pedestal
10 steps peak
A: Between the pedestal and 10 steps peak
5. Contrast Adjustment (PK-062 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN903 (VG)
External trigger: Pin 8 of CN903
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
8A
Specified Value
A = 2.65 
± 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
03
Change the data and set the
4
A
8A
voltage (A) to the specified
value. (Note)
5
A
8A
Press PAUSE button.
Note:
Adjust it between data 00 and 7F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
Fig. 5-1-19
DSC-P51/P51M
5-35
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
7.
V-COM DC Adjustment (PK-062 Board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on the LCD screen
Measuring Instrument
Adjustment Page
A
Adjustment Address
84
Specified Value
Shake the set from side to side
and check that no stripe lines can
be seen in the blue back image.
Note 1:
Perform “Bright Adjustment” and “Contrast Adjustment”
before this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
82
4
A
84
Change the data so that
brightness of the section A
and section B is equal.
5
A
84
Read the data and this data is
named Dref.
6
Convert Dref to decimal
notation, and obtain Dref’.
(Note 2)
7
Calculate D
84
’ using
following equations.
(decimal calculation)
D
84
’ = Dref’ – 10
8
Convert D
84
’ to a hexadeci-
mal number, and obtain D
84
.
(Note 2)
9
A
84
D
84
Press PAUSE button.
10
4
F1
07
11
Shake the set from side to
side and check that no stripe
lines can be seen on the LCD
screen. (Note 3)
12
A
84
Subtract 08 from the adjust-
ment value (D
84
) (Note 2)
13
A
84
Press PAUSE button.
14
Shake the set from side to
side and check that no stripe
lines can be seen on the LCD
screen. (Note 4)
Note 2:
 Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”.
Note 3:
 When any stripe lines are seen, perform the following
precedure.
Note 4:
 If any suitable value can not be found, input the value of
D
84
 and finish this adjustment.
Fig. 5-1-21
A
A
A
A
B
B
B
B
DSC-P51/P51M
5-36
8.
White Balance Adjustment (PK-062 Board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on the LCD screen
Measuring Instrument
Adjustment Page
A
Adjustment Address
88, 89
Specified Value
LCD screen must not be colored
Note 1:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC801
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
02
4
A
88
90
Press PAUSE button.
(Intital value)
5
A
89
83
Press PAUSE button.
(Intital value)
6
Check that the LCD screen is
not colored. If not colored,
proceed to “Processing after
Completing Adjustments”.
7
A
88
Change the data so that the
LCD screen is not colored.
89
(Note 2)
Note 2:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
0
01
00
Page of 99