DOWNLOAD Panasonic TH-42LF30ER / TH-47LF30ER Service Manual ↓ Size: 11.41 MB | Pages: 60 in PDF or view online for FREE

Model
TH-42LF30ER TH-47LF30ER
Pages
60
Size
11.41 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LA29 CHASSIS
File
th-42lf30er-th-47lf30er.pdf
Date

Panasonic TH-42LF30ER / TH-47LF30ER Service Manual ▷ View online

Service Manual
FULL HD LCD Display 
TH-42LF30ER  
TH-47LF30ER 
 
 
  LA29 Chassis 
 
 
Specifications
 
  
(Information in brackets [ ] refers to model 47”) 
 
 Power 
Source:
 
220-240V AC, 50/60 Hz 
 
 
Power Consumption: 
    Power on: 
 
290W  [340W] 
 
    Stand-by condition: 
0.5W  
 
    Power off condition: 
0.3W   
 
 
LCD Display panel:
 
 
L5EDDYY00335           [L5EDDYY00336] 
 
 
 
 
 
16:9 aspect ratio 
 
 
Screen size
   
Wight:  Height: 
  Diagonal: 
 
 
930mm         523mm          1,067mm 
 
 
[1,039mm]     [584mm]         [1,192mm]   
 
 
                    (No. of pixels) 
2,073.600 (1,920 (W) x 1,080 (H)) 
 
 
 
 
Operating Conditions: 
Temperature:    0°C 
 40°C 
 
 
     
Humidity: 
   20%  
 80%  
 
 
Applicable signals: 
 
         
Colour System:   
 
NTSC, PAL, PAL60, SECAM, NTSC 4.43, PAL M, PAL N 
 
 
     
Scanning Format:   
 
525 (480) / 60i, 60p  
 
 
 
 
 
625 (575) / 50i, 50p 
 
 
 
 
 
750 (720) / 60p, 50p  
 
 
 
 
 
1,125 (1,080) / 60i, 60p, 50i, 50p, 24p, 25p, 30p, 24sF 
 
 
               PC signals:   
 
VGA, SVGA, XGA, SXGA, UXGA ....(compressed) 
 
 
 
 
 
Horizontal scanning frequency 30 – 110 kHz 
 
 
 
 
 
Vertical scanning frequency 48 – 120 Hz 
 
 
 
 
 
 
 
 
 
 
 
 
 
             
Connection Terminals:
 
 
 
and 
ORDER No. PCZ1111133CE 
 
             
Connection Terminals: 
 
VIDEO IN 
BNC 
       1.0 Vp-p  (75
) 
 
       AUDIO L-R 
RCA Pin jack x 2 
       0.5 Vrms  
 
 
 
 
HDMI1, HDMI2 
Type A Connectors 
 
 COMPONENT/RGB 
IN: 
 
G/Y 
BNC 
       with sync 1.0 Vp-p (75
) 
 B/P
B
/C
BNC 
       0.7 Vp-p (75
) 
 R/P
R
/C
BNC 
       0.7 Vp-p (75
) 
 
       AUDIO L-R 
RCA Pin jack x 2 
       0.5 Vrms 
 
 
DVI-D IN 
DVI-D 24 Pin x 2 
       Compliance with DVI Revision 1.0 
 
 
Content Protection 
       Compatible with HDCP 1.1 
 
 
       AUDIO 
Stereo mini jack (M3) x 1 
        0.5 Vrms (Shared with PC IN) 
 
DVI-D OUT 
DVI-D 24 Pin x 2 
       Compliance with DVI Revision 1.0 
 
 
 
PC IN 
High-Density Mini D-sub 15PIN    G: with sync 1.0 Vp-p (75
) 
 
 
Pug & Play (VESA DDC 2B)          : without sync 0.7 Vp-p (75
) 
 
 
 
       B: 0.7 Vp-p (75
) 
 
 
 
       R: 0.7 Vp-p (75
) 
 
 
 
       HD/VD: 1.0-5.0 Vp-p (hight impedance) 
 
       AUDIO 
Stereo mini jack (M3) x 1 
        0.5 Vrms  (Shared with DVI-D IN) 
 
 
 
SERIAL IN 
External Control Terminal 
 
SERIAL OUT 
D-sub 9 Pin x 2 
        RS-232C compatible 
 
 SLOT 
2.0 
Yes 
 
 
Audio 
Output: 
   
10W (5W + 5W), 10% THD 
 
 
 
Accessories supplied : 
 
Remote Control 
 
2 x R6 (UM3)  Batteries 
 
 Dimensions: 
 
 
Width:         Height:        Depth:  
 
 
 
968mm        561mm       116mm 
 
 
[1,079mm]    [624mm]     [117mm] 
 
 
 
 
Weight:  
21 kg  
 
   
[25 
kg] 
 
 
Specifications are subject to change without notice. 
 
Mass and dimensions shown are approximate. 
 
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not 
contain warnings or cautions to advise non-technical individuals of potencial dangers in attempting to service a product. Products 
powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the 
product or products deal within this service information by anyone else could result in serious injury or death. 
Warning 
2
CONTENTS
SAFETY PRECAUTIONS ........................................... 4 
 GENERAL 
GUIDE LINES...................................... 4 
 
TOUCH – CURRENT CHECK............................... 4 
PREVENTION OF ELECTROSTATIC DISCHARGE 
(ESD) TO ELECTROSTATICALLY SENSITIVE (ES) 
DEVICES .................................................................... 5 
ABOUT LEAD FREE SOLDER (PBF)......................... 6 
 SUGGESTED 
PB 
FREE SOLDER ........................ 6 
APPLICABLE INPUT SIGNALS .................................. 7 
SERVICE HINTS ........................................................ 9 
CHASSIS BOARD LAYOUT ..................................... 10 
LOCATION OF LEAD WIRING ................................. 10 
OPERATING INSTRUCTIONS ................................. 11 
OPTION MENU......................................................... 12 
SERVICE MODE ...................................................... 13 
CAT (COMPUTER AIDED TEST) MODE ................. 13 
IIC MODE.................................................................. 13 
CD MODE ................................................................. 14 
SD MODE ................................................................. 14 
POWER LED BLINKING TIMING CHARD................ 18 
ADJUSTMENT METHOD.......................................... 19 
WIRING DIAGRAM ................................................... 20 
BLOCK DIAGRAM (1 OF 3) ...................................... 21 
PARTS LOCATION................................................... 24 
REPLACEMENT PARTS LIST.................................. 26 
SCHEMATIC DIAGRAMS ......................................... 40 
 
A-BOARD (1 OF 11) SCHEMATIC DIAGRAM .... 41 
 
DS-BOARD (1 OF 2) SCHEMATIC DIAGRAM.... 52 
 HX-BOARD 
SCHEMATIC DIAGRAM.................. 54 
 V1-BOARD 
SCHEMATIC DIAGRAM .................. 55 
 V2-BOARD 
SCHEMATIC DIAGRAM .................. 55 
CONDUCTOR VIEWS .............................................. 56 
 
 
 
 
 
 
MS MODE................................................................. 15 
ID MODE................................................................... 15 
IIC MODE STRUCTURE  ......................................... 16 
SELF CHECK ........................................................... 17 
3
Safety Precautions
General Guide Lines
1.  When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated 
or damaged by the short circuit. 
2.  After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly 
installed. 
3.  After servicing, make the following touch current checks to prevent the customer from being exposed to shock hazards. 
4.  Always ensure connector cover TKK5ZL50041 is correctly replaced before returning to customer (see Fig.1). 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
Touch-Current Check 
1.  Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 
2.  Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth 
ground such as a water pipe, as shown in Fig. 2. 
3.  Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network. 
4.  Check each exposed metallic part, and measure the voltage at each point. 
5.  Reserve the AC plug in the AC outlet and repeat each of the above measure. 
6.  The potential at any point (TOUCH CURRENT) expressed as voltage U1 and U2, does not exceed the following values: 
For a. c.: U1 = 35 V (peak) and U2 = 0.35 V (peak); 
For d. c.: U1 = 1.0 V, 
Note:
 
The limit value of U2 = 0.35 V (peak) for a. c. and U1 = 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 
2.0 mA d. c. 
The limit value U1 = 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 
kHz. 
7.  In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should 
be repaired and rechecked before it is returned to the customer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 2 
TO 
APPLIANCES 
EXPOSED 
METAL PARTS 
Resistance values in ohms (
) 
R
0
=500
 
R
S
=1500
 
C
S
=0.22
F 
10k
 
0.022
F 
COLD 
WATER PIPE 
(EARTH GROUND)
 
V: Voltmetr or oscilloscope 
  (r.m.s. or peak reading) 
Measuring network for TOUCH CURRENTS 
Input resistance: 
1M 
Input capacitance:
200pF 
Frequency range: 15Hz to 1MHz and d.c.respectively 
NOTE – Appropriate measures should be taken to obtain the correct value in case of non-sinusoidal waveforms 
U
2
 (V) 
Fig. 1 
U
1
 (V) 
  XTV3+10JFJK 
4
Page of 60
Display

Panasonic TH-42LF30ER / TH-47LF30ER Service Manual ▷ Download

  • DOWNLOAD Panasonic TH-42LF30ER / TH-47LF30ER Service Manual ↓ Size: 11.41 MB | Pages: 60 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic TH-42LF30ER / TH-47LF30ER in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic TH-42LF30ER / TH-47LF30ER TV. Information contained in Panasonic TH-42LF30ER / TH-47LF30ER Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.