Sony DSC-N1 (serv.man4) Service Manual ▷ View online
6-19
DSC-N1_ADJ
7) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-29
Note 2:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then per-
form readjustment.
setting is faulty. Check the picture frame, and then per-
form readjustment.
Fig. 6-1-30
8) Upon successful completion of the adjustment, the following
message is displayed. Click the
[OK]
button.
Fig. 6-1-31
4.
Color Shading Adjustment
[Adjustment method]
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
[Connect]
button to set the camera to the adjust-
ment mode.
Fig. 6-1-27
3) Adjust the mode switch of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Remove the 9 colors chart in the pattern box, and set the clear
chart.
Note 1:
At this time, nothing must be reflected in the clear
chart.
chart.
6) Click the
[Color Shading Adjustment]
button.
Fig. 6-1-28
6-20
DSC-N1_ADJ
5.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. Release of Data Setting during Camera Adj.
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the
1) Click the
[Start]
button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-24 to
Fig. 6-1-26 (See page 6-18), set the subject and click the
ing message is displayed, and then referring to Fig. 6-1-24 to
Fig. 6-1-26 (See page 6-18), set the subject and click the
[OK]
button.
Fig. 6-1-32
After that, the next message is displayed. Then, change the chart
in accordance with the message.
in accordance with the message.
Fig. 6-1-33
4) Click the
[OK]
button, and the items from “3. F No. Compen-
sation” to “7. Release of Data Setting during Camera Adj.”
will be executed.
will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK]
button.
Fig. 6-1-34
6-21
DSC-N1_ADJ
6.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
[Connect]
button to set the camera to the adjust-
ment mode.
Fig. 6-1-35
3) Adjust the mode switch of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the
[AWB 3200-5800K Standard Data Input]
button.
Fig. 6-1-36
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-37
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-38
7) Upon successful completion of the adjustment, the following
message is displayed. Click the
[OK]
button.
Fig. 6-1-39
6-22
DSC-N1_ADJ
7.
AWB (ND) 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
[Connect]
button to set the camera to the adjust-
ment mode.
Fig. 6-1-40
3) Adjust the mode switch of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the
[AWB$ND% 3200-5800K Standard Data Input]
but-
ton.
Fig. 6-1-41
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-42
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-43
7) Upon successful completion of the adjustment, the following
message is displayed. Click the
[OK]
button.
Fig. 6-1-44
8) Perform the “Camera Adjustment 4” successively without turn-
ing off the power switch of the camera.
Click on the first or last page to see other DSC-N1 (serv.man4) service manuals if exist.