DOWNLOAD Sony DSC-N1 (serv.man4) Service Manual ↓ Size: 578.35 KB | Pages: 36 in PDF or view online for FREE

Model
DSC-N1 (serv.man4)
Pages
36
Size
578.35 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-n1-sm4.pdf
Date

Sony DSC-N1 (serv.man4) Service Manual ▷ View online

6-23
DSC-N1_ADJ
8.
CAMERA Adjustment 4
Note:
After executing the “AWB (ND) 3200-5800K Standard Data
Input” perform the “CAMERA Adjustment 4” successively
without turning off the power switch of the camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. Color Reproduction Adj. & Check
4. Color Reproduction Adj. & Check (ND)
5. CCD Linearity Check
6. CCD White Defect Compensation Check
7. CCD Black Defect Compensation Check
8. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-24 to
Fig. 6-1-26 (See page 6-18), set the subject and click the 
[OK]
button.
Fig. 6-1-45
4) After that, “3. Color Reproduction Adj. & Check” and “4. Color
Reproduction Adj. & Check (ND)”will be executed. Upon
completion of adjustment, the check result is displayed on the
Color Reproduction Check screen.
Fig. 6-1-46
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG. (This screen and message are displayed 2 times during
execution of adjustment.)
Fig. 6-1-47
5) Upon successful completion of “4. Color Reproduction Adj.
& Check (ND)”, the following message is displayed. Change
the chart in accordance with the message.
Fig. 6-1-48
6) Click the 
[OK]
 button, and the items from “5. CCD Linearity
Check” to “8. Release of Data Setting during Camera Adj.”
will be executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-49
6-24
DSC-N1_ADJ
9.
CAMERA Adjustment 5
Note:
“CAMERA Adjustment 5” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “3. Preparing the Flash
Adjustment Box” (see page 6-9).)
Fig. 6-1-50
4) Press the 
[OK]
  button, and the “2. Strobe Adj.” will be ex-
ecuted.
5) During execution of “2. Strobe Adj.”, the following message
is displayed. After checking the flashing of strobe light, click
the 
[OK]
  button. (This message is displayed 4 times during
execution of adjustment.)
Fig. 6-1-51
6) Upon successful completion of “2. Strobe Adj.”, “3.Release
of Data Setting during CAMERA Adj.” is executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-52
10. CAMERA Adjustment 6
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Auto Focus Illumination Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “3. Preparing the Flash
Adjustment Box” (see page 6-9).)
Fig. 6-1-53
4) Press the 
[OK]
  button, and the “2. Auto Focus Illumination
check” will be executed.
5) Upon successful completion of the “2. Auto Focus Illumina-
tion Check”, the “3. Release of Data Setting during Camera
Adj.” will be executed successively.
6) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-54
6-25
DSC-N1_ADJ
1-5.
LCD  SYSTEM  ADJUSTMENTS
1-5-1.
Function of Each Button on LCD System
Adjustment Screen
Click the 
[LCD SYSTEM ADJUSTMENT]
  button on the Main
Menu screen, and the “LCD SYSTEM ADJUSTMENT” screen in
Fig. 6-1-55 will appear.
Fig. 6-1-55
1
[To Menu]
 button
The Main Menu screen comes back.
2
[Start]
 button
“LCD Adjustment” starts.
3
[Reset]
 button
This button functions same as the “Initialize” of the setup
screen.
4
[Release Data Setting]
 button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the LCD adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
4
3
2
1
1-5-2.
Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program executes the ad-
justment items if the LCD Adjustment Start button is clicked.
Button
Adjustment
Signal
Page
Address
Name
LCD
V-COM adj.
8F
11
Adjustment White Balance adj.
Arbitrary
8F
42, 43, 58, 59
Table 6-1-4
6-26
DSC-N1_ADJ
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the 
[OK]
 button.
Fig. 6-1-58
SEUS operation screen
Fig. 6-1-59
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-60
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj.”.
3) Upon successful completion of the “1. Data Setting during LCD
Adj.”, the following message is displayed during execution in
“2. V-COM Adj.”. On the SEUS screen, operate the UP/DOWN
key so that the brightness of portions A and B on the LCD
panel is equal. After the adjustment, click the 
[OK]
 button.
Fig. 6-1-56
4) Upon completion of “2. V-COM Adj.”, the following screen is
displayed during the execution of “3. White Balance Adj.”.
Check that the LCD screen is not colored. If colored, using the
[Up]
 / 
[Down]
 button on the screen, adjust so that the LCD
screen is not colored. After the adjustment, click the 
[End]
button in the screen.
Fig. 6-1-57
5) If the 
[End]
 button is clicked, “4. Release of Data Setting dur-
ing LCD Adj.” will be executed.
UP/DOWN key
A