Sony DSC-H400 Service Manual ▷ View online

DSC-H400
4-9
Adjustment order
Screen display
Setting Light Src value.
4-3-5. WB/AGC Adjustment
The WB/AGC (White Balance/Analog Gain Control) Adjustment 
order is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
LimitR:312 579
LimitB:338 628
MEAN G
DayLig
R Gain
G Gain
B Gain
25854
32018
25610
75923
Time:16585
Move OK...
OK
Fig. 4-3-13
The adjustment is complete.
The adjustment is finished abnormally.
LimitR:312 579
LimitB:338 628
MEAN G
DayLig
R Gain
G Gain
B Gain
26006
340
256
698
Time:26383
Move OK...
NG
Fig. 4-3-14
Malfunction of WB/AGC  
adjustment result
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “4-1-5. Setting the Adjustment Mode” (Page 4-3).
Confirm the indication
on the screen.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 4-3-14)
In this case, confirm the adjusting environment
and readjust. 
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “WB/AGC (LV10)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “4-1-6. Enabling the Adjustment” to enable the adjustment. (Page 4-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 4-3-13)
Press the “      (Playback)” button to return to 
adjustment menu.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item to “WB/AGC (LV10)”, 
and press the “       (Playback)” button. Press the Control button “ v ” “ V ” to change selected item 
to “Light Src”, and press the Control button “ b ” “ B ” to set the value as “00002”, and press the 
Control button “ z ”. (Fig. 4-3-12)
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 4-3-11)
Finished normally.
Finished abnormally.
Equipment required:  Small pattern box (PTB-1450)
Cover camera lens and 
Small pattern box (PTB-1450) (All black)
Clear chart
Small pattern box 
(PTB-1450)
5 mm or less (Wide end)
Black cloth
Camera
Fig. 4-3-11
Disable
00001
LightSrc
00002
P1RRatio
01078
P1BRatio
01031
P2RRatio
01478
P2BRatio
00635
Fig. 4-3-12
DSC-H400
4-10
4-3-6. MeShut26 Adjustment
The MeShut26 (Mechanical Shutter 26) Adjustment order is as fol-
lows.
Note:
Perform the MeShut26 Adjustment after those performed in 4-3-4 to 4-3-5.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Limit:420 480
CAPNUM :
DRAFT_G:
Iris No:
STILL_G:
MainDly:
SubDly :
54
60
1
473
644
20
1
Time:26545
OK
FINISH..
is
Fig. 4-3-16
The adjustment is complete.
Adjustment order
Screen display
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the indication other than that shown in
Fig. 4-3-16 appears on the screen, confirm the
adjusting environment and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut26 (LV13)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “4-1-6. Enabling the Adjustment” to enable the adjustment. (Page 4-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 4-3-16)
Press the “      (Playback)” button to return to 
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “4-1-5. Setting the Adjustment Mode” (Page 4-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 4-3-15)
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 4-3-15
DSC-H400
4-11
4-3-7. MeShut80 Adjustment
The MeShut80 (Mechanical Shutter 80) Adjustment order is as fol-
lows.
Note:
Perform the MeShut80 Adjustment after those performed in 4-3-4 to 4-3-6.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Limit:420 480
CAPNUM :
DRAFT_G:
Iris No:
STILL_G:
MainDly:
SubDly :
52
55
477
1068
4
1
Time:23747
482 480 478
OK
FINISH..
.
Fig. 4-3-18
The adjustment is complete.
The adjustment is finished abnormally.
...Iris or LV NG
CAPNUM :
DRAFT_G:
Iris No:
STILL_G:
MainDly:
SubDly :
66
0
Time:11638
482 478 476
Calib Er 
..
NG
Fig. 4-3-19
Malfunction of MeShut80 
adjustment result
Adjustment order
Screen display
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 4-3-19)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut80 (LV14)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “4-1-6. Enabling the Adjustment” to enable the adjustment. (Page 4-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 4-3-18)
Press the “      (Playback)” button to return to 
adjustment menu.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 4-3-17)
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “4-1-5. Setting the Adjustment Mode” (Page 4-3).
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 4-3-17
DSC-H400
4-12
Adjustment order
Screen display
4-3-8. Dark DP Adjustment
The Dark DP (Dead Pixel) Adjustment order is as follows.
Note:
Perform the Dark DP Adjustment after those performed in 4-3-4 to 4-3-7.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Cap Raw ...
Time(Sec)
DARK DPC
Threshold:
Find DP NUM
1
13
512
1
OK
FINISH....
+
Fig. 4-3-21
The adjustment is complete.
The adjustment is finished abnormally.
Cap Raw  ...
Threshold :
Find DP NUM
Time (Sec)
DARK DPC
602
99
41
1
FINISH  ....
NG
Fig. 4-3-22
Malfunction of Dark DP 
adjustment result
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally, 
the following indication appears on the screen.
(Fig. 4-3-22)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “Dark DPC (LV10)”, 
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “4-1-6. Enabling the Adjustment” to enable the adjustment. (Page 4-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears 
on the screen. (Fig. 4-3-21)
Press the “      (Playback)” button to return to 
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “4-1-5. Setting the Adjustment Mode” (Page 4-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 4-3-20)
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Clear chart
Small pattern box
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 4-3-20
Page of 40
Display

Click on the first or last page to see other DSC-H400 service manuals if exist.