Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h1-sm4.pdf
Date

Sony DSC-H1 (serv.man4) Service Manual ▷ View online

6-19
DSC-H1
6.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the AWB Adjustment Program (H1AwbAdjustment.exe).
2) Click the [Connect] button to set the camera to the adjustment
mode.
Fig. 6-1-34
3) Adjust the mode dial of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 4. Picture Frame Setting)
5) Click the [AWB 3200K-5800K Standard Data Input] button.
Fig. 6-1-35
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-36
Note: If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-37
7) Upon successful completion of the adjustment, the following
message is displayed. Click the [OK] button.
Fig. 6-1-38
8) Perform the “Camera Adjustment 4” successively without turn-
ing off the power switch of the camera.
6-20
DSC-H1
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-41
5) Upon successful completion of “3. Color Reproduction Adj.
& Check”, the following message is displayed. Change the
chart in accordance with the message.
Fig. 6-1-42
6) Click the [OK] button, and the items from “4. CCD Linearity
Check” to “7. Release of Data Setting during Camera Adj.”
will be executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
Fig. 6-1-43
7.
CAMERA Adjustment 4
Note: After executing the “AWB 3200-5800K Standard Data In-
put” perform the “CAMERA Adjustment 4” successively
without turning off the power switch of the camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. Color Reproduction Adj. & Check
4. CCD Linearity Check
5. CCD White Defect Compensation Check
6. CCD Black Defect Compensation Check
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-28 to
Fig. 6-1-30 (See page 6-17), set the subject and click the [OK]
button.
Fig. 6-1-39
4) After that, “3. Color Reproduction Adj. & Check” will be ex-
ecuted. Upon completion of adjustment, the check result is
displayed on the Color Reproduction Check screen.
Fig. 6-1-40
6-21
DSC-H1
8.
CAMERA Adjustment 5
Note: “CAMERA Adjustment 5” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Adj.
3. Auto Focus Illumination Check
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “3. Preparing the Flash
Adjustment Box” (see page 6-7).)
Fig. 6-1-44
4) Press the [OK] button, and the “2. Strobe Adj.” will be executed.
5) During execution of “2. Strobe Adj.”, the following message
is displayed. After checking the flashing of strobe light, click
the  [OK]  button. (This message is displayed 2 times during
execution of adjustment.)
Fig. 6-1-45
6) Upon successful completion of “2. Strobe Adj.”, “3. Auto Fo-
cus Illumination Check” is executed.
7) Upon successful completion of the “3. Auto Focus Illumina-
tion Check”, the “4. Release of Data Setting during Camera
Adj.” will be executed successively.
8) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK] button.
Fig. 6-1-46
6-22
DSC-H1
9.
CAMERA Adjustment 6
Note: Perform this adjustment only when replacing the lens block
or the angular velocity sensor. When the microprocessor,
circuit etc. is damaged, don’t perform this adjustment but
check the operations only.
[Precautions on the Parts Replacement]
There are two types of repair parts.
Type A: ECN-03MA
Type B: ECN-03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during steady shot operations. After replacing, re-adjust ac-
cording to the adjusting method after replacement.
[Precautions on Angular Velocity Sensor]
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
[Automatic Adjustment Program execution items and sequence]
1. Data Setting during Camera Adj.
2. HALL Sensor Gain Adj. (Vertical)
3. HALL Sensor Gain Adj. (Horizontal)
4. Angular Velocity Sensor Sensitivity Adj.
5. Release of Data Setting during Camera Adj.
[Measurement point of CAMERA Adjustment 6]
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope
[Adjusting method]
1) Select the mode (NTSC Mode or PAL Mode) with the Mode
Select radio button.
2) Click the [Start] button of the CAMERA Adjustment 6.
3) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
4) If “1. Data Setting during Camera Adj.” finished normally, the
following screen will be displayed. Operate this screen to per-
form “2. HALL Sensor Gain Adj. (Vertical)”.
Fig. 6-1-47
5) Click the [Measure the SV1 and SV2] button on the screen.
6) The following message will be displayed, and then set the sub-
ject in accordance with the message.
Fig. 6-1-48
Fig. 6-1-49
7) After setting the subject, click the [OK] button, and the follow-
ing message will be displayed. With the camera zoom at TELE
end, focus the subject by manual focusing operation.
Fig. 6-1-50
8) After that, the messages will be displayed in the following
order. Measure the SV2 and SV1 by observing the waveform
of the VIDEO terminal using an oscilloscope.
Fig. 6-1-51
9) Calculate a difference between SV2 and SV1, “SV2 - SV1”,
and enter that value in the entry block on the screen, and then
click the [OK] button.
White
White
Black
A4 size (297 mm 
× 210 mm)
Pattern A
Black
Page of 36