DOWNLOAD Sony DSC-H1 (serv.man4) Service Manual ↓ Size: 812.15 KB | Pages: 36 in PDF or view online for FREE

Model
DSC-H1 (serv.man4)
Pages
36
Size
812.15 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h1-sm4.pdf
Date

Sony DSC-H1 (serv.man4) Service Manual ▷ View online

6-11
DSC-H1
1-3.
VIDEO  SYSTEM  ADJUSTMENTS
1-3-1.
Function of Each Button on Video System
Adjustment Screen
Click the [VIDEO SYSTEM ADJUSTMENT] button on the Main Menu
screen, and the “VIDEO SYSTEM ADJUSTMENT” screen in Fig.
6-1-13 will appear.
Fig. 6-1-13
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs usd are displayed.
3
[Start] button
“Video Adjustment” starts.
4
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the video adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
1-3-2.
Adjustment Items of VIDEO System
Adjustment
The adjustment items of video system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program executes the ad-
justment items if the VIDEO Adjustment Start button is clicked.
Button
Adjustment
Signal
Page
Address
Name
VIDEO
VIDEO Output
Adjustment Level Adj.
Arbitrary
8F
D0
Table 6-1-2
5
4
3
2
1
6-12
DSC-H1
SEUS operation screen
Fig. 6-1-16
Check on the oscilloscope
Fig. 6-1-17
1-3-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Video Adj.
2. Video Output Level Adj.
3. Release of Data Setting during Video Adj.
[Specified value of video output level adj.]
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level:
A = 286 
± 5 mV (NTSC mode)
A = 300 
± 5 mV (PAL mode)
Burst level:
B = 286 
± 25 mV (NTSC mode)
B = 300 
± 25 mV (PAL mode)
[Adjusting method]
1) Click the [Start] button of the VIDEO Adjustment.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Video Adj.”.
3) If “1. Data Setting during Video Adj.” completed successfully,
the next message is displayed during the execution of “2. Video
Output Level Adj.”. Using the UP/DOWN key on the SEUS
Operation screen, adjust so that the sync level of the video
signals satisfies the specified value. After the adjustment, check
that the burst level of the video signals satisfies the specified
value, and click the [OK] button in the message.
Fig. 6-1-14
4) If the [OK] button button is clicked, “3. Release of Data Set-
ting during Video Adj.” will be executed.
5) Upon successful completion of all items of the VIDEO Ad-
justment, the following message is displayed. Click the [OK]
button.
Fig. 6-1-15
UP/DOWN key
H
A
B
6-13
DSC-H1
1-4.
CAMERA  SYSTEM  ADJUSTMENTS
1-4-1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-18 will appear.
Fig. 6-1-18
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 6” starts.
4
Mode Select radio button
Selects the mode to be adjusted.
5
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
6
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment 1-6. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
6
5
4
3
3
2
2
1
6-14
DSC-H1
1-4-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-3. The Automatic Adjustment Program divides the ad-
justment items into six, camera adjustment 1-6. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Button Name
Adjustment
Subject
Adjustment
Adjustment
Page
Address
(Note 1)
Wide Limit Adj.
Not required
6F
18, 19
Siemens star chart with ND filter
6D
A4 to AF, D0 to F7
CAMERA Adjustment 1
Flange Back Adj.
for minipattern box (Note 2) or
Flange back adjustment jig
6F
18 to 3F, 52, 53
Siemens star
_
_
CAMERA Adjustment 2
Flange Back Check
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation
6F
60 to 63, 6B to 6D
Measure Gain Adj.
Clear chart
6F
6B, 6F
CAMERA Adjustment 3
(Standard picture frame)
78
0C to 0F
Mechanical Shutter Adj.
6F
6B to 6D, B8 to BD,
C7 to C9
79
40 to 42, 45 to 47,
4A
Light Value Adj.
6F
65 to 67
AWB 3200K-5800K
9 colors chart
6E
00 to 21, 24 to 49
(Note 3)
Standard Data Input
(Standard picture frame)
Color Reproduction
9 colors chart
6E
60 to 67
Adj. & Check
(Standard picture frame)
CCD Linearity Check
_
 
 
 
         _
CAMERA Adjustment 4
CCD White Defect
Clear chart
_
_
Compensation Check
(Standard picture frame)
_
_
CCD Black Defect
Compensation Check
Strobe Adj.
6E
72 to 75
CAMERA Adjustment 5
Flash adjustment box (50 cm)
6F
D8 to EF
Auto focus illumination Check
6F
10 to 15
HALL Sensor Gain Adj.
Pattern A
CF
09
(Vertical)
(1.5 m from front the lens)
CAMERA Adjustment 6
HALL Sensor Gain Adj.
Pattern B
CF
0A
(Horizontal)
(1.5 m from front the lens)
Angular Velocity Sensor
Not required
CF
0B, 0C
Sensitivity Adj.
Note 1: The Automatic Adjustment Program does not support the “Wide Limit Adjustment”.
Note 2: Dark Siemens star chart.
Note 3: Use the AWB Adjustment Program (H1AwbAdjustment.exe).
Table 6-1-3