Sony DSC-F828 (serv.man4) Service Manual ▷ View online
6-19
DSC-F828
10. Light Value Adjustment
Adjust the standard LV value.
Adjust the standard LV value.
Mode
STILL (P AUTO) (P)
Subject
Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 0C, 0D
Measuring Instrument
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value1
0FE0 to 1020
Specified value2
40 to 60
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
during Camera System
Adjustments” is performed.
2
Check the picture frame. If
deviated, perform “5. or 6.
Picture Frame Setting”.
deviated, perform “5. or 6.
Picture Frame Setting”.
3
60
01
0D
Set the data.
4
Wait for 2 sec.
5
60
02
Read the data, and check it is
“01”. (Note2)
“01”. (Note2)
6
10
0C
Read the data, and this data is
named D
named D
0C
.
7
10
0D
Read the data, and this data is
named D
named D
0D
.
8
Calculate D
LV
using the
following equation
(Hexadecimal calculation)
D
(Hexadecimal calculation)
D
LV
= D
0C
×
100 + D
0D
10
Check that D
LV
satisfies the
specified value1.
11
6F
65
Read the data, and check it
satisfies the specified value2.
satisfies the specified value2.
Note2: The adjustment data will be automatically input to page: 6F,
address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
6-20
DSC-F828
11. Linear Matrix and AWB Adjustment
11-1.
Preparation (Get Reference Data)
In this work, acquire a reference data for the liner matrix adjustment
using a DSC-F828 camera that operates normally. And saves the
data in the inside of the PC. Therefore, if the same pattern box
and the same 9 colors chart are used, it is not necessary to
perform “Get Reference Data” again. The reference data
(GodRawData.CSV) is saved in the ProgramFiles\Sony\
F828C1MATRIX holder of the C drive.
using a DSC-F828 camera that operates normally. And saves the
data in the inside of the PC. Therefore, if the same pattern box
and the same 9 colors chart are used, it is not necessary to
perform “Get Reference Data” again. The reference data
(GodRawData.CSV) is saved in the ProgramFiles\Sony\
F828C1MATRIX holder of the C drive.
Mode
STILL (P AUTO) (P)
Subject
9 colors chart (PTB-1450)
(Standard picture frame)
About 6cm from the front of the lens
(Standard picture frame)
About 6cm from the front of the lens
Note1: When the reference data is acquired using a non-adjusted camera.
The linear matrix adjustment cannot be performed correctly.
Switch setting:
ZOOM .................................................................... WIDE end
MACRO ............................................................................ ON
FOCUS .................................................................. MANUAL
MACRO ............................................................................ ON
FOCUS .................................................................. MANUAL
Adjusting method:
1)
1)
Prepare a DSC-F828 camera that operates normally, and this
camera is named a reference camera.
camera is named a reference camera.
2)
Remove the camera under adjustment and installed the
reference camera instead.
reference camera instead.
3)
Set up the switches of the reference camera as above-mentioned.
4)
Shoot the 9 colors chart with the standard picture frame. (Refer
to “6. Picture Frame Setting (PTB-1450)”.
to “6. Picture Frame Setting (PTB-1450)”.
5)
Adjust the focus..
6)
Start the F828 C1 MATRIX ADJ on the PC.
7)
Click [Connect] on the F828 C1 MATRIX Adjustment screen.
8)
Click [Get Reference Data] of the file menu of the F828 C1
MATRIX Adjustment screen.
MATRIX Adjustment screen.
Note2: When the “File over write” message is displayed, a reference data
file (GodRawData.CSV) exists already in the Program Files\Sony\
F828C1MATRIX holder of the C drive. If you want to save this
file, rename it or move it to other holder.
F828C1MATRIX holder of the C drive. If you want to save this
file, rename it or move it to other holder.
Fig. 6-1-19.
9)
Acquisition of the reference data is performed automatically.
Note3: When the “Framing check” message is displayed, correct the
picture frame, and repeat from step 8).
Fig. 6-1-20.
10) When the “Completion of get reference data” message is
displayed. Click the [OK] button.
Fig. 6-1-21.
11) Remove the reference camera and installed the camera under
adjustment instead.
6-21
DSC-F828
11-2.
Linear Matrix and AWB Adjustment
This adjustment does the following adjustment items automatically.
Linear matrix adjustment
Compensate the dispersion of the linear matrix vale of the
CCD imager.
CCD imager.
AWB 3200K/5800K (Mon) standard data input
Acquire the white balance standard data at 3200K and 5800K
in monitoring mode.
in monitoring mode.
AWB 3200K/5800K (Cap) standard data input
Acquire the white balance standard data at 3200K and 5800K
in capture mode.
in capture mode.
Mode
STILL (P AUTO) (P)
Subject
9 colors chart (PTB-1450)
(Standard picture frame)
About 6cm from the front of the lens
(Standard picture frame)
About 6cm from the front of the lens
Adjustment Page
6E
Adjustment Address
80 to 9F (Linear matrix adjustment)
04 to 21, 24 to 49 (AWB 3200K/
5800K standard data input)
04 to 21, 24 to 49 (AWB 3200K/
5800K standard data input)
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
1)
1)
Install the camera for adjustment.
2)
Check that “1. Data Setting during Camera System Adjustments”
is performed.
is performed.
3)
Set up the switches of the reference camera as above-mentioned.
4)
Shoot the 9 colors chart with the standard picture frame. (Refer
to “6. Picture Frame Setting (PTB-1450)”.
to “6. Picture Frame Setting (PTB-1450)”.
5)
Adjust the focus..
6)
Start the F828 C1 MATRIX ADJ on the PC.
7)
Click [Connect] on the F828 C1 MATRIX Adjustment screen.
8)
Click [Linear Matrix and AWB Adjustment] on the F828 C1
MATRIX Adjustment screen.
MATRIX Adjustment screen.
Fig. 6-1-22.
9)
The following adjustments are performed automatically.
Linear matrix adjustment
AWB 3200K/5800K (Mon) standard data input
AWB 3200K/5800K (Cap) standard data input
Linear matrix adjustment
AWB 3200K/5800K (Mon) standard data input
AWB 3200K/5800K (Cap) standard data input
Note: When the “Framing check” message is displayed, correct the picture
frame, and repeat from step 7).
When the “File C:\ProgramFiles\Sony\F828C1MATRIX\
GodRawData.CSV can not be open” message is displayed, the
reference data file (GodRawData.CSV) for the liner matrix
adjustment is not in the inside of the PC. Therefore, perform “11-1.
Preparation (Get Reference Data)”.
GodRawData.CSV can not be open” message is displayed, the
reference data file (GodRawData.CSV) for the liner matrix
adjustment is not in the inside of the PC. Therefore, perform “11-1.
Preparation (Get Reference Data)”.
Fig. 6-1-23.
Fig. 6-1-24.
10) When the “Completion of adjustment” message is displayed.
Click the [OK] button.
Fig. 6-1-25.
11) If finish the camera system adjustments, release the data setting.
(See “1. Data Setting during Camera System Adjustments”.)
6-22
DSC-F828
12. Color Reproduction Check (CAP-Normal mode)
Adjust the color reproduction of yellow, red, blue and cyan so that
proper color reproduction is produced.
Adjust the color reproduction of yellow, red, blue and cyan so that
proper color reproduction is produced.
Mode
STILL (P AUTO) (P)
Subject
9 colors chart (PTB-1450)
Color bar chart (PTB-450)
(Standard picture frame)
Color bar chart (PTB-450)
(Standard picture frame)
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
NTSC vectorscope
Specified Value
Each center of six color luminance
points should settle within each color
reproduction frame.
points should settle within each color
reproduction frame.
Note: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
VIDEO OUT (SET UP setting) .................................... NTSC
VIDEO OUT (SET UP setting) .................................... NTSC
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
during Camera System
Adjustments” is performed.
2
Check the picture frame. If
deviated, perform “5. or 6.
Picture Frame Setting”.
deviated, perform “5. or 6.
Picture Frame Setting”.
3
7A
18
Read the data, and memorize it.
4
7A
18
00
Set the data.
5
60
37
39
Set the data.
6
60
01
AB
Set the data.
7
Wait for 1 sec.
8
Adjust the GAIN and PHASE of
the vectorscope so that the burst
luminance point is set at the
specified position.
the vectorscope so that the burst
luminance point is set at the
specified position.
9
Check that each center of six
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
7A
18
Set the data memorized at
“Adjusting method”.
“Adjusting method”.
3
Wait for 1 sec.
4
60
37
Read the data, and check it is “00”.
5
Perform “Color Reproduction
Check”.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
Check”.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
For CAP-Normal mode
Fig. 6-1-26.
Burst position
Click on the first or last page to see other DSC-F828 (serv.man4) service manuals if exist.