DOWNLOAD Sony DSC-F828 (serv.man4) Service Manual ↓ Size: 1.36 MB | Pages: 46 in PDF or view online for FREE

Model
DSC-F828 (serv.man4)
Pages
46
Size
1.36 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f828-sm4.pdf
Date

Sony DSC-F828 (serv.man4) Service Manual ▷ View online

6-15
DSC-F828
5. Picture Frame Setting (PTB-450)
Mode
STILL (P AUTO) (P)
Subject
Color bar chart and clear chart
(Standard picture frame)
About 20cm from the front of the lens
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=C=B/2, E=F
Switch setting:
ZOOM .................................................................... WIDE end
Setting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Shoot the color bar chart with
the zoom WIDE end.
3
Adjust the direction and distance
between the pattern box and
camera, and set the picture
frame to the specified position.
4
Adjust the focus.
5
Remove the color bar chart and
set the clear chart.
6
Check that the whole of the
screen is white. If not, adjust the
direction and distance slightly.
7
10
44
Read the data, and this data
named YH.
8
10
45
Read the data, and this data
named YL.
9
Perform the following
adjustments.
How to reset the focus when it deviated:
If the focus deviated due to some reason reset it in the following
method.
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
60
90
00
Set the data.
3
60
91
00
Set the data.
4
60
92
YL
Set the data. (Note)
5
60
93
YH
Set the data. (Note)
6
60
01
79
Set the data.
7
Wait until the movement of the
lens stops.
8
60
07
Read the data, and check it is “01”.
9
60
01
00
Set the data.
Note: YH and YL are the data read in the “Setting method”.
Check on an oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
E=F
V
E
F
Color bar chart picture frame
Effective picture frame
A
B
C
B
A
C
A = C =
B
2
6-16
DSC-F828
6. Picture Frame Setting (PTB-1450)
Mode
STILL (P AUTO) (P)
Subject
9 colors chart and clear chart
(Standard picture frame) (Note1)
About 6cm from the front of the lens
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=B/3
Note1: Check that the transparent window is in the lower right.
Switch setting:
ZOOM .................................................................... WIDE end
Setting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Shoot the 9 colors chart with
the zoom WIDE end.
3
Adjust the direction and distance
between the pattern box and
camera, and set the picture
frame to the specified position.
4
Adjust the focus.
5
Remove the 9 colors chart and
set the clear chart.
6
Check that the whole of the
screen is white. If not, adjust the
direction and distance slightly.
7
10
44
Read the data, and this data
named YH.
8
10
45
Read the data, and this data
named YL.
9
Perform the following
adjustments.
How to reset the focus when it deviated:
If the focus deviated due to some reason reset it in the following
method.
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
60
90
00
Set the data.
3
60
91
00
Set the data.
4
60
92
YL
Set the data. (Note2)
5
60
93
YH
Set the data. (Note2)
6
60
01
79
Set the data.
7
Wait until the movement of the
lens stops.
8
60
07
Read the data, and check it is “01”.
9
60
01
00
Set the data.
Note2: YH and YL are the data read in the “Setting method”.
Check on an oscilloscope
1. Horizontal period
Fig. 6-1-13.
2. Vertical period
Fig. 6-1-14.
Check on the monitor TV (Underscanned mode)
on the LCD screen
Fig. 6-1-15.
B
A
A
A = B
C
C
B
V
C =
B
3
A
A = B
C
C
C14 : Filter for AWB 5800K adjustment
Effective picture frame
Transparent window
White
Green
Yellow
W14
Red
Magenta
Cyan
Blue
B
C14
C =
B
3
A
2
B
A
6-17
DSC-F828
7. Color Shade Check
7-1.
Installing the “F828 C1 MATRIX ADJ”
Install the adjustment software “F828 C1 MATRIX ADJ” in the
PC.
System requirements of the PC:
OS
: Windows98/98SE/Me/2000/XP
RAM : Recommend 256MB or higher
USB : USB2.0 or USB1.1 (USB2.0 is recommended. Two USB
connectors are required.)
Installing the “F828 C1 MATRIX ADJ”:
1)
Extract “828matrix.zip” file and obtain “Setup.exe” file.
2)
Start up the “Setup.exe” and install the “F828 C1 MATRIX
ADJ”.
Note1: Contact our service headquarter of each area how to get the
“828matrix.zip” file.
Note2: For “F828 C1 MATRIX ADJ” adjustment software’s operating,
the following two conditions need to be satisfied.
• The application for adjustment (SEUS) is already installed in
the PC.
• The PC is equipped with the HASP key.
7-2.
Color Shade Check
Compensate the color shade.
Mode
STILL (P AUTO) ( P )
Subject
Clear chart (PTB-1450)
(Standard picture frame)
About 6cm from the front of the lens
Adjustment Page
6F
Adjustment Address
06, 07
Note1: Check that there are no reflections on the clear chart.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
1)
Check that “1. Data Setting during Camera System
Adjustments” is performed.
2)
Start the F828 C1 MATRIX ADJ on the PC.
3)
Click [Connect] on the F828 C1 MATRIX Adjustment screen.
If the connection is normal, the F828 C1 MATRIX Adjustment
screen will be as shown in bellow, indicating the “connected”
state
4)
Check that the picture frame is the standard picture frame.
5)
Click [Color Shading Adjustment] on the F828 C1 MATRIX
Adjustment screen.
Fig. 6-1-16.
6)
Color shading adjustment is performed automatically.
Fig. 6-1-17.
7)
When the  “Completion of adjustment” message is displayed.
Click the [OK] button.
Fig. 6-1-18.
8)
If finish the camera system adjustments, release the data setting.
(See “1. Data Setting during Camera System Adjustments”.)
6-18
DSC-F828
8. F No. Compensation
Adjusted the dispersion of the iris to every to every F number, and
compensate the exposure.
Mode
STILL (P AUTO) (P)
Subject
Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
60 to 64, 6B to 6D
Specified value
00
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame. If
deviated, perform “5. or 6.
Picture Frame Setting”.
3
60
01
BB
Set the data.
4
Wait for 15 sec.
5
60
02
Read the data, and check it is
“01”. (Note2)
6
6F
6B
Read the data, and check it
satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F,
address: 60 to 64, 6B to 6D.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
9. Mechanical Shutter Adjustment
Adjust the dispersion of the opening/closing time and the closing
loss rate of the mechanical shutter. and compensate the exposure.
Mode
STILL (P AUTO) (P)
Subject
Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame. If
deviated, perform “5. or 6.
Picture Frame Setting”.
3
60
01
AD
Set the data.
4
Wait until the movement of the
shutter stops.
5
60
02
Read the data, and check it is
“01”. (Note2)
6
6F
6B
Read the data, and check it
satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F,
address: 6B to 6D, B8 to D7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
Page of 46
Display