DOWNLOAD Sony DSC-F505V (serv.man2) Service Manual ↓ Size: 9.58 MB | Pages: 109 in PDF or view online for FREE

Model
DSC-F505V (serv.man2)
Pages
109
Size
9.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-f505v-sm2.pdf
Date

Sony DSC-F505V (serv.man2) Service Manual ▷ View online

5-29
Fig. 5-1-23
A
2H
Green 
White 100%
A
2H 
10 steps peak
Pedestal
Fig. 5-1-22
6. Color Adjustment (HI-73 Board)
Set the color  saturation to the standard value.
If, deviated, the color will be dark or light.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN002 (VG) on
FK block
External trigger: Pin 8 of CN002
(PANEL COM) on FK block
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D1
Specified Value
A = 544 ± 50 mVp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 04.
3) Select page: D, address: D1, change the data and set the volt-
age (A) between the white 100% (Reference level) and green
to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
5. Contrast Adjustment (HI-73 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN002 (VG) on
FK block
External trigger: Pin 8 of CN002
(PANEL COM) on FK block
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D4
Specified Value
A = 3.31 ± 0.05 Vp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 03.
3) Select page: D, address: D4, change the data and set the volt-
age (A) between the pedestal and 10 steps peak to the speci-
fied value.
4) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
5-30
Fig. 5-1-24
A
2H
Fig. 5-1-25
A
A
A
A
B
B
B
B
7. V-COM Level Adjustment (HI-73 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN002 (PANEL COM)
on FK block
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D6
Specified Value
A = 6.30 ± 0.05 Vp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 03.
3) Select page: D, address: D6, change the data and set the V-
COM signal level (A) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
8. V-COM Adjustment (HI-73 Board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
D8
Specified Value
The brightness difference
between the section-A and
section-B is minimum
Note:
Perform “Bright Adjustment” and “Contrast Adjustment”
before this adjustment.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 01.
3) Select page: 2, address: 10, and set data: 02.
4) Select page: D, address: D8, change the data so that bright-
ness of the section A and section B is equal.
5) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 2, address: 10, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.
5-31
9. White Balance Adjustment (HI-73 Board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
D2, D3
Specified Value
LCD screen must not be colored
Note:
Check the white balance only when replacing the follow-
ing parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC803
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: 02.
3)
Select page: D, address: D2 and D3, and set the data to the
initial value.
Note:
 To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: D2 and D3 so that the LCD screen
is not colored.
Note:
 To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Address
D2
D3
Data
B9
B7
5-32
1-6.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1. Battery Down Adjustment
Set the battery end voltage.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
Mode
STILL
Subject
Arbitrary
Measurement Point
Displayed data of page: 2,
address: 52
Measuring Instrument
Adjusting remote commander
Adjustment Page
D
Adjustment Address
90 to 94
Connection:
1)  Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-26.
Fig. 5-1-26
CPC-9 jig
(J-6082-393-C)
DC power supply
(6.0 to 7.2 V DC)
18
18
1
1
Adjustment remote
commander
Regulated power supply 
(3.5 
±
 0.1 Vdc)
Digital voltmeter
CN001
1
3
DD-148 BOARD
DD-148 BOARD
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so
that the digital volt meter display is 3.5 ± 0.1 Vdc.
2)
Turn off the power supply.
3)
Turn the HOLD switch of the adjusting remote commander.
4)
Turn on the power supply.
5)
Insert the memory stick to the unit, and set the STILL mode.
6)
Set the FOCUS switch in MANUAL mode.
7)
Select page: 0, address: 01, and set data: 01.
8)
Decrease the output voltage of the regulated power supply
so that the digital voltmeter display is 3.00 ± 0.01 Vdc.
9)
Select page: 2, address: 52, read the data, and this data is
named Dref.
10) Select page: D, address: 90, set data Dref, and then press the
PAUSE button of adjusting remote commander.
11) Convert Dref to decimal notation, and obtain Dref’.
(Refer to Table 5-2-2. “Hexadecimal-decimal conversion
table”)
12) Calculate D
91
’, D
92
’, D
93
’ and D
94
’ using following equations
(decimal calculation), convert it to a hexadecimal number,
and input each adjustment address.
Address: 91
D
91
’ = Dref’+8
Address: 92
D
92
’ = Dref’+10
Address: 93
D
93
’ = Dref’+10
Address: 94
D
94
’ = Dref’+10
Note:
After setting each data, be sure to press the PAUSE
button.
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Page of 109
Display

Click on the first or last page to see other DSC-F505V (serv.man2) service manuals if exist.